Optimisation of coronary angiographic views: Qualitative and quantitative evaluation of a new system

被引:0
|
作者
Finet, G
Lienard, J
Masquet, C
Eifferman, A
Funck, F
Lefevre, T
Marco, J
Amiel, M
Beaune, J
机构
[1] GE MED SYST,F-78533 BUC,FRANCE
[2] HOP LARIBOISIERE,SERV CARDIOL,F-75475 PARIS 10,FRANCE
[3] CTR HOSP RENE DUBOS,SERV CARDIOL,F-95301 PONTOISE,FRANCE
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A coronary angiographic view is said to be ''optimal'' when the directing radius of the X-ray beam is perpendicular to the long axis of a stenosis. The object was to fulfill two criteria : 1) the accurate calculation of the spatial orientation of the stenosis to obtain the optimal position, 2) rapid and optimal positioning of the angiographic material with easy rotation around the axis of the stenosis. Two combined solutions were proposed : the Advantx L/C (GE Medical systems) angiocardiographic system with three motorised axes of rotation and a specific software. This software takes into account two longitudinal axes of the stenosis traced by the operator in two conventional incidences and then determines the angles of optimal positioning (accuracy +/- 5 degrees). During 97 consecutive coronary angiogrammes, the software was used in 23 cases (24 %) and judged to be useful in 16 cases (70 %). In 2 of the 23 cases (8 %) the mechanical angles calculated could not be used, the incidences being incompatible with the patient's position. During the angiogrammes, the best two images of stenosis (one conventional, one optimal) were retained to form a pair of images. Eight observers analysed 37 pairs of images shown side by side. 65 % of the images selected from each pair as being the best descriptive appearance of the stenosis came from the optimised system. During quantitative analysis, only the length of stenosis differed statistically between the two modes of acquisition (1.26 +/- 0.36 mm; p = 0.0014). This system is useful during coronary angiography for providing optimal views of stenosis free from any geometric distorsion and without superimposition of adjacent branches.
引用
收藏
页码:1617 / 1625
页数:9
相关论文
共 50 条
  • [1] Can we optimize our angiographic views every time? Qualitative and quantitative evaluation of a new functionality
    Finet, G
    Masquet, C
    Eifferman, A
    Funck, F
    Lefevre, T
    Marco, J
    Amiel, M
    Beaune, J
    Lienard, J
    INVESTIGATIVE RADIOLOGY, 1996, 31 (08) : 523 - 531
  • [2] QUANTITATIVE ANGIOGRAPHIC EVALUATION OF THE RESULTS OF CORONARY ANGIOPLASTY
    GIORGI, LV
    GREENBERG, JD
    LIGON, RW
    HARTZLER, GO
    MCCALLISTER, BD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (02) : 520 - 520
  • [3] QUANTITATIVE AND QUALITATIVE CORONARY ANGIOGRAPHIC ANALYSIS - REVIEW OF METHODS, UTILITY, AND LIMITATIONS
    HERMILLER, JB
    CUSMA, JT
    SPERO, LA
    FORTIN, DF
    HARDING, MB
    BASHORE, TM
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 25 (02): : 110 - 131
  • [4] Validation of a new UNIX-based quantitative coronary angiographic system for the measurement of coronary artery lesions
    Bell, MR
    Britson, PJ
    Chu, A
    Holmes, DR
    Bresnahan, JF
    Schwartz, RS
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1997, 40 (01): : 66 - 74
  • [5] A MICROCOMPUTER BASED AUTOMATED, QUANTITATIVE CORONARY ANGIOGRAPHIC ANALYSIS SYSTEM
    SANTAMORE, WP
    KAHL, FR
    KUTCHER, MA
    NEGIN, M
    WHITEMAN, JL
    KASE, JP
    LITTLE, WC
    ANNALS OF BIOMEDICAL ENGINEERING, 1988, 16 (04) : 367 - 377
  • [6] Best angiographic views to minimize coronary artery foreshortening
    Dodge, T
    Sparano, AM
    Ryan, K
    McLean, C
    Moyhihan, J
    Ralston, A
    AlMousa, E
    Daley, WL
    CIRCULATION, 1997, 96 (08) : 427 - 427
  • [7] COMPARISON BY QUANTITATIVE ANGIOGRAPHIC ASSESSMENT OF CORONARY STENOSES OF ONE VIEW SHOWING THE SEVEREST NARROWING TO 2 ORTHOGONAL VIEWS
    LESPERANCE, J
    HUDON, G
    WHITE, CW
    LAURIER, J
    WATERS, D
    AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (08): : 462 - 465
  • [8] A digital viewer with quantitative coronary angiographic information
    Yfantis, EA
    Popovich, A
    Pinkerton, CA
    Than, G
    1998 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS, VOLS 1-5, 1998, : 881 - 884
  • [9] PROGNOSTIC VALUE OF SOME QUALITATIVE AND QUANTITATIVE CORONARY ANGIOGRAPHIC PARAMETERS IN PATIENTS WITH UNSTABLE ANGINA-PECTORIS
    SAVCHENKO, AP
    SMIRNOV, AA
    SHIBLEVA, VV
    ISHANOV, AA
    KARPOV, YA
    KARDIOLOGIYA, 1992, 32 (01) : 25 - 28
  • [10] CLINICAL AND ANGIOGRAPHIC OUTCOME AFTER DIRECTIONAL CORONARY ATHERECTOMY - A QUALITATIVE AND QUANTITATIVE-ANALYSIS USING CORONARY ARTERIOGRAPHY AND INTRAVASCULAR ULTRASOUND
    POPMA, JJ
    MINTZ, GS
    SATLER, LF
    PICHARD, AD
    KENT, KM
    CHUANG, YC
    MATAR, F
    BUCHER, TA
    MERRITT, AJ
    LEON, MB
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (13): : E55 - E64