Annual measured performance of building-integrated solar energy systems in demonstration low-energy solar house

被引:9
|
作者
Lee, Kyoung-ho [1 ]
Lee, Jin-kook [1 ]
Yoon, Eung-sang [1 ]
Joo, Moon-chang [1 ]
Lee, Soon-myoung [1 ]
Baek, Nam-choon [1 ]
机构
[1] Korea Inst Energy Res, New & Renewable Energy Res Div, Solar Thermal Lab, Taejon 305343, South Korea
关键词
Compilation and indexing terms; Copyright 2024 Elsevier Inc;
D O I
10.1063/1.4893467
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents the details of the output and efficiency of the annual performance of building-integrated solar energy systems for a solar water heating system and solar photovoltaic (PV) modules of a demonstration near-zero-energy solar house that was constructed on the campus of the Korea Institute of Energy Research. The thermal systems installed in the house were a solar water heating system with building-integrated solar collectors for water heating and for part of the space heating, and a ground-coupled heat pump for space cooling and part of the space heating. Solar PV modules were installed on the roof of the house. The performance of these systems was monitored for more than 1 yr. The annual efficiencies of the building's integrated solar collectors and solar PV were 22.8% and 10.9%, respectively. The total annual solar fraction of the solar heating system was 69.7%, with an annual solar heat production of 248kW h/m(2). This paper also focuses on the efficiency of the house's solar storage, based upon intentionally varied drainage of hot water from the storage tank. It was found that the thermal loss from the solar storage tank has a strong functional relationship with the thermal demand of the solar storage tank per unit volume. For example, when the hot water consumption was reduced by half during September, the thermal loss increased to more than 70%, which would otherwise have been around 30%. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] PROPAGATION OF LOW-ENERGY SOLAR ELECTRONS
    ANDERSON, KA
    MCFADDEN, JP
    LIN, RP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (04): : 542 - 542
  • [32] PROPAGATION OF LOW-ENERGY SOLAR ELECTRONS
    ANDERSON, KA
    MCFADDEN, JP
    LIN, RP
    GEOPHYSICAL RESEARCH LETTERS, 1981, 8 (07) : 831 - 834
  • [33] Optimal configurations of high-rise buildings to maximize solar energy generation efficiency of building-integrated photovoltaic systems
    Yang, Li
    Liu, Xiaodong
    Qian, Feng
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (08) : 1104 - 1125
  • [34] Electricity yield simulation for the building-integrated photovoltaic system installed in the main building roof of the Fraunhofer Institute for Solar Energy Systems ISE
    Sprenger, Wendelin
    Wilson, Helen Rose
    Kuhn, Tilmann E.
    SOLAR ENERGY, 2016, 135 : 633 - 643
  • [35] Modelling and simulation of Building-Integrated solar thermal systems: Behaviour of the system
    Lamnatou, Chr.
    Mondol, J. D.
    Chemisana, D.
    Maurer, C.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 45 : 36 - 51
  • [36] Measured performance of 12 demonstration projects - IEA Task 13 "advanced solar low energy buildings"
    Thomsen, KE
    Schultz, JM
    Poel, B
    ENERGY AND BUILDINGS, 2005, 37 (02) : 111 - 119
  • [37] Building integration of solar energy systems
    Hestnes, Anne Grete
    Solar Energy, 1999, 67 (04): : 181 - 187
  • [38] Building integration of solar energy systems
    Hestnes, AG
    SOLAR ENERGY, 1999, 67 (4-6) : 181 - 187
  • [39] Solar integrated energy system for a green building
    Zhai, X. Q.
    Wang, R. Z.
    Dai, Y. J.
    Wu, J. Y.
    Xu, Y. X.
    Ma, Q.
    ENERGY AND BUILDINGS, 2007, 39 (08) : 985 - 993
  • [40] Energy performance evaluation of a low-energy academic building
    Pless, Shanti D.
    Torcellini, Paul A.
    Petersen, John E.
    ASHRAE TRANSACTIONS 2006, VOL 112, PT 1, 2006, 112 : 295 - +