To measure an impedance magnetocardiogram (I-MCG) signal, we have developed a superconducting quantum interference device (SQUID) magnetometer with a room-temperature pickup coil. The pickup coil (30-mm diameter) is set outside the cryostat and is connected to the input coil in the SQUID. The noise level of the magnetometer is 90 fT Hz(-1/2) at 10 kHz. Using the magnetometer, we measured I-MCG signals (below 15 pT)-which were obtained by applying an ac current (10 kHz) with constant amplitude (7 mA, peak-to-peak) to a subject-from the heart.
引用
收藏
页码:596 / 599
页数:4
相关论文
共 50 条
  • [31] Characterization of directly coupled dual-superconducting quantum interference device magnetometer
    Wu, C.H.
    Chen, J.H.
    Jhan, F.J.
    Jeng, J.T.
    Yang, H.C.
    Journal of Applied Physics, 2008, 104 (07):
  • [32] Development of miniature diamond anvil cell for the superconducting quantum interference device magnetometer
    Mito, M. (mitohtap@mbox.nc.kyushu-u.ac.jp), 1600, Japan Society of Applied Physics (40):
  • [33] Biological immunoassay with high Tc superconducting quantum interference device (SQUID) magnetometer
    Enpuku, K
    Minotani, T
    IEICE TRANSACTIONS ON ELECTRONICS, 2001, E84C (01): : 43 - 48
  • [34] A miniature magnetometer based on the superconducting quantum interference device with direct readout electronics
    Polushkin, V
    Wallis, M
    Glowacka, D
    Matthews, A
    Lumley, JM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (03): : 1461 - 1464
  • [35] An ultra-sensitive and wideband magnetometer based on a superconducting quantum interference device
    Storm, Jan-Hendrik
    Hoemmen, Peter
    Drung, Dietmar
    Koerber, Rainer
    APPLIED PHYSICS LETTERS, 2017, 110 (07)
  • [36] Characterization of directly coupled dual-superconducting quantum interference device magnetometer
    Wu, C. H.
    Chen, J. H.
    Jhan, F. J.
    Jeng, J. T.
    Yang, H. C.
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (07)
  • [37] Improved superconducting quantum interference device magnetometer for low cross talk operation
    Granata, C.
    Vettoliere, A.
    Russo, M.
    APPLIED PHYSICS LETTERS, 2006, 88 (21)
  • [38] Development of miniature diamond anvil cell for the superconducting quantum interference device magnetometer
    Mito, M
    Hitaka, M
    Kawae, T
    Takeda, K
    Kitai, T
    Toyoshima, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (11): : 6641 - 6644
  • [39] Design and fabrication of low-noise superconducting quantum interference device magnetometer
    Han Hao-Xuan
    Zhang Guo-Feng
    Zhang Xue
    Liang Tian-Tian
    Ying Li-Liang
    Wang Yong-Liang
    Peng Wei
    Wang Zhen
    ACTA PHYSICA SINICA, 2019, 68 (13)
  • [40] Signatures of Room-Temperature Quantum Interference in Molecular Junctions
    Liu, Shi-Xia
    Ismael, Ali K.
    Al-Jobory, Alaa
    Lambert, Colin J.
    ACCOUNTS OF CHEMICAL RESEARCH, 2023, : 322 - 331