Torque sensing using amorphous magnetostrictive wires

被引:0
|
作者
Voliotis, S [1 ]
Christodoulou, G [1 ]
Hristoforou, A [1 ]
机构
[1] TEI Chalkis, Dept Elect Engn, Psahna 34400, Euboea, Greece
来源
关键词
torque sensors; amorphous magnetostrictive wires; MDL; stress-impedance; domain walls nucleation and propagation;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper we present experimental results on the torsional dependence of amorphous magnetostrictive wires by using three different magnetic techniques in order to evaluate and compare them, namely magnetostrictive delay line, the stress-impedance and the domain wall nucleation and propagation techniques. We determined monotonic response in the stress-impedance and domain wall nucleation and propagation set-ups even in the as cast form. Concerning the magnetostrictive delay line, induced magnetic anisotropy was required to obtain monotonic response. The most sensitive response was obtained by using the delay line technique, although the power consumption was higher.
引用
收藏
页码:671 / 675
页数:5
相关论文
共 50 条
  • [31] Sensitive stress sensor using amorphous magnetostrictive wires on both ends fixed double beam and diaphragm
    Shen, L.P.
    Naruse, Y.
    Kusumoto, D.
    Kita, E.
    Mohri, K.
    Uchiyama, T.
    Yoshinaga, T.
    IEEE Transactions on Magnetics, 1999, 35 (5 pt 2): : 3619 - 3621
  • [32] Sensitive stress sensor using amorphous magnetostrictive wires on both ends fixed double beam and diaphragm
    Shen, LP
    Naruse, Y
    Kusumoto, D
    Kita, E
    Mohri, K
    Uchiyama, T
    IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (05) : 3619 - 3621
  • [33] Mechanical torque in the ac field induced rotation of amorphous wires
    Borza, F
    Ovári, TA
    Meydan, T
    SENSORS AND ACTUATORS A-PHYSICAL, 2006, 129 (1-2) : 224 - 226
  • [34] Asymmetric torsion stress giant magnetoimpedance in nearly zero magnetostrictive amorphous wires
    Blanco, J.M.
    Zhukov, A.
    Gonzalez, J.
    1600, Am Inst Phys, Woodbury, NY, USA (87):
  • [35] Tensile stress measurements based on ΔE effect in positive magnetostrictive amorphous wires
    Chiriac, H
    Hristoforou, E
    Neagu, M
    EUROSENSORS XII, VOLS 1 AND 2, 1998, : 995 - 998
  • [36] New viscosimeter based on the ac field induced rotation of magnetostrictive amorphous wires
    Vázquez, M
    Castaño, FJ
    Ovári, TA
    Raposo, V
    Hernando, A
    SENSORS AND ACTUATORS A-PHYSICAL, 2001, 91 (1-2) : 112 - 115
  • [37] Asymmetric torsion stress giant magnetoimpedance in nearly zero magnetostrictive amorphous wires
    Blanco, JM
    Zhukov, A
    Gonzalez, J
    JOURNAL OF APPLIED PHYSICS, 2000, 87 (09) : 4813 - 4815
  • [38] MAGNETOSTRICTIVE TORQUE TRNASDUCER
    SCOPPE, FE
    INSTRUMENTATION TECHNOLOGY, 1969, 16 (10): : 95 - &
  • [39] Magnetostrictive torque transducers
    Justat, Jerzy
    Elektronika Warszawa, 1988, 29 (03): : 13 - 19
  • [40] Magnetostrictive accelerometer using amorphous metallic alloys
    Meydan, T
    Choudhary, P
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2002, 4 (02): : 261 - 266