Feasibility of non-invasive temperature estimation by the assessment of the average gray-level content of B-mode images

被引:13
|
作者
Teixeira, C. A. [1 ]
Alvarenga, A. V. [2 ]
Cortela, G. [3 ]
von Krueger, M. A. [4 ]
Pereira, W. C. A. [4 ]
机构
[1] Univ Coimbra, Dept Engn Informat, Ctr Informat & Sistemas, P-3030290 Coimbra, Portugal
[2] Natl Inst Metrol Standardizat & Ind Qual Inmetro, Lab Ultrasound, Duque De Caxias, Brazil
[3] Univ Republica, Lab Acust Ultrasonora, Fac Ciencias, Montevideo 11400, Uruguay
[4] Univ Fed Rio de Janeiro, COPPE, Biomed Eng Program, BR-21945 Rio De Janeiro, Brazil
关键词
Non-invasive temperature estimation; B-mode image processing; Average gray-level variation; ULTRASOUND; TISSUE; HYPERTHERMIA; DEPENDENCE; ENERGY;
D O I
10.1016/j.ultras.2014.02.021
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper assesses the potential of the average gray-level (AVGL) from ultrasonographic (B-mode) images to estimate temperature changes in time and space in a non-invasive way. Experiments were conducted involving a homogeneous bovine muscle sample, and temperature variations were induced by an automatic temperature regulated water bath, and by therapeutic ultrasound. B-mode images and temperatures were recorded simultaneously. After data collection, regions of interest (ROIs) were defined, and the average gray-level variation computed. For the selected ROIs, the AVGL-Temperature relation were determined and studied. Based on uniformly distributed image partitions, two-dimensional temperature maps were developed for homogeneous regions. The color-coded temperature estimates were first obtained from an AVGL-Temperature relation extracted from a specific partition (where temperature was independently measured by a thermocouple), and then extended to the other partitions. This procedure aimed to analyze the AVGL sensitivity to changes not only in time but also in space. Linear and quadratic relations were obtained depending on the heating modality. We found that the AVGL-Temperature relation is reproducible over successive heating and cooling cycles. One important result was that the AVGL-Temperature relations extracted from one region might be used to estimate temperature in other regions (errors inferior to 0.5 degrees C) when therapeutic ultrasound was applied as a heating source. Based on this result, two-dimensional temperature maps were developed when the samples were heated in the water bath and also by therapeutic ultrasound. The maps were obtained based on a linear relation for the water bath heating, and based on a quadratic model for the therapeutic ultrasound heating. The maps for the water bath experiment reproduce an acceptable heating/cooling pattern, and for the therapeutic ultrasound heating experiment, the maps seem to reproduce temperature profiles consistent with the pressure field of the transducer, and in agreement with temperature maps developed by COMSOL (R) MultiPhysics simulations. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1692 / 1702
页数:11
相关论文
共 33 条
  • [11] Dataset of human skin and fingernails images for non-invasive haemoglobin level assessment
    Yakimov, Boris
    Buiankin, Kirill
    Denisenko, Georgy
    Bardadin, Ilia
    Pavlov, Oleg
    Shitova, Yuliya
    Yuriev, Alexey
    Pankratieva, Lyudmila
    Pukhov, Alexander
    Shkoda, Andrey
    Shirshin, Evgeny
    SCIENTIFIC DATA, 2024, 11 (01)
  • [12] An Efficient Temperature Estimation Using Optical-Flow in Ultrasound B-Mode Digital Images
    Mehrabani, Bahram M.
    Tavakoli, Vahid
    Abolhassani, Mohammad D.
    Alirezaie, Javad
    Ahmadian, Alireza
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 86 - +
  • [13] Accuracy assessment of Tri-plane B-mode ultrasound for non-invasive 3D kinematic analysis of knee joints
    Md Abdullah Masum
    Mark Pickering
    Andrew Lambert
    Jennie Scarvell
    Paul Smith
    BioMedical Engineering OnLine, 13
  • [14] Accuracy assessment of Tri-plane B-mode ultrasound for non-invasive 3D kinematic analysis of knee joints
    Masum, Md Abdullah
    Pickering, Mark
    Lambert, Andrew
    Scarvell, Jennie
    Smith, Paul
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [15] Non-invasive colour Doppler and B-mode ultrasonography as valuable tools to study uterine involution in small ruminants
    Elmetwally, M.
    Meinecke-Tillmann, S.
    REPRODUCTION IN DOMESTIC ANIMALS, 2011, 46 : 13 - 14
  • [16] Maternal temperament and body condition score and their impact on ovine and caprine fetal development: assessment by b-mode and non-invasive color Doppler ultrasonography
    Elmetwally, M.
    Rohn, K.
    Meinecke-Tillmann, S.
    REPRODUCTION IN DOMESTIC ANIMALS, 2011, 46 : 101 - 101
  • [17] THE LIMITATIONS OF B-MODE IMAGING OF THE CAROTID BIFURCATION - A COMPARISON WITH 3 FLOW-DEPENDENT NON-INVASIVE TESTS
    LANE, RJ
    DART, LK
    APPLEBERG, M
    BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (659): : 817 - 820
  • [18] Does analysis of B-mode gray-scale images acquired with a US clinical system provide reliable estimation of attenuation?
    Morel, SCP
    Bridal, S
    Lucidarme, O
    Correas, J
    Berger, G
    RADIOLOGY, 2000, 217 : 395 - 395
  • [19] Non Invasive Assessment of Carotid and Femoral Arterial Pressure using B-Mode Ultrasound Diameter Waveforms
    Graf, Sebastian
    Craiem, Damian
    Armentano, Ricardo L.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 5610 - 5613
  • [20] Quantitative Interpretation of UWB Radar Images for Non-Invasive Tissue Temperature Estimation during Hyperthermia
    Prokhorova, Alexandra
    Ley, Sebastian
    Helbig, Marko
    DIAGNOSTICS, 2021, 11 (05)