Comparative study of on-site corrosion monitoring for concrete by different methods

被引:1
|
作者
Fang, Xiang [1 ]
Chen, Long [1 ]
Pan, Jun [1 ]
机构
[1] CCCC Fourth Harbour Engn Inst Co Ltd, Guangzhou, Guangdong, Peoples R China
关键词
corrosion monitoring; anode ladder system; reference electrode; reinforced concrete; SENSOR;
D O I
10.4028/www.scientific.net/AMR.838-841.2066
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
As one of the key steps in the process of durability design and redesign, corrosion monitoring of reinforcement in concrete is of importance. To ensure the concrete durability of the quay structure, corrosion monitoring systems are utilized in Port Said East Container Terminal - Phase 2, Egypt. Embedded half-cell potential reference electrodes and anode ladder systems were used together. Early stage corrosion monitoring data in a precast slab is presented. Comparison of half-cell potential and anode ladder system data give some comprehensive understanding of the mechanism of the corrosion monitoring.
引用
收藏
页码:2066 / 2070
页数:5
相关论文
共 50 条
  • [41] On-site concrete waste minimization in the UK
    Meibodi, Amir B.
    Kew, H.
    CONSTRUCTION MATERIALS AND STRUCTURES, 2014, : 1352 - 1357
  • [42] ON-SITE MANAGEMENT OF PRECAST CONCRETE CONSTRUCTION
    FONDISTOUYANNAS, S
    JOST, DA
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1976, 21 (04): : 58 - 71
  • [43] CONCRETE CUT TO SIZE FOR ON-SITE ASSEMBLY
    不详
    INDUSTRIAL DIAMOND REVIEW, 1971, 31 (365): : 146 - &
  • [44] Diagnostic methods for transformers on-site
    Gockenbach, E
    Borsi, H
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 737 - 742
  • [45] Application of LPR and EIS techniques for on-site corrosion monitoring at the geothermal plant in Central Poland
    Ura-Binczyk, Ewa
    Dobkowska, Anna
    Andrzejczuk, Mariusz
    Roguska, Agata
    Mazurkiewicz, Boguslaw
    Solarski, Wojciech
    Balcer, Marek
    Lewandowska, Malgorzata
    Banas, Jacek
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2021, 72 (09): : 1518 - 1528
  • [46] Reinforced concrete structures: A review of corrosion mechanisms and advances in electrical methods for corrosion monitoring
    Rodrigues, Romain
    Gaboreau, Stephane
    Gance, Julien
    Ignatiadis, Ioannis
    Betelu, Stephanie
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 269
  • [47] On-site monitoring for better selection of stone repairs: a case study
    Thibault Demoulin
    Fred Girardet
    Timothy P. Wangler
    George W. Scherer
    Robert J. Flatt
    Heritage Science, 4
  • [48] On-site monitoring for better selection of stone repairs: a case study
    Demoulin, Thibault
    Girardet, Fred
    Wangler, Timothy P.
    Scherer, George W.
    Flatt, Robert J.
    HERITAGE SCIENCE, 2016, 4
  • [49] Structural performance and on-site monitoring of steel-concrete composite bridge with link slab
    Su, Hang
    Su, Qingtian
    Casas, Joan R.
    Wu, Huayong
    Liu, An
    Chen, Zhiquan
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2024, 20 (7-8) : 1197 - 1212
  • [50] Comparative study of two analytical methods to the determination of boron in leachate samples from sanitary landfills and groundwater for routine analysis and feasible on-site environmental monitoring
    Palma, Paulina
    Calderon, Raul
    Godoy, Marcelo
    Rubio, Maria A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (07) : 627 - 635