Hyperspectral Imaging: Comparison of Acousto-Optic and Liquid Crystal Tunable Filters

被引:16
|
作者
Abdlaty, Ramy [1 ]
Sahli, Samir [2 ]
Hayward, Joseph [3 ]
Fang, Qiyin [1 ,2 ]
机构
[1] Egyptian Armed Forces, Cairo, Egypt
[2] McMaster Univ, Engn Phys, Hamilton, ON, Canada
[3] Hamilton Hlth Sci, Juravinski Canc Ctr, Hamilton, ON, Canada
关键词
Hyperspectral Imaging; Tunable Filters; AOTF; LCTF; FOOD QUALITY; CLASSIFICATION; FUNDAMENTALS;
D O I
10.1117/12.2282532
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work, we report a performance comparison of an acousto-optic tunable filter (AOTF), and a liquid crystal tunable filter (LCTF) based on a novel dual-arm hyperspectral imaging (HSI) configuration. The main purpose of this work is to highlight the leverage points of each tunable filter, in order to facilitate filter choice in HSI design. Three main parameters are experimentally examined: spectral resolution, out-of-band suppression, and image quality in the sense of spatial resolution. The experimental results, using wideband illumination, laser lines, and a spatial test target (USAF-1951) emphasized the superiority of AOTF in spectral resolution, out-of-band suppression and random switching speed between wavelengths. The same experiments demonstrated LCTF to have better performance in terms of the spatial image resolution, both horizontal and vertical, and high definition quality. In conclusion, the efficient design of an HSI system is application-dependent. For medical applications, for instance, if the tissue of interest has undefined optical properties, or contains close spectral features, AOTF might be the better option. Otherwise, LCTF is more convenient and simpler to use, especially if the tissue chromophore's spatial mapping is needed.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] 400-1000nm imaging spectrometer based on acousto-optic tunable filters
    Calpe-Maravilla, J
    Vila-Frances, J
    Ribes-Gomez, E
    Duran-Bosch, V
    Munoz-Mari, J
    Amoros-Lopez, J
    Gomez-Chova, L
    Tajahuerce-Romera, E
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES VIII, 2004, 5570 : 460 - 471
  • [42] Bandpass response of collinear beam acousto-optic tunable filters
    Chang, IC
    Xu, J
    Wo, D
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 745 - 748
  • [43] Light image projection using acousto-optic tunable filters
    Gurevich, BS
    Akkoziev, IA
    Alymkulov, SA
    Andreyev, SV
    Kaupinen, MV
    3RD INTERNATIONAL CONFERENCE ON OPTICAL INFORMATION PROCESSING, 1999, 3900 : 118 - 124
  • [44] Principles and analytical applications of acousto-optic tunable filters, an overview
    Tran, CD
    TALANTA, 1997, 45 (02) : 237 - 248
  • [45] Limitation and improvement of collinear beam acousto-optic tunable filters
    Chang, I. C.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 821 - 824
  • [46] Acousto-optic tunable filters for high resolution light microscopy
    Wachman, ES
    Niu, W
    Shonat, RD
    Koretscky, AP
    Farkas, DL
    BIOPHYSICAL JOURNAL, 1997, 72 (02) : MPME9 - MPME9
  • [47] HYPER SPECTROMETER BASED ON AN ACOUSTO-OPTIC TUNABLE FILTERS FOR UAVS
    Pozhar, Vitold E.
    Machikhin, Alexander S.
    Gaponov, Maxim, I
    Shirokov, Sergei, V
    Mazur, Mikhail M.
    Sheryshev, Alexei E.
    LIGHT & ENGINEERING, 2019, 27 (03): : 99 - 104
  • [48] Angular and power characteristics of noncollinear acousto-optic tunable filters
    Georgiev, G
    Georgieva, E
    Konstantinov, L
    OPTICS AND LASERS IN ENGINEERING, 1999, 31 (01) : 1 - 12
  • [49] Acousto-optic tunable filters in two-mode fibers
    Ostling, D
    Engan, HE
    OPTICAL FIBER TECHNOLOGY, 1997, 3 (02) : 177 - 183
  • [50] Tunable acousto-optic filters with the multiple interaction of light and sound
    Voloshinov, VB
    Magdich, LN
    Knyazev, GA
    QUANTUM ELECTRONICS, 2005, 35 (11) : 1057 - 1063