Light-gauge steel-frame - wood structural panel shear wall design method

被引:26
|
作者
Branston, A. E. [1 ]
Boudreault, F. A. [1 ]
Chen, C. Y. [1 ]
Rogers, C. A. [1 ]
机构
[1] McGill Univ, Dept Civil Engn & Appl Mech, Montreal, PQ H3A 2K6, Canada
关键词
shear wall; light-gauge steel; wood structural panel; earthquake; wind; design;
D O I
10.1139/L06-036
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Design guidelines for laterally loaded (wind and seismic) light-gauge steel-frame - wood structural panel shear walls are currently unavailable in Canadian standards and codes. A research project was initiated at McGill University in 2001 with the objective of developing a shear wall design method that could be used in conjunction with the 2005 National Building Code of Canada (NBCC). An extensive program of tests was first carried out to establish a database of shear wall information. The equivalent energy elastic-plastic (EEEP) analysis approach was then chosen to derive key design parameters for the shear walls, including nominal shear strength, elastic stiffness, overstrength, and ductility. This paper presents the development of the proposed design method, the resulting nominal strength and unit elastic stiffness values according to typical perimeter fastener schedules and sheathing type, and the calibration of a resistance factor to the 2005 NBCC wind loads. Overstrength values used for a capacity-based seismic design approach and factors of safety for wind loading are also provided.
引用
收藏
页码:872 / 889
页数:18
相关论文
共 50 条
  • [21] Shear capacity of cold-formed light-gauge steel framed shear-wall panels with fiber cement board sheathing
    Wasim Khaliq
    Ahmed Moghis
    International Journal of Steel Structures, 2017, 17 : 1404 - 1414
  • [22] Comparing hysteretic behavior of light-gauge, steel plate shear walls and braced frames
    Berman, JW
    Celik, OC
    Bruneau, M
    ENGINEERING STRUCTURES, 2005, 27 (03) : 475 - 485
  • [23] Performance of Wood-Frame Wall with Thin ECC Shear Panel
    Lewis, Michael C.
    Gupta, Rakesh
    Miller, Thomas H.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2009, 14 (03) : 123 - 129
  • [24] Estimating wood structural panel diaphragm and shear wall deflection
    Skaggs, Thomas D.
    Martin, Zeno A.
    Practice Periodical on Structural Design and Construction, 2004, 9 (03) : 136 - 141
  • [25] Experimental study on shear performance of CCA-sheathed light-gauge steel framing walls
    Li, Yuanqi
    Hong, Chi
    Qin, Yafei
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (09): : 151 - 157
  • [26] DEVELOPMENT OF BIM-BASED QUANTITY TAKEOFF FOR LIGHT-GAUGE STEEL WALL FRAMING SYSTEMS
    Khosakitchalert, Chavanont
    Yabuki, Nobuyoshi
    Fukuda, Tomohiro
    JOURNAL OF INFORMATION TECHNOLOGY IN CONSTRUCTION, 2020, 25 : 522 - 544
  • [27] A New Algorithm for Optimal Parameter Settings of Light-Gauge Steel Wall Sound Isolation Systems
    Lee, Chao-Tsung
    Kuo, Hsin-Chuan
    Liou, Der-Yuan
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 199 - 209
  • [28] COMPUTER-AIDED-DESIGN FOR COLD ROLL FORMING OF LIGHT-GAUGE STEEL MEMBERS
    ONA, H
    JIMMA, T
    KOZONO, H
    NAKAKO, T
    JSME INTERNATIONAL JOURNAL SERIES I-SOLID MECHANICS STRENGTH OF MATERIALS, 1990, 33 (02): : 220 - 226
  • [29] INVESTIGATION ON TEMPERATURE DISTRIBUTION OF LIGHT GAUGE STEEL FRAME (LSF) WALL
    Song, Qianyi
    Wu, Xiaobin
    Han, Lin-Hai
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1447 - 1458
  • [30] A robotic method for installing batt thermal insulation into prefabricated light-frame wood wall panel
    Xiao Han
    Cheng-Hsuan Yang
    Yuxiang Chen
    Construction Robotics, 2025, 9 (1)