Rapid determination of sulfonamide residues in honey samples using non-targeted liquid chromatography-high resolution mass spectrometry

被引:6
|
作者
Kirkan, Ertug [1 ]
Tahir, Alaa Omar [2 ]
Bengu, Aydin Sukru [1 ]
Aslan, Hakiye [3 ]
Ciftci, Mehmet [2 ]
Aydogan, Cemil [3 ]
机构
[1] Bingol Univ, Cent Lab, Bingol, Turkey
[2] Bingol Univ, Dept Chem, Bingol, Turkey
[3] Bingol Univ, Dept Food Engn, TR-12000 Bingol, Turkey
关键词
high resolution mass spectrometry; honey; liquid chromatography; non-target screening; sulfonamides; ANTIBIOTIC-RESIDUES; FOOD; PESTICIDES; MILK;
D O I
10.1002/sscp.202000051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Honey is one of the most widespread natural harvest consumed as food and medicine. Many antibacterial groups can be used to protect bees from some bacterial diseases and infections. Among them, sulfonamides are one of the most effective antibacterial drugs used for a long time. While sulfonamides are used by beekeepers, the residues of them may appear in honey with the different levels of residues. These residues in honey at the high level of concentration can be a potential risk to the human body. In this study, a non-targeted liquid chromatography with high resolution mass spectrometry method was designed to discover known and unknown sulfonamide residues in 13 honey samples. This study includes both sample preparation with a modified Quick, Easy, Cheap, Effective, Rugged, and Safe extraction and liquid chromatography analysis. The influences of the chromatographic separation parameters such as flow rate were studied. The detection of sulfonamides was carried out by a reversed-phase chromatographic separation column (a Hypersil Gold C18, 100 mm x 2.1 mm I.D., 1.9 mu m), with gradient elution mode of mobile phase at a flow rate of 0.3 mL/min. Full MS/all-ion fragmentation was used for mass spectrometry acquisition mode. The limit of detection of sulfonamides ranged from 0.02 to 0.12 mu g/kg while the limit of quantification values was between 0.08 and 0.72 mu g/kg. The developed non-targeted analysis was successfully applied for sulfonamide residue determination in honey samples. This study also shows the analysis of the arylamine groups originated from sulfonamides that is a very relevant issue for the toxic side effect of these compounds.
引用
收藏
页码:451 / 459
页数:9
相关论文
共 50 条
  • [1] A new strategy for non-targeted screening of phthalate metabolites using liquid chromatography-high resolution mass spectrometry
    Guo, Zeqin
    Feng, Yong-Lai
    Wang, Jianhua
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2019, 443 : 46 - 52
  • [2] Screening of sulfonamide antibiotics in seawater by liquid chromatography-high resolution mass spectrometry
    Yang, Shuli
    Yu, Tao
    Wu, Mingyuan
    Qin, Zhenfa
    Meng, Yuan
    Wu, Xiangqing
    Chinese Journal of Analysis Laboratory, 2021, 40 (01) : 25 - 29
  • [3] The potential for complementary targeted/non-targeted screening of novel psychoactive substances in equine urine using liquid chromatography-high resolution accurate mass spectrometry
    Cawley, Adam
    Pasin, Daniel
    Ganbat, Namuun
    Ennis, Laura
    Smart, Corrine
    Greer, Candace
    Keledjian, John
    Fu, Shanlin
    Chen, Alex
    ANALYTICAL METHODS, 2016, 8 (08) : 1789 - 1797
  • [4] Progress on Liquid Chromatography-High Resolution Mass Spectrometry in the Determination of Veterinary Drug Residues: A Review
    Zheng Y.
    Lin Q.
    Yang L.
    Zhou R.
    Shen C.
    Yi H.
    Wu J.
    Shipin Kexue/Food Science, 2023, 44 (03): : 359 - 365
  • [5] Enantiomeric determination of cathinones in environmental water samples by liquid chromatography-high resolution mass spectrometry
    Fu, Yandi
    Borrull, Francesc
    Marce, Rosa Maria
    Fontanals, Nuria
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1626
  • [6] Assessing background contamination of sample tubes used in human biomonitoring by non-targeted liquid chromatography-high resolution mass spectrometry
    Krauss, Martin
    Huber, Carolin
    Schulze, Tobias
    Bartel-Steinbach, Martina
    Weber, Till
    Kolossa-Gehring, Marike
    Lermen, Dominik
    ENVIRONMENT INTERNATIONAL, 2024, 183
  • [7] ANALYSIS OF SULFONAMIDE RESIDUES IN REAL HONEY SAMPLES USING LIQUID CHROMATOGRAPHY WITH FLUORESCENCE AND TANDEM MASS SPECTROMETRY DETECTION
    Toelgyesi, Adam
    Berky, Robert
    Bekesi, Katalin
    Fekete, Szabolcs
    Fekete, Jeno
    Sharma, Virender K.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (08) : 1105 - 1125
  • [8] Determination of three coriaria lactones in honey by ultra high performance liquid chromatography-high resolution mass spectrometry
    Yin Yao
    Chen Huilan
    Chen Lei
    Bie Xiaomei
    Ding Tao
    Zhang Xiaoyan
    Wu Bin
    Shen Chongyu
    Zhang Rui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (07) : 711 - 714
  • [9] Rapid Determination of Nitroimidazole Residues in Honey by Liquid Chromatography/Tandem Mass Spectrometry
    Kanda, Maki
    Sasamoto, Takeo
    Takeba, Kazue
    Hayashi, Hiroshi
    Kusano, Tomoko
    Matsushima, Yoko
    Nakajima, Takayuki
    Kanai, Setsuko
    Takano, Ichiro
    JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (03) : 923 - 931
  • [10] Profiling organic pollutants in environmental water by dansylation-based non-targeted liquid chromatography-high resolution mass spectrometry analysis
    Chen, Bin
    An, Lirong
    Li, Feng
    Tang, Yanan
    CANADIAN JOURNAL OF CHEMISTRY, 2024, 102 (09) : 581 - 588