Reproducibility and reliability of volumetric measurements of olfactory eloquent structures

被引:46
|
作者
Yousem, DM
Geckle, RJ
Doty, RL
Bilker, WB
机构
[1] UNIV PENN,MED CTR,CTR SMELL & TASTE,PHILADELPHIA,PA 19104
[2] UNIV PENN,MED CTR,DEPT BIOSTAT & EPIDEMIOL,PHILADELPHIA,PA 19104
[3] UNIV PENN,MED CTR,CTR CLIN EPIDEMIOL & BIOSTAT,PHILADELPHIA,PA 19104
关键词
brain; volume; MR; magnetic resonance (MR); volume measurement; phantoms;
D O I
10.1016/S1076-6332(97)80027-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The authors assessed the reliability and reproducibility of volumetric measurements of olfactory bulbs and tracts (OBTs) and temporal lobes (TLs) with magnetic resonance (MR) imaging. Methods. Repetitive MR imaging of two phantoms and OBTs and TLs of patients was performed. Regions of interest were manually drawn around the relevant structures, and their volumes were measured at workstations. Intra- and interobserver variability for the two readers were measured. Intraclass and Pearson correlation coefficients and mean percentage differences were calculated. Results. The measured phantom volumes were within 1.9%-12% of the true volumes with a variability of 15%. Intraclass and Pearson correlation coefficients were greater than or equal to 0.919 for measurements by a single reader and greater than or equal to 0.924 for measurements by different readers. The inter- and intraobserver variabilities were less than or equal to 4.2% for TL and 11.3%-14.6% for OBTs. Conclusion. Volumetric measurements of the olfactory apparatus can be reliably and accurately reproduced from MR images.
引用
收藏
页码:264 / 269
页数:6
相关论文
共 50 条
  • [21] Original report - Interobserver reproducibility of volumetric MR imaging measurements of plexiform neurofibromas
    Poussaint, TY
    Jaramillo, D
    Chang, YC
    Korf, B
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) : 419 - 423
  • [22] Volumetric measurements of subcortical structures in motor neurone disease
    Goursky, I.
    Rushkevich, Y.
    Likhachev, S.
    EUROPEAN JOURNAL OF NEUROLOGY, 2019, 26 : 827 - 828
  • [23] MR volumetric measurements of the myomatous uterus: Improved reliability of stereology over linear measurements
    Joe, Bonnie N.
    Suh, Jongdae
    Hildebolt, Charles F.
    Hovsepian, David M.
    Johnston, Brian
    Bae, Kyongtae T.
    ACADEMIC RADIOLOGY, 2007, 14 (04) : 455 - 462
  • [24] Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
    Dag Wormanns
    Gerhard Kohl
    Ernst Klotz
    Anke Marheine
    Florian Beyer
    Walter Heindel
    Stefan Diederich
    European Radiology, 2004, 14 : 86 - 92
  • [25] Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
    Wormanns, D
    Kohl, G
    Klotz, E
    Marheine, A
    Beyer, F
    Heindel, W
    Diederich, S
    EUROPEAN RADIOLOGY, 2004, 14 (01) : 86 - 92
  • [26] Volumetric measurements of subcortical structures in patients with temporal lobe epilepsy
    Seeck, M
    Dreifuss, S
    Lazeyras, F
    Andino, SG
    Spinelli, L
    Vingerhoets, FJG
    NEUROLOGY, 2001, 56 (08) : A265 - A265
  • [27] VOLUMETRIC AND DIMENSIONAL MEASUREMENTS OF VESTIBULAR STRUCTURES IN THE SQUIRREL-MONKEY
    IGARASHI, M
    OUCHI, T
    ALFORD, BR
    ACTA OTO-LARYNGOLOGICA, 1981, 91 (5-6) : 437 - 444
  • [28] Reproducibility of CMR right ventricle volumetric measurements is independent of reader experience under a standardized protocol
    Murilo Foppa
    Arman Ashrafi
    Carol J Salton
    Michael L Chuang
    Warren J Manning
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [29] Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty
    Mahmood, Sarwar S.
    Al-Amiry, Bariq
    Mukka, Sebastian S.
    Baea, Saida
    Sayed-Noor, Arkan S.
    SKELETAL RADIOLOGY, 2015, 44 (03) : 345 - 351
  • [30] Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty
    Sarwar S. Mahmood
    Bariq Al-Amiry
    Sebastian S. Mukka
    Saida Baea
    Arkan S. Sayed-Noor
    Skeletal Radiology, 2015, 44 : 345 - 351