Cerenkov light spectrum in an optical fiber exposed to a photon or electron radiation therapy beam

被引:26
|
作者
Lambert, Jamil [1 ]
Yin, Yongbai [1 ]
McKenzie, David R. [1 ]
Law, Sue [1 ]
Suchowerska, Natalka [1 ,2 ]
机构
[1] Univ Sydney, Sch Phys, Sydney, NSW 2006, Australia
[2] Royal Prince Alfred Hosp, Dept Radiat Oncol, Camperdown, NSW 2050, Australia
关键词
DOSIMETER;
D O I
10.1364/AO.48.003362
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A Cerenkov signal is generated when energetic charged particles enter the core of an optical fiber. The Cerenkov intensity can be large enough to interfere with signals transmitted through the fiber. We determine the spectrum of the Cerenkov background signal generated in a poly(methyl methacrylate) optical fiber exposed to photon and electron therapeutic beams from a linear accelerator. This spectral measurement is relevant to discrimination of the signal from the background, as in scintillation dosimetry using optical fiber readouts. We find that the spectrum is approximated by the theoretical curve after correction for the wavelength dependent attenuation of the fiber. The spectrum does not depend significantly on the angle between the radiation beam and the axis of the fiber optic but is dependent on the depth in water at which the fiber is exposed to the beam. (C) 2009 Optical Society of America
引用
收藏
页码:3362 / 3367
页数:6
相关论文
共 50 条
  • [21] CERENKOV RADIATION PRODUCED BY MOTION OF AN ELECTRON BEAM THROUGH A DIELECTRIC TUBE
    BONCHOSMOLOVSKI.AG
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1963, 8 (03): : 217 - &
  • [22] ELECTRON-BEAM BUNCH PROFILE DETERMINATION THROUGH CERENKOV RADIATION
    MARUYAMA, XK
    NEIGHBOURS, JR
    BUSKIRK, FR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 1994 - 1996
  • [23] CERENKOV RADIATION FROM A RELATIVISTIC ELECTRON BEAM IN A CORRUGATED WAVEGUIDE.
    Aleksandrov, A.F.
    Galuzo, S.Yu.
    Kanavets, V.I.
    Pletyushkin, V.A.
    Slepkov, A.I.
    Soviet physics. Technical physics, 1980, 25 (11): : 1394 - 1398
  • [24] Electron Beam Spectrum Diagnostics with Optical Transition Radiation on the Beijing Free-Electron Laser
    李泉凤
    吴频
    高建江
    吴刚
    TsinghuaScienceandTechnology, 2004, (02) : 246 - 248
  • [25] Fiber-optic Cerenkov radiation sensor for proton therapy dosimetry
    Jang, Kyoung Won
    Yoo, Wook Jae
    Shin, Sang Hun
    Shin, Dongho
    Lee, Bongsoo
    OPTICS EXPRESS, 2012, 20 (13): : 13907 - 13914
  • [26] Optimization of photon beam flatness for radiation therapy
    Olofsson, J.
    Nyholm, T.
    Ahnesjo, A.
    Karlsson, M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S46 - S46
  • [27] Optimization of photon beam flatness for radiation therapy
    Olofsson, Jorgen
    Nyholm, Tufve
    Ahnesjo, Anders
    Karlsson, Mikael
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (06): : 1735 - 1746
  • [28] Impact of range uncertainties on robust mixed electron-photon beam radiation therapy
    Heng, V. J.
    Serban, M.
    Renaud, M.
    Seuntjens, J.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1768 - S1769
  • [29] IMPACT OF RANGE UNCERTAINTIES ON ROBUST MIXED ELECTRON-PHOTON BEAM RADIATION THERAPY
    Heng, Veng Jean
    Serban, Monica
    Renaud, Marc-Andre
    Seuntjens, Jan
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S116 - S117
  • [30] Scintillator-Based Motion Monitoring of Electron and Photon External Beam Radiation Therapy
    Huynh, Elizabeth
    Bhagwat, Mandar S.
    MEDICAL PHYSICS, 2018, 45 (06) : E179 - E179