Intraobserver variation in transvaginal Doppler blood flow measurements in benign ovarian tumors

被引:8
|
作者
Tekay, A
Jouppila, P
机构
[1] Dept. of Obstetrics and Gynecology, University of Oulu
[2] Dept. of Obstetrics and Gynecology, University of Oulu
关键词
Doppler velocimetry; measurement error; ovarian neoplasms; reliability;
D O I
10.1046/j.1469-0705.1997.09020120.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Intraobserver variation in transvaginal color Doppler ultrasound measurements in ovarian tumors was evaluated in 20 women selected from a group of patients undergoing surgical exploration for an ovarian lesion. Only those cases who were suspected of having a benign ovarian tumor other than a unilocular simple cyst were recruited. Pulsatility index (PI), resistance index (RI), peak systolic velocity (PSV) and time-averaged maximum velocity (TAMXV) were measured from intratumoral arteries in two repeat ultrasound sessions by the same observer. In each session, only two vessels with optimum Doppler signals were investigated. The repeatability of the measurements was studied by calculation of the within-subjects standard deviation (SD), the value below which the difference between the repeat measurements will lie with a probability of 0.95, the coefficient of variation (CV) and the intraclass correlation coefficient (intra-CC). The CV was 15% for the PI, 13% for the RI, 17% for the PSV and 23% for the TAMXV when the average value from two vessels was used. The corresponding intra-CC values were 0.86, 0.83, 0.96 and 0.90, respectively. In contrast, when a lowest (PI or RI) or a highest (PSV or TAMXV) value was preferred, the CV increased to 25% for the PI, to 18% for she RI, to 28% for the PSV and to 33% for the TAMXV. Similarly, the intra-CC values decreased. All in all, the averaged PI and RI measurements in intratumoral arteries were considered to be reliable. Averaged PSV and TAMXV measurements had high CV figures, raising some doubt as to the consistency of these variables. Averaged index values were more consistent than the extreme (lowest or highest) values.
引用
收藏
页码:120 / 124
页数:5
相关论文
共 50 条
  • [21] Comparison of uterine, endometrial and ovarian blood flow by transvaginal color Doppler ultrasound in ovulatory and anovulatory cycles
    Dogan, Ozan
    Yildiz, Ahmet
    Temizkan, Osman
    Pulatoglu, Cigdem
    GINEKOLOGIA POLSKA, 2016, 87 (08) : 581 - 584
  • [22] TRANSVAGINAL COLOR DOPPLER SONOGRAPHY OF ADNEXAL MASSES - DIFFERENCES IN BLOOD-FLOW IMPEDANCE IN BENIGN AND MALIGNANT LESIONS
    HAMPER, UM
    SHETH, S
    ABBAS, FM
    ROSENSHEIN, NB
    ARONSON, D
    KURMAN, RJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) : 1225 - 1228
  • [23] Doppler flow and arterial location in ovarian tumors
    Itakura, T
    Kikkawa, F
    Kajiyama, H
    Mitsui, T
    Kawai, M
    Mizutani, S
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2003, 83 (03) : 277 - 283
  • [24] OVARIAN-TUMORS OF LOW MALIGNANT POTENTIAL - TRANSVAGINAL DOPPLER ULTRASOUND FEATURES
    HATA, K
    HATA, T
    MANABE, A
    KITAO, M
    GYNECOLOGIC ONCOLOGY, 1992, 45 (03) : 259 - 264
  • [25] TRANSVAGINAL PULSED AND COLOR DOPPLER IMAGING FOR THE EVALUATION OF BENIGN AND MALIGNANT UTERINE-TUMORS
    HIRAI, M
    SAGAI, H
    SEKIYA, S
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1995, 49 (02) : 195 - 196
  • [26] TRANSVAGINAL COLOR DOPPLER IN THE ASSESSMENT OF PLACENTAL BLOOD-FLOW
    KURJAK, A
    PREDANIC, M
    KUPESICUREK, S
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1993, 49 (1-2): : 29 - 32
  • [27] Preoperative differentiation of malignant from benign ovarian tumors: the efficacy of morphology indexing and Doppler flow sonography
    Ueland, FR
    DePriest, PD
    Pavlik, EJ
    Kryscio, RJ
    van Nagell, JR
    GYNECOLOGIC ONCOLOGY, 2003, 91 (01) : 46 - 50
  • [28] Effects of Sedation with Medetomidine and Dexmedetomidine on Doppler Measurements of Ovarian Artery Blood Flow in Bitches
    Nicolas-Barcelo, Paloma
    Facchin, Martina
    Martinez-Taboada, Fernando
    Barrera, Rafael
    Cristobal, Jose Ignacio
    Gonzalez, Mario Alberto
    Duran-Galea, Angela
    Macias-Garcia, Beatriz
    Duque, Francisco Javier
    ANIMALS, 2021, 11 (02): : 1 - 8
  • [29] INTRAOBSERVER AND INTEROBSERVER VARIATIONS IN DETERMINING BLOOD-FLOW INDEXES WITH DOPPLER SONOGRAPHY
    KESSLER, LS
    HONEYMAN, JC
    KAUDE, JV
    LONGMATE, JA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (06) : 1326 - 1326
  • [30] TRANSVAGINAL ULTRASONOGRAPHIC CHARACTERIZATION OF OVARIAN MASSES BY MEANS OF COLOR FLOW-DIRECTED DOPPLER MEASUREMENTS AND A MORPHOLOGIC SCORING SYSTEM
    TIMORTRITSCH, IE
    LERNER, JP
    MONTEAGUDO, A
    SANTOS, R
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 168 (03) : 909 - 913