Characterisation of air-void systems in concrete

被引:13
|
作者
Liu, Zhichao [1 ]
Hansen, Will [1 ]
Meng, Bo [1 ]
机构
[1] Univ Michigan, Dept Civil & Environm Engn, Ann Arbor, MI 48109 USA
关键词
STABILITY;
D O I
10.1680/macr.15.00074
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The air-void system in both fresh and hardened states for different concrete mixes was measured and characterised using the methods presented in ASTM C231 and ASTM C457 respectively. The mix variables included two water/binder (w/b) ratios (0.33 and 0.45), one replacement level of Portland cement with slag cement (50%) and a range of air contents achieved through the use of different air-entraining agents. Consistent results were obtained on duplicate specimens using the two testing procedures. The cumulative size distribution of the air voids estimated from chord length measurement was satisfactorily represented by an S-shaped function from which the differential distribution can be derived. The importance of air-void fineness on the spacing was clearly illustrated by the small variation in Powers' spacing factor when large air bubbles were included.
引用
收藏
页码:178 / 186
页数:9
相关论文
共 50 条
  • [41] Impact of Hydrated Cement Paste Content and Entrained Air-Void System Parameters on the Durability of Concrete
    Peterson, Karl
    Sutter, Lawrence
    NORDIC CONCRETE RESEARCH, 2011, 43 (01): : 251 - 254
  • [42] HIGH AIR-VOID VOLUME IMPLICATIONS FOR ASPHALT CONCRETE SERVICE-LIFE AND PRICE PENALTY
    Salini, Reus
    Lenngren, Carl Anders
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2022, 31 (01):
  • [43] Determining optimum air-void spacing requirement for a given concrete mixture design using poromechanics
    Rahman, Syeda
    Grasley, Zachary
    INTERNATIONAL JOURNAL OF PAVEMENT ENGINEERING, 2018, 19 (07) : 601 - 610
  • [44] COMPARATIVE-STUDY OF THE AIR-VOID STABILITY IN A NORMAL AND A CONDENSED SILICA FUME FIELD CONCRETE
    PIGEON, M
    AITCIN, PC
    LAPLANTE, P
    ACI MATERIALS JOURNAL, 1987, 84 (03) : 194 - 199
  • [45] Some findings on the usefulness of image analysis for determining the characteristics of the air-void system on hardened concrete
    Pleau, R
    Pigeon, M
    Laurencot, JL
    CEMENT & CONCRETE COMPOSITES, 2001, 23 (2-3): : 237 - 246
  • [46] Impact of concrete placing method on air content, air-void system parameters, and freeze-thaw durability
    Hover, Kenneth C.
    Phares, Roger J.
    Transportation Research Record, 1996, (1532) : 1 - 8
  • [47] Experimental Investigation on the Influence of Water-cement Ratio on Air-void Parameters of Cement Concrete
    Zhang, JinXi
    Wang, Chao
    Guo, MingYang
    Ma, MaoCheng
    MATERIALS IN INDUSTRY AND NANOTECHNOLOGY, 2013, 771 : 29 - +
  • [48] Effect of w/c ratio on air-void system of foamed concrete and their influence on mechanical properties
    Wee, Tiong-Huan
    Daneti, Saradhi Babu
    Tamilselvan, Thangayah
    MAGAZINE OF CONCRETE RESEARCH, 2011, 63 (08) : 583 - 595
  • [49] THE USE OF THE TAS FOR DETERMINATION OF AIR-VOID SYSTEM AND CEMENT-PASTE CONTENT IN HARDENED CONCRETE
    GUDMUNDSSON, H
    CHATTERJI, S
    MICROSCOPICA ACTA, 1980, : 163 - 170
  • [50] Fractal Analysis of Air-void Structure of Hybrid Basalt-Polypropylene Fibre Reinforced Concrete
    Niu, Ditao
    Luo, Yang
    Su, Li
    Huang, Daguan
    Cailiao Daobao/Materials Reports, 2022, 36 (13):