Segmentation of bone CT images and assessment of bone structure using measures of complexity

被引:17
|
作者
Saparin, Peter
Thomsen, Jesper Skovhus
Kurths, Juergen
Beller, Gisela
Gowin, Wolfgang
机构
[1] Max Planck Inst Colloids & Intefaces, Dept Biomat, D-14424 Potsdam, Germany
[2] Univ Aarhus, Inst Anat, Dept Connect Tissue Biol, DK-8000 Aarhus C, Denmark
[3] Univ Potsdam, Inst Phys, Ctr Dynam Complex Syst, D-14469 Potsdam, Germany
[4] Univ Med Berlin, Charite, Dept Radiol, Ctr Muscel & Bone Res, D-12200 Berlin, Germany
[5] Hunter Imaging Grp, New Lambton, NSW 2305, Australia
关键词
image segmentation; bone structure; quantification; trabecular bone characterization; nonlinear dynamics; CT; trabecular bone; cortical bone;
D O I
10.1118/1.2336501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A nondestructive and noninvasive method for numeric characterization (quantification) of the structural composition of human bone tissue has been developed and tested. In order to quantify and to compare the structural composition of bones from 2D computed tomography (CT) images acquired at different skeletal locations, a series of robust, versatile, and adjustable image segmentation and structure assessment algorithms were developed. The segmentation technique facilitates separation of trabecular from cortical bone and standardizes the region of interest. The segmented images were symbol-encoded and different aspects of the bone structural composition were quantified using six different measures of complexity. These structural examinations were performed on CT images of bone specimens obtained at the distal radius, humeral mid-diaphysis, vertebral body, femoral head, femoral neck, proximal tibia, and calcaneus. In addition, the ability of the noninvasive and nondestructive measures of complexity to quantify trabecular bone structure was verified by comparing them to conventional static histomorphometry performed on human fourth lumbar vertebral bodies. Strong correlations were established between the measures of complexity and the histomorphometric parameters except for measures expressing trabecular thickness. Furthermore, the ability of the measures of complexity to predict vertebral bone strength was investigated by comparing the outcome of the complexity analysis of the CT images with the results of a biomechanical compression test of the third lumbar vertebral bodies from the same population as used for histomorphometry. A multiple regression analysis using the proposed measures including structure complexity index, structure disorder index, trabecular network index, index of a global ensemble, maximal L-block, and entropy of x-ray attenuation distribution revealed an excellent relationship (r = 0.959, r(2) = 0.92) between the measures of complexity and compressive bone strength. In conclusion, the image segmentation techniques and the assessment of bone architecture by measures of complexity have been successfully applied to analyze high-resolution peripheral quantitative computed tomography (pQCT) and CT images obtained from the distal radius, humeral mid-diaphysis, third and fourth lumbar vertebral bodies, proximal femur, proximal tibia, and calcaneus. The proposed approach is of broad interest as it can be applied for the quantification of structures and textures originating from different imaging modalities in other fields of science. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3857 / 3873
页数:17
相关论文
共 50 条
  • [21] Segmentation of Bone Metastasis in CT Images Based on Modified HED
    Song, Yuchan
    Lu, Huimin
    Kim, Hyoungseop
    Murakami, Seiichi
    Ueno, Midori
    Terasawa, Takashi
    Aoki, Takatoshi
    2019 19TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2019), 2019, : 812 - 815
  • [22] Three-dimensional segmentation of bone structures in CT images
    Böhm, G
    Knoll, C
    Colomer, VG
    Alcañiz-Raya, M
    Albalat, S
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 277 - 286
  • [23] Influence of segmentation on micro-CT images of trabecular bone
    Tassani, S.
    Korfiatis, V.
    Matsopoulos, G. K.
    JOURNAL OF MICROSCOPY, 2014, 256 (02) : 75 - 81
  • [24] Segmentation and Classification of Jaw Bone CT images using Curvelet based Texture features
    Reddy, T. K.
    Kumaravel, N.
    BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2010, 9 (01): : 33 - 43
  • [25] Fast segmentation of bone in CT images using 3D adaptive thresholding
    Zhang, J.
    Yan, C. -H.
    Chui, C. -K.
    Ong, S. -H.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2010, 40 (02) : 231 - 236
  • [26] Symbolic dynamics and measures of complexity to quantify cancellous bone structure
    Saparin, PI
    Gowin, W
    Kurths, J
    Felsenberg, D
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 621 - 624
  • [27] Automatic segmentation of the orbital bone in 3D maxillofacial CT images with Double-Bone-Segmentation Network
    Lee, Soyoung
    Lee, Min Jin
    Hong, Helen
    Shim, Kyu Won
    Park, Seongeun
    INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [28] Assessment of Transverse Isotropy in Clinical-Level CT Images of Trabecular Bone Using the Gradient Structure Tensor
    Larsson, David
    Luisier, Benoit
    Kersh, Mariana E.
    Dall'Ara, Enrico
    Zysset, Philippe K.
    Pandy, Marcus G.
    Pahr, Dieter H.
    ANNALS OF BIOMEDICAL ENGINEERING, 2014, 42 (05) : 950 - 959
  • [29] Assessment of Transverse Isotropy in Clinical-Level CT Images of Trabecular Bone Using the Gradient Structure Tensor
    David Larsson
    Benoît Luisier
    Mariana E. Kersh
    Enrico Dall’Ara
    Philippe K. Zysset
    Marcus G. Pandy
    Dieter H. Pahr
    Annals of Biomedical Engineering, 2014, 42 : 950 - 959
  • [30] Processing of vertebral CT-images and quantification of their structure by measures of complexity
    Saparin, PI
    Gowin, W
    Kurths, J
    Felsenberg, D
    APPLIED NONLINEAR DYNAMICS AND STOCHASTIC SYSTEMS NEAR THE MILLENNIUM, 1997, (411): : 347 - 352