The APV25 deep submicron readout chip for CMS detectors

被引:0
|
作者
Jones, LL [1 ]
French, MJ [1 ]
Morrissey, Q [1 ]
Neviani, A [1 ]
Raymond, M [1 ]
Hall, G [1 ]
Moreira, P [1 ]
Cervelli, G [1 ]
机构
[1] Rutherford Appleton Lab, Didcot OX11 0QX, Oxon, England
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The APV25 is a 128 channel analogue pipeline chip for readout of silicon microstrip detectors in the CMS tracker at the LHC. Each channel comprises a low noise amplifier, a 192 cell analogue pipeline and deconvolution readout circuit. Output data are transmitted on a single differential output via an analogue multiplexer. The chip is fabricated in a 0.25 micron CMOS process to take advantage of the radiation tolerance, lower noise;and power, and high circuit density which can be achieved.
引用
收藏
页码:162 / 166
页数:5
相关论文
共 50 条
  • [41] Radiation tolerance of the readout chip for the Phase I upgrade of the CMS pixel detector
    Hoss, J.
    Kaestli, H. -C.
    Meier, B.
    Rohe, T.
    Starodumov, A.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [42] Test beam campaigns for the CMS Phase I Upgrade pixel readout chip
    Spannagel, S.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [43] A radiation tolerant clock generator for the CMS endcap timing layer readout chip
    Sun, H.
    Sun, Q.
    Biereigel, S.
    Francisco, R.
    Gong, D.
    Huang, G.
    Huang, X.
    Kulis, S.
    Leroux, P.
    Liu, C.
    Liu, T.
    Liu, T.
    Moreira, P.
    Prinzie, J.
    Wu, J.
    Ye, J.
    Zhang, L.
    Zhang, W.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (03):
  • [44] Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection
    Sun, H.
    Gong, D.
    Zhang, W.
    Edwards, C.
    Huang, G.
    Huang, X.
    Liu, C.
    Liu, T.
    Olsen, J.
    Sun, Q.
    Wu, J.
    Ye, J.
    Zhang, L.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (06):
  • [45] GridPix: An integrated readout system for gaseous detectors with a pixel chip as anode
    van der Graaf, Harry
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1023 - 1026
  • [46] Readout chip with RISC-V microprocessor for hybrid pixel detectors
    Skrzypiec, P.
    Szczygiel, R.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (01):
  • [47] A system for multiplexed chip readout of double-sided silicon detectors
    Clemens, U
    Erven, W
    Gorke, H
    Kemmerling, G
    Maeckelburg, D
    Merzliakov, S
    Mussgiller, A
    Schleichert, R
    Zwoll, K
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 212 - 214
  • [48] SVX3: A deadtimeless readout chip for silicon strip detectors
    Zimmerman, T
    Huffman, T
    Srage, J
    Stroehmer, R
    Yarema, R
    Garcia-Sciveras, M
    Luo, L
    Milgrome, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 369 - 374
  • [49] THE GLUECHIP - A CUSTOM VLSI CHIP FOR DETECTORS READOUT AND ASSOCIATIVE MEMORIES CIRCUITS
    AMENDOLIA, SR
    GALEOTTI, S
    MORSANI, F
    PASSUELLO, D
    RISTORI, L
    SCIACCA, G
    TURINI, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 733 - 735
  • [50] SVX3: A deadtimeless readout chip for silicon strip detectors
    Fermi Natl Accelerator Lab, Batavia, United States
    Nucl Instrum Methods Phys Res Sect A, 1-3 (369-374):