Virtual patients for mechanical ventilation in the intensive care unit

被引:49
|
作者
Zhou, Cong [1 ,2 ]
Chase, J. Geoffrey [2 ]
Knopp, Jennifer [2 ]
Sun, Qianhui [2 ]
Tawhai, Merryn [3 ]
Moller, Knut [4 ]
Heines, Serge J. [5 ]
Bergmans, Dennis C. [5 ]
Shaw, Geoffrey M. [6 ]
Desaive, Thomas [7 ]
机构
[1] Northwestern Polytech Univ, Sch Civil Aviat, Xian, Peoples R China
[2] Univ Canterbury, Dept Mech Engn, Christchurch, New Zealand
[3] Univ Auckland, Auckland Bioengn Inst ABI, Auckland, New Zealand
[4] Furtwangen Univ, Inst Tech Med, Villingen Schwenningen, Germany
[5] Maastricht Univ, Sch Med, Dept Intens Care, Maastricht, Netherlands
[6] Christchurch Hosp, Dept Intens Care, Christchurch, New Zealand
[7] Univ Liege, Inst Phys, GIGA In Silico Med, Liege, Belgium
基金
欧盟地平线“2020”;
关键词
Hysteresis model; Hysteresis loop analysis; Digital twins; Virtual patient; Mechanical ventilation; Lung mechanics; RESPIRATORY-DISTRESS-SYNDROME; END-EXPIRATORY PRESSURE; INDUCED LUNG INJURY; NONLINEAR AUTOREGRESSIVE MODEL; HIGH AIRWAY PRESSURE; RANDOM VIBRATION; RECRUITABILITY; IDENTIFICATION; MULTISCALE; GENERATION;
D O I
10.1016/j.cmpb.2020.105912
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background: Mechanical ventilation (MV) is a core intensive care unit (ICU) therapy. Significant inter- and intra- patient variability in lung mechanics and condition makes managing MV difficult. Accurate prediction of patient-specific response to changes in MV settings would enable optimised, personalised, and more productive care, improving outcomes and reducing cost. This study develops a generalised digital clone model, or in-silico virtual patient, to accurately predict lung mechanics in response to changes in MV. Methods: An identifiable, nonlinear hysteresis loop model (HLM) captures patient-specific lung dynamics identified from measured ventilator data. Identification and creation of the virtual patient model is fully automated using the hysteresis loop analysis (HLA) method to identify lung elastances from clinical data. Performance is evaluated using clinical data from 18 volume-control (VC) and 14 pressure-control (PC) ventilated patients who underwent step-wise recruitment maneuvers. Results: Patient-specific virtual patient models accurately predict lung response for changes in PEEP up to 12 cmH(2)O for both volume and pressure control cohorts. R-2 values for predicting peak inspiration pressure (PIP) and additional retained lung volume, V-frc in VC, are R-2 =0.86 and R-2 =0.90 for 106 predictions over 18 patients. For 14 PC patients and 84 predictions, predicting peak inspiratory volume (PIV) and V-frc yield R-2 =0.86 and R-2 =0.83. Absolute PIP, PIV and V-frc errors are relatively small. Conclusions: Overall results validate the accuracy and versatility of the virtual patient model for capturing and predicting nonlinear changes in patient-specific lung mechanics. Accurate response prediction enables mechanically and physiologically relevant virtual patients to guide personalised and optimised MV therapy. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] THE IMPACT OF DELIRIUM ON MECHANICAL VENTILATION IN THE PEDIATRIC INTENSIVE CARE UNIT
    Madden, Kevin
    Khemani, Robinder
    Gold, Jeffrey
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U99 - U99
  • [22] Strategies for the Use of Mechanical Ventilation in the Neurologic Intensive Care Unit
    Chang, Wan-Tsu W.
    Nyquist, Paul A.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2013, 24 (03) : 407 - +
  • [23] NONINVASIVE MECHANICAL VENTILATION IN THE OLDER PATIENT IN THE INTENSIVE CARE UNIT
    Ramirez-Alvarado, J. M.
    Magana-Macias, C.
    Olvera, C. I.
    Camarena-Alejo, G.
    Aguirre-Sanchez, J.
    Franco-Granillo, J.
    INTENSIVE CARE MEDICINE, 2011, 37 : S191 - S191
  • [24] Improving Mechanical Ventilation Weaning in a Medical Intensive Care Unit
    Salmon, Christine
    Stachowiak, Mary
    CRITICAL CARE NURSE, 2023, 43 (02) : E17 - E18
  • [25] PROLONGED MECHANICAL VENTILATION (PMV) IN PAEDIATRIC INTENSIVE CARE UNIT
    Pavalascu, A.
    Perez Quesada, S.
    Zazo Sanchidrian, C.
    Reig Saenz, R.
    INTENSIVE CARE MEDICINE, 2014, 40 : S280 - S280
  • [26] Mechanical Ventilation and Respiratory Support in the Pediatric Intensive Care Unit
    Alibrahim, Omar
    Rehder, Kyle J.
    Miller, Andrew G.
    Rotta, Alexandre T.
    PEDIATRIC CLINICS OF NORTH AMERICA, 2022, 69 (03) : 587 - 605
  • [27] Mechanical Ventilation in the Pediatric Cardiac Intensive Care Unit: The Essentials
    Rimensberger, Peter C.
    Heulitt, Mark J.
    Meliones, Jon
    Pons, Marti
    Bronicki, Ronald A.
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2011, 2 (04) : 609 - 619
  • [28] Withdrawal of mechanical ventilation in anticipation of death in the intensive care unit
    Cook, D
    Rocker, G
    Marshall, J
    Sjokvist, P
    Dodek, P
    Griffith, L
    Freitag, A
    Varon, J
    Bradley, C
    Levy, M
    Finfer, S
    Hamielec, C
    McMullin, J
    Weaver, B
    Walter, S
    Guyatt, G
    NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (12): : 1123 - 1132
  • [29] ALBUMIN CHANGES DURING MECHANICAL VENTILATION PREDICT OUTCOMES IN INTENSIVE CARE UNIT PATIENTS
    Kim, Seohyun
    An, Taijoon
    Park, Chan Kwon
    Yoon, Hyoung-Kyu
    RESPIROLOGY, 2019, 24 : 214 - 214
  • [30] Hemodynamic changes during discontinuation of mechanical ventilation in medical intensive care unit patients
    Frazier, Susan K.
    Stone, Kathleen S.
    Moser, Debra
    Schlanger, Rebecca
    Carle, Carolyn
    Pender, Lauren
    Widener, Jeanne
    Brom, Heather
    AMERICAN JOURNAL OF CRITICAL CARE, 2006, 15 (06) : 580 - 594