Computer aided distal locking guidance of intramedullary nail by X-ray image analysis

被引:0
|
作者
Covavisaruch, N [1 ]
Simmami, K [1 ]
Vatanawood, W [1 ]
Ratanachai, W [1 ]
机构
[1] Chulalongkorn Univ, Dept Comp Engn, Bangkok 10330, Thailand
关键词
intramedullary nail; distal locking; x-ray image; image analysis; computer aided;
D O I
10.1117/12.534869
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Distal locking of intramedullary nail inside a patient's broken bone is a difficult step in an orthopaedic surgery. It is hard not only because surgeons must locate the direction and align two distal holes in a 3D space by using 2D x-ray images, but also because the intramedullary nail can twist in unknown 3D direction and position during an operation. This process normally takes a long time, heavily uses x-ray radiation and hence exposes surgeons and patients to high doses of x-ray radiation. Longer surgical duration also increases the risk of high blood loss and prolonged anesthesia towards the patient. This research proposes a methodology to help reduce the usage of x-ray radiation, and to also simplify the distal locking process, through the utilization of simple devices along with x-ray image analysis.
引用
收藏
页码:411 / 420
页数:10
相关论文
共 50 条
  • [1] AN IMAGE INTENSIFIER LASER GUIDANCE-SYSTEM FOR THE DISTAL LOCKING OF AN INTRAMEDULLARY NAIL
    GOODALL, JD
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1991, 22 (04): : 339 - 339
  • [2] Precise 3D pose recovery from single calibrated X-ray image for computer-assisted distal locking of intramedullary nails
    Zheng, Guoyan
    Zhang, Xuan
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S250 - S252
  • [3] Nail over nail technique for distal locking of femoral intramedullary nails
    Rohilla, Rajesh
    Singh, Roop
    Magu, Narender
    Devgun, Ashish
    Siwach, Ramchander
    Gulia, Ashish
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 1107 - 1112
  • [4] Nail over nail technique for distal locking of femoral intramedullary nails
    Rajesh Rohilla
    Roop Singh
    Narender Magu
    Ashish Devgun
    Ramchander Siwach
    Ashish Gulia
    International Orthopaedics, 2009, 33
  • [5] COMPUTER AIDED X-RAY DIAGNOSIS
    LODWICK, GS
    REICHERT.
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1968, : 9 - &
  • [6] FUNDAMENTALS OF COMPUTER-AIDED X-RAY ANALYSIS OF SPINE
    SUH, CH
    JOURNAL OF BIOMECHANICS, 1974, 7 (02) : 161 - 169
  • [7] Chest X-Ray Analysis for Computer-Aided Diagnostic
    Le, Kim
    ADVANCED COMPUTING, PT III, 2011, 133 : 300 - 309
  • [8] Placement of the distal locking screws of the femoral intramedullary nail without radiation
    Steriopoulos, KA
    Kontakis, GM
    Katonis, PG
    Galanakis, IA
    Dretakis, EK
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1996, 115 (01) : 43 - 44
  • [9] Fatigue strength of common tibial intramedullary nail distal locking screws
    Griffin L.V.
    Harris R.M.
    Zubak J.J.
    Journal of Orthopaedic Surgery and Research, 4 (1)
  • [10] Endoscopy-assisted distal locking of an intramedullary nail: A new experimental technique to reduce radiation exposure during distal locking of the intramedullary nails
    Davut, Serkan
    Dogramaci, Yunus
    JOINT DISEASES AND RELATED SURGERY, 2021, 32 (03): : 642 - 648