Rapid determination of sulfonamide residues in honey samples using non-targeted liquid chromatography-high resolution mass spectrometry

被引:6
|
作者
Kirkan, Ertug [1 ]
Tahir, Alaa Omar [2 ]
Bengu, Aydin Sukru [1 ]
Aslan, Hakiye [3 ]
Ciftci, Mehmet [2 ]
Aydogan, Cemil [3 ]
机构
[1] Bingol Univ, Cent Lab, Bingol, Turkey
[2] Bingol Univ, Dept Chem, Bingol, Turkey
[3] Bingol Univ, Dept Food Engn, TR-12000 Bingol, Turkey
关键词
high resolution mass spectrometry; honey; liquid chromatography; non-target screening; sulfonamides; ANTIBIOTIC-RESIDUES; FOOD; PESTICIDES; MILK;
D O I
10.1002/sscp.202000051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Honey is one of the most widespread natural harvest consumed as food and medicine. Many antibacterial groups can be used to protect bees from some bacterial diseases and infections. Among them, sulfonamides are one of the most effective antibacterial drugs used for a long time. While sulfonamides are used by beekeepers, the residues of them may appear in honey with the different levels of residues. These residues in honey at the high level of concentration can be a potential risk to the human body. In this study, a non-targeted liquid chromatography with high resolution mass spectrometry method was designed to discover known and unknown sulfonamide residues in 13 honey samples. This study includes both sample preparation with a modified Quick, Easy, Cheap, Effective, Rugged, and Safe extraction and liquid chromatography analysis. The influences of the chromatographic separation parameters such as flow rate were studied. The detection of sulfonamides was carried out by a reversed-phase chromatographic separation column (a Hypersil Gold C18, 100 mm x 2.1 mm I.D., 1.9 mu m), with gradient elution mode of mobile phase at a flow rate of 0.3 mL/min. Full MS/all-ion fragmentation was used for mass spectrometry acquisition mode. The limit of detection of sulfonamides ranged from 0.02 to 0.12 mu g/kg while the limit of quantification values was between 0.08 and 0.72 mu g/kg. The developed non-targeted analysis was successfully applied for sulfonamide residue determination in honey samples. This study also shows the analysis of the arylamine groups originated from sulfonamides that is a very relevant issue for the toxic side effect of these compounds.
引用
收藏
页码:451 / 459
页数:9
相关论文
共 50 条
  • [21] Data processing strategies for non-targeted analysis of foods using liquid chromatography/high-resolution mass spectrometry
    Fisher, Christine M.
    Croley, Timothy R.
    Knolhoff, Ann M.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 136
  • [22] Non-Targeted Detection of Synthetic Oligonucleotides in Equine Serum Using Liquid Chromatography-High-Resolution Mass Spectrometry
    Helmes, Emily
    Montgomery, Jacob
    Alarcio, Gwendolyne
    Mendoza, Herra G.
    Blea, Jeffrey A.
    Beal, Peter A.
    Moeller, Benjamin C.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (11)
  • [23] The use of gas chromatography-high resolution mass spectrometry for suspect screening and non-targeted analysis of per- and polyfluoroalkyl substances
    Casey, Jonathan S.
    Jackson, Stephen R.
    Ryan, Jeff
    Newton, Seth R.
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1693
  • [24] Determination of vancomycin in serum by liquid chromatography-high resolution full scan mass spectrometry
    Zhang, T.
    Watson, D. G.
    Azike, C.
    Tettey, J. N. A.
    Stearns, A. T.
    Binning, A. R.
    Payne, C. J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 857 (02): : 352 - 356
  • [25] Determination of cross-linking residues in a pharmaceutical polymer by liquid chromatography-high resolution full scan mass spectrometry
    Zhang, T.
    Watson, D. G.
    Lu, Duo
    Carr, D.
    Trager, L.
    TALANTA, 2008, 76 (03) : 509 - 512
  • [26] Simultaneous Determination of α-Amanitin and β-Amanitin in Mouse Plasma Using Liquid Chromatography-High Resolution Mass Spectrometry
    Bang, Young Yoon
    Lee, Min Seo
    Lim, Chang Ho
    Lee, Hye Suk
    MASS SPECTROMETRY LETTERS, 2021, 12 (03) : 112 - 117
  • [27] Determination of paraquat and diquat residues in urine samples based on solid-phase extraction and ultra performance liquid chromatography-high resolution mass spectrometry
    Pan Shengdong
    Wang Li
    Qiu Qiaoli
    He Qian
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2022, 40 (12) : 1087 - 1094
  • [28] Rapid Determination of Fumagillin Residues in Honey by Liquid Chromatography-Tandem Mass Spectrometry Using the QuEChERS Method
    Kanda, Maki
    Sasamoto, Takeo
    Takeba, Kazue
    Hayashi, Hiroshi
    Kusano, Tomoko
    Matsushima, Yoko
    Nakajima, Takayuki
    Kanai, Setsuko
    Takano, Ichiro
    JOURNAL OF AOAC INTERNATIONAL, 2011, 94 (03) : 878 - 885
  • [29] Non-targeted analysis with liquid chromatography- high resolution mass spectrometry for the identification of food packaging migrants
    Sapozhnikova, Yelena
    Nunez, Alberto
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1676
  • [30] Insights into the human metabolism of hexahydrocannabinol by non-targeted liquid chromatography-high-resolution tandem mass spectrometry
    Pitterl, Florian
    Pavlic, Marion
    Liu, Jianmei
    Oberacher, Herbert
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2024, 48 (05) : 350 - 358