Three-dimensional delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5T and 3.0T

被引:73
|
作者
McKenzie, Charles A.
Williams, Ashley
Prasad, Pottumarthi V.
Burstein, Deborah
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Evanston NW Healthcare, Dept Radiol, Evanston, IL USA
关键词
dGEMRIC; cartilage; T1; arthritis; 3D;
D O I
10.1002/jmri.20689
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To implement and validate a three-dimension (31) T1 measurement technique that is suitable for delayed gadolinium (Gd)-enhanced MRI of cartilage (dGEMRIC) and can be easily implemented with clinically available pulse sequences at 1.5T and 3.0T. Materials and Methods: A 3D inversion-recovery prepared spoiled gradient-echo (IR-SPGR) imaging pulse sequence with variable TR was used to implement a 3D T1 measurement protocol. The 3D T1 measurements were validated against a gold-standard single-slice 2D IR T1 measurement protocol in both phantoms and in vivo, in both asymptomatic volunteers and volunteers with osteoarthritis (OA). Results: T1 measurements in phantoms showed a statistically significant correlation between the 2D and 3D measurements at 1.5T (R-2 = 0.993, P < 0.001) and 3.OT (R-2 = 0.996, P < 0.001). In vivo application demonstrated the feasibility of using this 3D IR-SPGR sequence to evaluate the molecular status of articular cartilage throughout the knee joint with 0.63 X 0.63 X 3.0 mm spatial resolution within a 20-minute acquisition, even with the measurement parameters set for the higher T1 (Gd) of cartilage at 3T (range = 400-900 msec mean T1 within a region of interest (ROI) in cartilage, compared to 200-600 msec mean T1 at 1.5T). Conclusion: This 3D T1 measurement protocol may prove useful for the evaluation and follow-up of cartilage dGEMRIC indices in clinical studies of OA.
引用
收藏
页码:928 / 933
页数:6
相关论文
共 50 条
  • [41] Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC):: Intra- and interobserver variability in standardized drawing of regions of interest
    Tiderius, CJ
    Tjörnstrand, J
    Åkeson, P
    Södersten, K
    Dahlberg, L
    Leander, P
    ACTA RADIOLOGICA, 2004, 45 (06) : 628 - 634
  • [42] Delayed Gadolinium-Enhanced MRI of Cartilage (dGEMRIC) of Cadaveric Shoulders: Comparison of Contrast Dynamics in Hyaline and Fibrous Cartilage after Intraarticular Gadolinium Injection
    Wiener, E.
    Hodler, J.
    Pfirrmann, C. W. A.
    ACTA RADIOLOGICA, 2009, 50 (01) : 86 - 92
  • [43] In vivo transport of Gd-DTPA2- into human meniscus and cartilage assessed with delayed gadolinium-enhanced MRI of cartilage (dGEMRIC)
    Sigurdsson, Ulf
    Siversson, Carl
    Lammentausta, Eveliina
    Svensson, Jonas
    Tiderius, Carl-Johan
    Dahlberg, Leif E.
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [44] In vivo transport of Gd-DTPA2- into human meniscus and cartilage assessed with delayed gadolinium-enhanced MRI of cartilage (dGEMRIC)
    Ulf Sigurdsson
    Carl Siversson
    Eveliina Lammentausta
    Jonas Svensson
    Carl-Johan Tiderius
    Leif E Dahlberg
    BMC Musculoskeletal Disorders, 15
  • [45] 氧增强肺MRI——1.5T和3.0T的个体内比较
    Thieme S F
    Dietrich O
    Maxien D
    黄璐
    放射学实践 , 2011, (05) : 556 - 556
  • [46] 宫颈癌:3.0T与1.5T MRI术前分期的比较
    M.Hori
    T.Kim
    T.Murakami
    I.Imaoka
    H.Onishi
    K.Tomoda
    陈柱
    国际医学放射学杂志, 2009, 32 (03) : 288 - 288
  • [47] Gadoxate-Enhanced T1-Weighted MR Cholangiography: Comparison of 1.5T and 3.0T
    Koelblinger, C.
    Schima, W.
    Weber, M.
    Mang, T.
    Nemec, S.
    Kulinna-Cosentini, C.
    Bastati, N.
    Ba-Ssalamah, A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (06): : 587 - 592
  • [48] Single- vs. double-dose gadolinium contrast in delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) in knee osteoarthritis: is dose reduction possible on 3-T MRI?
    Hangaard, Stine
    Gade, Jesper Soerensson
    Hansen, Philip
    Nybing, Janus Damm
    Gudbergsen, Henrik
    Bliddal, Henning
    Boesen, Mikael
    ACTA RADIOLOGICA, 2019, 60 (06) : 749 - 754
  • [49] WORSENING OF DELAYED GADOLINIUM-ENHANCED MRI OF CARTILAGE (dGEMRIC) INDICES OVER TIME IS ASSOCIATED WITH AN INCREASE IN CARTILAGE THICKNESS IN THE MEDIAL TIBIOFEMORAL COMPARTMENT IN A SAMPLE OF MIDDLE-AGED WOMEN: A 2-YEAR FOLLOW-UP STUDY USING 3.0T MRI
    Crema, M. D.
    Hunter, D. J.
    Burstein, D.
    Li, L.
    Krishna, N.
    Roemer, F. W.
    Eckstein, F.
    Le-Graverand, M-P. Hellio
    Guermazi, A.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 : S163 - S164
  • [50] A longitudinal study of the quantitative evaluation of patella cartilage after total knee replacement by delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) and T2 mapping at 3.0 T: preliminary results
    Kumahashi, N.
    Tadenuma, T.
    Kuwata, S.
    Fukuba, E.
    Uchio, Y.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (01) : 126 - 135