Glassy Carbon Electrode Modified with Layering of Carbon Black/Poly(Allylamine Hydrochloride) Composite for Multianalyte Determination

被引:8
|
作者
Scremin, Jessica [1 ,2 ]
Mattos, Gabriel J. [1 ]
Crapnell, Robert D. [2 ]
Rowley-Neale, Samuel J. [2 ]
Banks, Craig E. [2 ]
Sartori, Elen R. [1 ]
机构
[1] Univ Estadual Londrina, Ctr Ciencias Exatas, Dept Quim, Rodovia Celso Garcia Cid,PR 445 Km 380, BR-86057970 Londrina, Parana, Brazil
[2] Manchester Metropolitan Univ, Fac Sci & Engn, Chester St, Manchester M1 5GD, Lancs, England
关键词
simultaneous determination; modified electrode; voltammetry; polymer; complex samples; SPECTROPHOTOMETRIC DETERMINATION; ROSUVASTATIN CALCIUM; ELECTROCHEMICAL DETERMINATION; VOLTAMMETRIC DETERMINATION; LIQUID-CHROMATOGRAPHY; PARACETAMOL; AMLODIPINE; NANOTUBES; DOPAMINE; BLACK;
D O I
10.1002/elan.202060172
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensor using glassy carbon electrode modified with carbon black within a poly(allylamine hydrochloride) film is proposed in this work. The novel sensor was characterized by scanning electron microscopy, electrochemical impedance spectroscopy, and cyclic voltammetry using the redox probe Fe(CN)6(3-/4-). The sensor was applied for the simultaneous determination of dopamine (DA), paracetamol (PAR), amlodipine (AML), and rosuvastatin (RSV). The quantification of all four analytes was carried out by linear sweep voltammetry and presented a linear concentration range for all analytes from 1.0 to 90 mu mol L-1, with limit of detection of 0.55, 1.3, 5.7, and 3.0 mu mol L(-1)for DA, PAR, AML, and RSV, respectively. This sensor was successfully applied in the simultaneous determination of these analytes in environmental, pharmaceutical, and biological samples.
引用
收藏
页码:526 / 536
页数:11
相关论文
共 50 条
  • [21] Electrochemical determination of trace promethazine hydrochloride by a pretreated glassy carbon electrode modified with DNA
    Yang, Zhou-Sheng
    Zhao, Jun
    Zhang, Da-Peng
    Liu, Yun-Chun
    ANALYTICAL SCIENCES, 2007, 23 (05) : 569 - 572
  • [22] Voltammetric determination of hydroquinone using β-cyclodextrin/poly(N-acetylaniline)/carbon nanotube composite modified glassy carbon electrode
    Kong, Bo
    Yin, Tanji
    Liu, Xiaoying
    Wei, Wanzhi
    ANALYTICAL LETTERS, 2007, 40 (11) : 2141 - 2150
  • [23] Sensitive determination of adenine on poly(amidosulfonic acid)-modified glassy carbon electrode
    Zhang, Rui
    Jin, Gendi
    Hu, Xiaoya
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (10) : 1545 - 1552
  • [24] Electrochemical Determination of Amoxicillin on a Poly(Acridine Orange) Modified Glassy Carbon Electrode
    Agin, Fatma
    ANALYTICAL LETTERS, 2016, 49 (09) : 1366 - 1378
  • [25] Voltammetric determination of bisoprolol on a glassy carbon electrode modified by poly(arylene phthalide)
    Zil'berg, R. A.
    Yarkaeva, Yu. A.
    Sidel'nikov, A. V.
    Maistrenko, V. N.
    Kraikin, V. A.
    Gileva, N. G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (09) : 926 - 931
  • [26] Poly(amidosulfonic acid) modified glassy carbon electrode for determination of isoniazid in pharmaceuticals
    Yang, Gongjun
    Wang, Cunxiao
    Zhang, Rui
    Wang, Chenying
    Qu, Qishu
    Hu, Xiaoya
    BIOELECTROCHEMISTRY, 2008, 73 (01) : 37 - 42
  • [27] Voltammetric determination of catechol and hydroquinone at poly (murexide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Rani, T. Shobha
    Ganesh, P. S.
    Raj, Y. Paul
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 746 - 752
  • [28] Sensitive determination of adenine on poly(amidosulfonic acid)-modified glassy carbon electrode
    Rui Zhang
    Gendi Jin
    Xiaoya Hu
    Journal of Solid State Electrochemistry, 2009, 13 : 1545 - 1552
  • [29] Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode
    Xu, Guang-Ri
    Xu, Guifang
    Xu, Ming-Lu
    Zhang, Zhengqing
    Tian, Yuan
    Cho, Han Nim
    Lee, Won-Yong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (02): : 415 - 419
  • [30] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511