His-Bundle Pacing for Identifying Optimal Ablation Sites in Patients Undergoing Atrioventricular Junction Ablation

被引:1
|
作者
Kulkarni, Nitin [1 ]
Moore, Curtiss [1 ]
Pandey, Ambarish [1 ]
Castillo, Demetrio [1 ]
Ayers, Colby [1 ,2 ]
Joglar, Jose [1 ]
Wu, Richard [1 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Internal Med, Div Cardiol, Dallas, TX 75390 USA
[2] Univ Texas Southwestern Med Ctr Dallas, Dept Clin Sci, Dallas, TX 75390 USA
来源
关键词
atrial fibrillation; AVJ junction ablation; AVN node ablation; his-bundle pacing; CARDIAC RESYNCHRONIZATION; ATRIAL;
D O I
10.1111/pace.13019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atrioventricular (AV) junction (AVJ) ablation is conventionally performed by localizing the His-bundle electrogram (HBE). Identification of HBE in the presence of atrial fibrillation (AF) can be difficult, and can make this simple procedure challenging. In this study, we describe our experience with an alternative approach to localize optimal ablation sites using His-bundle pacing (HBP). Methods: Between 1/1/2014 and 12/31/2015, we performed 13 AVJ ablations using the standard electrogram-guided approach and 11 ablations using HBP. All cases utilized a long femoral guiding sheath and an 8-mm-tip electrode radiofrequency (RF) energy ablation catheter. Pacing was performed at high output (10 mA at 2 ms) to initially achieve right bundle branch capture. The catheter was withdrawn until a narrow QRS morphology and increased stim-to-QRS time were observed. HBP was confirmed when paced and native QRS were identical in morphology. RF energy was applied at the site of HBP capture until AV block was observed. Results: Baseline characteristics of patients in each arm were not significantly different. Compared with the standard approach, HBP was associated with trends toward lower RF applications (3 vs. 2, P = 0.16) and shorter mean RF time (208 seconds vs. 128 seconds, P = 0.19). Conclusion: HBP is an effective technique to identify optimal ablation sites during AVJ ablation and may shorten procedure time. HBP can be used to identify the AV node during AF without recording the His potential. Future studies with larger sample size are needed to better characterize the utility of this technique. (PACE 2017; 40: 242-246)
引用
收藏
页码:242 / 246
页数:5
相关论文
共 50 条
  • [31] SEGMENTAL VENTRICULAR DYSFUNCTION FOLLOWING HIS-BUNDLE ABLATION
    WARREN, R
    VOHRA, J
    CHAN, W
    ANDREWS, J
    LICHTENSTEIN, M
    HUNT, D
    BINNS, D
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1988, 18 (03): : 358 - 358
  • [32] CARDIOLOGICAL HIGHLIGHTS .9. HIS-BUNDLE ABLATION
    不详
    MUNCHENER MEDIZINISCHE WOCHENSCHRIFT, 1984, 126 (13): : A118 - A118
  • [33] HIS-BUNDLE ABLATION - SURGICAL AND NON-SURGICAL
    JOHNS, J
    HARPER, R
    SHARDEY, G
    ROSENFELDT, F
    MIDDLEBROOK, K
    ANDERSON, S
    PITT, A
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1983, 13 (04): : 405 - 405
  • [34] HIS-BUNDLE ABLATION FOR MEDICALLY REFRACTORY ATRIAL TACHYARRHYTHMIAS
    SMITH, WM
    HOOD, MA
    MCALISTER, HF
    ASHTON, N
    BARBER, A
    ROBINSON, MC
    NEW ZEALAND MEDICAL JOURNAL, 1989, 102 (876) : 513 - 513
  • [35] AN IMPROVED TECHNIQUE FOR HIS-BUNDLE RECORDING AND ABLATION IN DOGS
    WITKOWSKI, FX
    PENKOSKE, PA
    JOURNAL OF SURGICAL RESEARCH, 1990, 49 (04) : 337 - 340
  • [36] Peri-left bundle branch pacing after atrioventricular node ablation and failed his bundle pacing in atrial fibrillation
    Tondas, Alexander Edo
    Pranata, Raymond
    Han Hongwei
    JOURNAL OF ARRHYTHMIA, 2020, 36 (01) : 203 - 205
  • [37] Left Bundle Branch Pacing Postatrioventricular Junction Ablation for Atrial Fibrillation: Propensity Score Matching With His Bundle Pacing
    Cai, Mengxing
    Wu, Shengjie
    Wang, Songjie
    Zheng, Rujie
    Jiang, Limeng
    Lian, Liyou
    He, Yanlei
    Zhu, Ling
    Xu, Lei
    Ellenbogen, Kenneth A.
    Whinnett, Zachary, I
    Su, Lan
    Huang, Weijian
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2022, 15 (10): : 656 - 667
  • [38] Biventricular versus His bundle pacing after atrioventricular node ablation in heart failure patients with narrow QRS
    Zizek, David
    Antolic, Bor
    Meznar, Anja Zupan
    Zavrl-Dzananovic, Dinko
    Jan, Matevz
    Stublar, Jernej
    Pernat, Andrej
    ACTA CARDIOLOGICA, 2022, 77 (03) : 222 - 230
  • [39] Long-term performance and risk factors analysis after permanent His-bundle pacing and atrioventricular node ablation in patients with atrial fibrillation and heart failure
    Su, Lan
    Cai, Mengxing
    Wu, Shengjie
    Wang, Songjie
    Xu, Tiancheng
    Vijayaraman, Pugazhendhi
    Huang, Weijian
    EUROPACE, 2020, 22 : 19 - 26
  • [40] EFFECT OF HIS-BUNDLE ABLATION AND RATE RESPONSIVE PACING ON EXERCISE CAPACITY AND QUALITY OF LIFE IN PATIENTS WITH ATRIAL-FIBRILLATION
    KAY, GN
    BUBIEN, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04): : 500 - 500