Experimental and Monte Carlo simulated spectra of a liquid-metal-jet x-ray source

被引:4
|
作者
Marziani, M. [1 ,2 ]
Gambaccini, M. [1 ,2 ]
Di Domenico, G. [1 ,2 ]
Taibi, A. [1 ,2 ]
Cardarelli, P. [1 ,2 ]
机构
[1] Univ Ferrara, Dipartimento Fis & Sci Terra, I-44122 Ferrara, Italy
[2] Ist Nazl Fis Nucl, Sez Ferrara, I-44122 Ferrara, Italy
关键词
Liquid-jet anode; Monte Carlo simulation; Electron-impact ionization; MCNPX; PENELOPE; EGS5; SPECTROSCOPY;
D O I
10.1016/j.apradiso.2014.06.007
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A prototype x-ray system based on a liquid-metal-jet anode was evaluated within the framework of the LABSYNC project. The generated spectrum was measured using a CZT-based spectrometer and was compared with spectra simulated by three Monte Carlo codes: MCNPX, PENELOPE and EGS5. Notable differences in the simulated spectra were found. These are mainly attributable to differences in the models adopted for the electron-impact ionization cross section. The simulation that more closely reproduces the experimentally measured spectrum was provided by PENELOPE. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:32 / 36
页数:5
相关论文
共 50 条
  • [21] Monte Carlo simulation of x-ray spectra in mammography
    Ng, KP
    Kwok, CS
    Tang, FH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05): : 1309 - 1318
  • [22] Comparison of propagation- and grating-based x-ray phase-contrast imaging techniques with a liquid-metal-jet source
    Zhou, T.
    Lundstroem, U.
    Thuering, T.
    Rutishauser, S.
    Larsson, D. H.
    Stampanoni, M.
    David, C.
    Hertz, H. M.
    Burvall, A.
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [23] Monte Carlo simulation of X-ray spectra produced by Linac
    Permatasari, Intan Dyah Ayu
    Suharyana
    Riyatun
    [J]. 9TH INTERNATIONAL CONFERENCE ON PHYSICS AND ITS APPLICATIONS (ICOPIA), 2019, 1153
  • [24] Monte-Carlo simulations of X-ray binary spectra
    Leahy, DA
    [J]. 12TH KINGSTON MEETING : COMPUTATIONAL ASTROPHYSICS, 1997, 123 : 109 - 111
  • [25] Monte Carlo simulation of x-ray tube spectra with PENELOPE
    Jia, Pengxiang
    Xie, Yaoqin
    Bao, Shanglian
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 503 - 506
  • [26] Modeling and experimental investigation of x-ray spectra from a liquid metal anode x-ray tube
    David, B
    Thran, A
    Eckart, R
    [J]. X-RAY SOURCES AND OPTICS, 2004, 5537 : 45 - 56
  • [27] Monte Carlo modeling of the Xoft AXXENT™ x-ray source
    Rusch, T
    Bohm, T
    Rivard, M
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2017 - 2018
  • [28] Monte Carlo modelling of the Xoft AXXENT x-ray source
    Taylor, R. E. P.
    Yegin, G.
    Rogers, D. W. O.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2205 - 2205
  • [29] Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens
    Freed, Melanie
    Miller, Stuart
    Tang, Katherine
    Badano, Aldo
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 4944 - 4956
  • [30] Monte Carlo simulator for x-ray spectra analysis of GaAs detectors
    Cola, A
    Reggiani, L
    Vasanelli, L
    [J]. HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 392 - 399