Selective voltammetric and flow-injection determination of guanine and adenine on a glassy carbon electrode modified by a ruthenium hexachloroplatinate film

被引:7
|
作者
Shaidarova, L. G. [1 ]
Gedmina, A. V. [1 ]
Zhaldak, E. R. [1 ]
Chelnokova, I. A. [1 ]
Budnikov, G. K. [1 ]
机构
[1] Kazan Fed Univ, Butlerov Inst Chem, Kazan 420008, Russia
基金
俄罗斯基础研究基金会;
关键词
chemically modified electrodes; inorganic polymer films; ruthenium hexachloroplatinate; guanine; adenine; electrocatalysis; electroanalysis; flow-injection analysis; ELECTROCATALYTIC PROPERTIES; COMPOSITE FILM; ELECTROCHEMICAL PREPARATION; OXIDATION; DNA; NAD(+); ACIDS;
D O I
10.1134/S1061934814080097
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An inorganic film of ruthenium hexachloroplatinate (RuPtCl6), deposited on the surface of a glassy carbon electrode, exhibits electrocatalytic activity in the oxidation of purine bases, such as adenine and guanine. Appropriate working conditions are found for fabricating a polymer film on the surface of glassy carbon and for recording the maximum electrocatalytic effect for the modified electrode. A method is developed for the selective voltammetric determination of guanine and adenine in their simultaneous presence on an electrode modified by a RuPtCl6 film. A procedure is proposed for the amperometric detection of purine bases with this modified electrode under the conditions of flow-injection analysis. The dependence of the analytical signal on the concentration of guanine and adenine is linear up to 5 x 10(-6) and 5 x 10(-7) M in the stationary mode and to 5 x 10(-7) and 5 x 10(-8) M under flow conditions, respectively. The proposed method was tested in the analysis of calf thymus DNA for the concentrations of guanine and adenine.
引用
收藏
页码:741 / 749
页数:9
相关论文
共 50 条
  • [31] Simultaneous voltammetric determination of guanine and adenine by using a glassy carbon electrode modified with a composite consisting of carbon quantum dots and overoxidized poly(2-aminopyridine)
    Shaoying He
    Ping He
    Xiaojuan Zhang
    Xingquan Zhang
    Faqin Dong
    Lingpu Jia
    Licheng Du
    Hong Lei
    Microchimica Acta, 2018, 185
  • [32] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [33] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [34] FLOW-INJECTION DETERMINATION OF NOVALGIN USING AMPEROMETRIC DETECTION AT A GLASSY-CARBON ELECTRODE
    PEREZRUIZ, T
    LOZANO, CM
    TOMAS, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (09) : 1109 - 1113
  • [35] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Surface Engineering and Applied Electrochemistry, 2024, 60 : 15 - 23
  • [36] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984
  • [37] Voltammetric Determination of Guanine on the Electrode Modified by Gold Deposit and Nafion Film
    Shaidarova, L. G.
    Gedmina, A. V.
    Demina, V. D.
    Chelnokova, I. A.
    Budnikov, H. C.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2016, 158 (03): : 369 - 380
  • [38] Application of glassy carbon electrode modified with a carbon nanoparticle/melamine thin film for voltammetric determination of raloxifene
    Shahrokhian, Saeed
    Ghalkhani, Masoumeh
    Balotf, Hamed
    Salimian, Razieh
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 780 : 126 - 133
  • [39] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF NITROPRUSSIDE AT A GLASSY-CARBON ELECTRODE AND AT A SESSILE MERCURY DROP ELECTRODE
    FOGG, AG
    FERNANDEZARCINIEGA, MA
    ALONSO, RM
    ANALYST, 1985, 110 (04) : 345 - 348