Optimisation of coronary angiographic views: Qualitative and quantitative evaluation of a new system

被引:0
|
作者
Finet, G
Lienard, J
Masquet, C
Eifferman, A
Funck, F
Lefevre, T
Marco, J
Amiel, M
Beaune, J
机构
[1] GE MED SYST,F-78533 BUC,FRANCE
[2] HOP LARIBOISIERE,SERV CARDIOL,F-75475 PARIS 10,FRANCE
[3] CTR HOSP RENE DUBOS,SERV CARDIOL,F-95301 PONTOISE,FRANCE
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A coronary angiographic view is said to be ''optimal'' when the directing radius of the X-ray beam is perpendicular to the long axis of a stenosis. The object was to fulfill two criteria : 1) the accurate calculation of the spatial orientation of the stenosis to obtain the optimal position, 2) rapid and optimal positioning of the angiographic material with easy rotation around the axis of the stenosis. Two combined solutions were proposed : the Advantx L/C (GE Medical systems) angiocardiographic system with three motorised axes of rotation and a specific software. This software takes into account two longitudinal axes of the stenosis traced by the operator in two conventional incidences and then determines the angles of optimal positioning (accuracy +/- 5 degrees). During 97 consecutive coronary angiogrammes, the software was used in 23 cases (24 %) and judged to be useful in 16 cases (70 %). In 2 of the 23 cases (8 %) the mechanical angles calculated could not be used, the incidences being incompatible with the patient's position. During the angiogrammes, the best two images of stenosis (one conventional, one optimal) were retained to form a pair of images. Eight observers analysed 37 pairs of images shown side by side. 65 % of the images selected from each pair as being the best descriptive appearance of the stenosis came from the optimised system. During quantitative analysis, only the length of stenosis differed statistically between the two modes of acquisition (1.26 +/- 0.36 mm; p = 0.0014). This system is useful during coronary angiography for providing optimal views of stenosis free from any geometric distorsion and without superimposition of adjacent branches.
引用
收藏
页码:1617 / 1625
页数:9
相关论文
共 50 条
  • [31] Acute coronary syndrome: a critical qualitative and quantitative analysis of current evaluation methods
    Schoeffel, Norman
    Vitzthum, Karin
    Groneberg, David A.
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2010, 11 (10) : 780 - 783
  • [32] Quantitative and qualitative research Received and interpretivist views of science
    Dharamsi, Shafik
    Scott, Ian
    CANADIAN FAMILY PHYSICIAN, 2009, 55 (08) : 843 - 844
  • [33] A new quantitative analysis system for the evaluation of coronary bifurcation lesions: Comparison with current conventional methods
    Goktekin, Omer
    Kaplan, Sahin
    Dimopoulos, Konstantinos
    Barlis, Peter
    Tanigawa, Jun
    Vatankulu, Mehmet Akif
    Koning, Gerhard
    Tuinenburg, Joan C.
    Di Mario, Carlo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (02) : 172 - 180
  • [34] QUANTITATIVE CORONARY ANGIOGRAPHIC ANALYSIS (QCAA) - COMPARISON OF 3 TYPES OF CORONARY STENTS
    EECKHOUT, E
    GOY, JJ
    STAUFFER, JC
    VOGT, P
    KAPPENBERGER, L
    CIRCULATION, 1993, 88 (04) : 641 - 641
  • [35] COMPARATIVE QUANTITATIVE ANGIOGRAPHIC ANALYSIS OF DIRECTIONAL CORONARY ATHERECTOMY AND BALLOON CORONARY ANGIOPLASTY
    UMANS, VAWM
    BEATT, KJ
    RENSING, BJWM
    HERMANS, WRM
    DEFEYTER, PJ
    SERRUYS, PW
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (17): : 1556 - 1563
  • [36] Impact of frame selection on quantitative coronary angiographic analysis after coronary stenting
    Fischell, TA
    Maheshwari, A
    Mirza, RA
    Haller, S
    Carter, AJ
    Popma, JJ
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 64 (04) : 460 - 467
  • [37] Angiographic Evaluation of Epicardial and Microvascular Coronary Flow
    Rind, Efrat
    Arbel, Yaron
    Finkelstein, Ariel
    Keren, Gad
    Banai, Shmuel
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2009, 11 (03): : 173 - 177
  • [38] Angiographic evaluation of the dominance patterns of coronary circulation
    Hasanovic, Aida
    Ascic-Buturovic, Belma
    HEALTHMED, 2012, 6 (06): : 2229 - 2233
  • [39] Standardized angiographic projections allow evaluation of coronary artery side branches with quantitative flow ratio (QFR)
    Antoniadis, M.
    Blum, M.
    Ussat, M.
    Laufs, U.
    Lenk, K.
    IJC HEART & VASCULATURE, 2024, 50
  • [40] APPROPRIATE USES OF ANGIOGRAPHIC FOLLOW-UP IN THE EVALUATION OF NEW TECHNOLOGIES FOR CORONARY INTERVENTION
    BAIM, DS
    KUNTZ, RE
    CIRCULATION, 1994, 90 (05) : 2560 - 2563