Feasibility of non-invasive temperature estimation by the assessment of the average gray-level content of B-mode images

被引:13
|
作者
Teixeira, C. A. [1 ]
Alvarenga, A. V. [2 ]
Cortela, G. [3 ]
von Krueger, M. A. [4 ]
Pereira, W. C. A. [4 ]
机构
[1] Univ Coimbra, Dept Engn Informat, Ctr Informat & Sistemas, P-3030290 Coimbra, Portugal
[2] Natl Inst Metrol Standardizat & Ind Qual Inmetro, Lab Ultrasound, Duque De Caxias, Brazil
[3] Univ Republica, Lab Acust Ultrasonora, Fac Ciencias, Montevideo 11400, Uruguay
[4] Univ Fed Rio de Janeiro, COPPE, Biomed Eng Program, BR-21945 Rio De Janeiro, Brazil
关键词
Non-invasive temperature estimation; B-mode image processing; Average gray-level variation; ULTRASOUND; TISSUE; HYPERTHERMIA; DEPENDENCE; ENERGY;
D O I
10.1016/j.ultras.2014.02.021
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper assesses the potential of the average gray-level (AVGL) from ultrasonographic (B-mode) images to estimate temperature changes in time and space in a non-invasive way. Experiments were conducted involving a homogeneous bovine muscle sample, and temperature variations were induced by an automatic temperature regulated water bath, and by therapeutic ultrasound. B-mode images and temperatures were recorded simultaneously. After data collection, regions of interest (ROIs) were defined, and the average gray-level variation computed. For the selected ROIs, the AVGL-Temperature relation were determined and studied. Based on uniformly distributed image partitions, two-dimensional temperature maps were developed for homogeneous regions. The color-coded temperature estimates were first obtained from an AVGL-Temperature relation extracted from a specific partition (where temperature was independently measured by a thermocouple), and then extended to the other partitions. This procedure aimed to analyze the AVGL sensitivity to changes not only in time but also in space. Linear and quadratic relations were obtained depending on the heating modality. We found that the AVGL-Temperature relation is reproducible over successive heating and cooling cycles. One important result was that the AVGL-Temperature relations extracted from one region might be used to estimate temperature in other regions (errors inferior to 0.5 degrees C) when therapeutic ultrasound was applied as a heating source. Based on this result, two-dimensional temperature maps were developed when the samples were heated in the water bath and also by therapeutic ultrasound. The maps were obtained based on a linear relation for the water bath heating, and based on a quadratic model for the therapeutic ultrasound heating. The maps for the water bath experiment reproduce an acceptable heating/cooling pattern, and for the therapeutic ultrasound heating experiment, the maps seem to reproduce temperature profiles consistent with the pressure field of the transducer, and in agreement with temperature maps developed by COMSOL (R) MultiPhysics simulations. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1692 / 1702
页数:11
相关论文
共 33 条
  • [1] NON-INVASIVE ESTIMATION OF TEMPERATURE DURING PHYSIOTHERAPEUTIC ULTRASOUND APPLICATION USING THE AVERAGE GRAY-LEVEL CONTENT OF B-MODE IMAGES: A METROLOGICAL APPROACH
    Alvarenga, Andre V.
    Wilkens, Volker
    Georg, Olga
    Costa-Felix, Rodrigo P. B.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (09): : 1938 - 1952
  • [2] Non-invasive Temperature Assessment at Different Tissue Types Based on Average Grey-Level from B-Mode Ultrasonic Images
    Alvarenga, A. V.
    Teixeira, C. A.
    von Krueger, M. A.
    Pereira, W. C. A.
    INTERNATIONAL CONGRESS ON ULTRASONICS (GDANSK 2011), 2012, 1433 : 195 - 198
  • [3] Non-Invasive Assessment of Temperature Variation in Ex-vivo Renal Tissue by Tracking Average Grey-Level from B-Mode Images
    Alvarenga, Andre Victor
    Teixeira, Cesar A. D.
    von Krueger, M. A.
    Pereira, W. C. A.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1670 - 1673
  • [4] Non-invasive estimation of arterial pulse pressure from B-mode ecographic images
    Graf, S.
    Armentano, R.
    IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 355 - 359
  • [5] Uncertainty evaluation from non-invasive estimation of temperature variation using B-mode ultrasonic images from a plastic phantom
    Alvarenga, Andre Victor
    Domingues Teixeira, Cesar Alexandre
    von Krueger, Marco A.
    de Albuquerque Pereira, Wagner Coelho
    Costa-Felix, Rodrigo P. B.
    MEASUREMENT, 2015, 69 : 189 - 194
  • [6] Non-invasive assessment of arterial pulse pressure by using automatic analysis of B-mode echographic images
    Graf, S.
    Armentano, R.
    CIRCULATION, 2008, 118 (12) : E228 - E228
  • [7] Evaluation of the influence of large temperature variations on the grey level content of B-Mode images
    Alvarenga, Andre V.
    Teixeira, Cesar A.
    Ruano, Maria Graca
    Pereira, Wagner C. A.
    INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01): : 415 - 419
  • [8] Method for estimating average grey -level's measurement uncertainty from ultrasound images for non-invasive estimation of temperature in different tissue types
    Alvarenga, Andre, V
    Teixeira, Cesar A. D.
    von Kruger, Marco A.
    Pereira, Wagner C. A.
    ULTRASONICS, 2020, 106 (106)
  • [9] Influence of Temperature Variations on the Average Grayscale of B-mode Images of HIFU-Induced Lesions
    Marquez, S.
    Leija, L.
    Vera, A.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5983 - 5986
  • [10] NON-INVASIVE ASSESSMENT BY B-MODE ULTRASOUND OF ARTERIAL PULSE WAVE INTENSITY AND ITS REDUCTION DURING VENTRICULAR DYSFUNCTION
    Rowland, Ethan M.
    Riemer, K. A., I
    Lichtenstein, K. E. V. I. N.
    Tang, Meng-xing
    Weinberg, Peter D.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (02): : 473 - 488