Demonstration of enhanced K-edge angiography utilizing a samarium x-ray generator

被引:0
|
作者
Sato, Eiichi [1 ]
Tanaka, Etsuro [2 ]
Mori, Hidezo [3 ]
Kawai, Toshiaki [4 ]
Inoue, Takashi [5 ]
Ogawaf, Akira [5 ]
Izumisawa, Mitsuru [6 ]
Takahashi, Kiyomi [7 ]
Sato, Shigehiro [7 ]
Ichimaru, Toshio [8 ]
Takayama, Kazuyoshi [9 ]
机构
[1] Iwate Med Univ, Dept Phys, 3-16-1 Honchodori, Morioka, Iwate 0200015, Japan
[2] Tokyo Univ Agr, Fac Appl Biosci, Dept Nutr Sci, Setagaya Ku, Tokyo 1568502, Japan
[3] Natl Cardiovasc Ctr Hosp & Res Inst, Dept Cardiac Physiol, Osaka 5658565, Japan
[4] Hamamatsu Photon KK, Elect Tube Div 2, Iwata 4380193, Japan
[5] Iwate Med Univ, Sch Med, Dept Neurosurg, Morioka, Iwate 0208505, Japan
[6] Iwate Med Univ, Sch Dent, Dept Oral Radiol, Morioka, Iwate 0200021, Japan
[7] Iwate Med Univ, Sch Med, Dept Microbiol, Morioka, Iwate 0208505, Japan
[8] Hirosaki Univ, Sch Hlth Sci, Dept Radiol Technol, Hirosaki, Aomori 0368564, Japan
[9] Tohoku Univ, Biomed Engn Res Org, Sendai, Miyagi 9808577, Japan
基金
日本科学技术振兴机构;
关键词
K-series characteristic x-rays; samarium target; demountable x-ray tube; enhanced K-edge angiography;
D O I
10.1117/12.679234
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The samarium-target x-ray tube is useful in order to perform cone-beam K-edge angiography because K-series characteristic x-rays from the samarium target are absorbed effectively by iodine-based contrast media. This generator consists of the following components: a constant high-voltage power supply, a filament power supply, a turbomolecular pump, and an x-ray tube. The x-ray tube is a demountable diode which is connected to the turbomolecular pump and consists of the following major devices: a samarium target, a tungsten hairpin cathode (filament), a focusing (Wehnelt) electrode, a polyethylene terephthalate x-ray window 0.25 mm in thickness, and a stainless-steel tube body. In the x-ray tube, the positive high voltage is applied to the anode (target) electrode, and the cathode is connected to the tube body (ground potential). In this experiment, the tube voltage applied was from 50 to 70 kV, and the tube current was regulated to within 0.10 mA by the filament temperature. The exposure time is controlled in order to obtain optimum x-ray intensity. The electron beams from the cathode are converged to the target by the focusing electrode, and bremsstrahlung x-rays were absorbed using a 50-mu m-thick tungsten filter. The x-ray intensity was 1.04 mu Gy/s at 1.0 m from the x-ray source with a tube voltage of 60 kV and a tube current of 0.10 mA, and angiography was performed using a computed radiography system and iodine-based microspheres 15 mu m in diameter. In angiography of non-living animals, we observed fine blood vessels of approximately 100 gm with high contrasts.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Covalency in the actinides probed with ligand K-edge X-ray absoprtion spectroscopy
    Martin, Richard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [42] Fe K-EDGE X-RAY ABSORPTION SPECTROSCOPY OF SILICATE MINERALS AND GLASSES
    Binsted, N.
    Greaves, G. N.
    Henderson, C. M. B.
    JOURNAL DE PHYSIQUE, 1986, 47 (C-8): : 305 - 308
  • [43] MEASUREMENTS OF K-EDGE JUMP RATIOS WITH A LINEAR MOTION X-RAY SPECTROMETER
    HANSON, HP
    SCHRADER, HW
    PHYSICAL REVIEW, 1953, 91 (02): : 457 - 458
  • [44] CORRELATION OF X-RAY K-EDGE CHEMICAL-SHIFT AND BOND IONICITY
    LYTLE, FW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (03): : 488 - 488
  • [45] 53-attosecond X-ray pulses reach the carbon K-edge
    Li, Jie
    Ren, Xiaoming
    Yin, Yanchun
    Zhao, Kun
    Chew, Andrew
    Cheng, Yan
    Cunningham, Eric
    Wang, Yang
    Hu, Shuyuan
    Wu, Yi
    Chini, Michael
    Chang, Zenghu
    NATURE COMMUNICATIONS, 2017, 8
  • [46] Investigations of thyroglobulin clusters by X-ray absorption near edge spectroscopy at the S K-edge
    Schonschek, O
    Winter, I
    Hormes, J
    Herzog, V
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 : PH509 - PH509
  • [47] K-EDGE X-RAY ABSORPTION-SPECTRA FROM POTASSIUM COMPOUNDS
    SUGIURA, C
    MURAMATSU, S
    PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 1985, 132 (02): : K111 - K115
  • [48] Ligand K-edge x-ray absorption spectroscopy applied to bioinorganic systems
    Williams, KR
    Solomon, EI
    Hedman, B
    Hodgson, KO
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 756 - INOR
  • [49] X-ray absorption near-edge spectroscopy (XANES) at the phosphorus K-edge of triorganophosphinechalcogenides
    Engemann, C
    Franke, R
    Hormes, J
    Lauterbach, C
    Hartmann, E
    Clade, J
    Jansen, M
    CHEMICAL PHYSICS, 1999, 243 (1-2) : 61 - 75
  • [50] K-edge X-ray absorption spectra of argon in sputtered aluminum films
    Takemura, X
    Satake, H
    Yasuami, S
    Yoshiki, M
    Kitajima, Y
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (01) : 159 - 162