His-Bundle Pacing for Identifying Optimal Ablation Sites in Patients Undergoing Atrioventricular Junction Ablation

被引:1
|
作者
Kulkarni, Nitin [1 ]
Moore, Curtiss [1 ]
Pandey, Ambarish [1 ]
Castillo, Demetrio [1 ]
Ayers, Colby [1 ,2 ]
Joglar, Jose [1 ]
Wu, Richard [1 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Internal Med, Div Cardiol, Dallas, TX 75390 USA
[2] Univ Texas Southwestern Med Ctr Dallas, Dept Clin Sci, Dallas, TX 75390 USA
来源
关键词
atrial fibrillation; AVJ junction ablation; AVN node ablation; his-bundle pacing; CARDIAC RESYNCHRONIZATION; ATRIAL;
D O I
10.1111/pace.13019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atrioventricular (AV) junction (AVJ) ablation is conventionally performed by localizing the His-bundle electrogram (HBE). Identification of HBE in the presence of atrial fibrillation (AF) can be difficult, and can make this simple procedure challenging. In this study, we describe our experience with an alternative approach to localize optimal ablation sites using His-bundle pacing (HBP). Methods: Between 1/1/2014 and 12/31/2015, we performed 13 AVJ ablations using the standard electrogram-guided approach and 11 ablations using HBP. All cases utilized a long femoral guiding sheath and an 8-mm-tip electrode radiofrequency (RF) energy ablation catheter. Pacing was performed at high output (10 mA at 2 ms) to initially achieve right bundle branch capture. The catheter was withdrawn until a narrow QRS morphology and increased stim-to-QRS time were observed. HBP was confirmed when paced and native QRS were identical in morphology. RF energy was applied at the site of HBP capture until AV block was observed. Results: Baseline characteristics of patients in each arm were not significantly different. Compared with the standard approach, HBP was associated with trends toward lower RF applications (3 vs. 2, P = 0.16) and shorter mean RF time (208 seconds vs. 128 seconds, P = 0.19). Conclusion: HBP is an effective technique to identify optimal ablation sites during AVJ ablation and may shorten procedure time. HBP can be used to identify the AV node during AF without recording the His potential. Future studies with larger sample size are needed to better characterize the utility of this technique. (PACE 2017; 40: 242-246)
引用
收藏
页码:242 / 246
页数:5
相关论文
共 50 条
  • [1] Cryoablation vs. radiofrequency ablation of the atrioventricular node in patients with His-bundle pacing
    Zweerink, Alwin
    Bakelants, Elise
    Stettler, Carine
    Burri, Haran
    EUROPACE, 2021, 23 (03): : 421 - 430
  • [2] Atrioventricular junction ablation in patients with conduction system pacing leads: A comparison of His-bundle vs left bundle branch area pacing leads
    Pillai, Ajay
    Kolominsky, Jeffrey
    Koneru, Jayanthi N.
    Kron, Jordana
    Shepard, Richard K.
    Kalahasty, Gautham
    Huang, Weijian
    Verma, Atul
    Ellenbogen, Kenneth A.
    HEART RHYTHM, 2022, 19 (07) : 1116 - 1123
  • [3] His-Bundle Pacing Post-Atrioventricular Node Ablation Mapping His-Bundle Potential From "Down Under"
    Linz, Dominik
    Pitman, Bradley
    Kadhim, Kadhim
    O'Shea, Catherine
    Mahajan, Rajiv
    Sanders, Prashanthan
    Lau, Dennis H.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (02) : 258 - 259
  • [4] Atrioventricular node ablation and His bundle pacing
    Vijayaraman, Pugazhendhi
    Subzposh, Faiz A.
    Naperkowski, Angela
    EUROPACE, 2017, 19 : 10 - 16
  • [5] Feasibility of His bundle pacing and atrioventricular junction ablation with left bundle branch area pacing as backup
    Mahajan, Ankit
    Trivedi, Rohan
    Subzposh, Faiz A.
    Vijayaraman, Pugazhendhi
    HEART RHYTHM, 2024, 21 (07) : 1180 - 1181
  • [6] Atrioventricular nodal ablation and his-bundle pacing: An acute canine model for proarrhythmic risk assessment
    Olivier, NB
    Eyster, GE
    Sanders, R
    Cheng, J
    Bohart, G
    Girand, M
    Bailie, M
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (12) : 1356 - 1360
  • [7] His bundle pacing versus left bundle branch area pacing in patients undergoing atrioventricular node ablation: A prospective and comparative study
    Chaumont, Corentin
    Azincot, Maxime
    Savoure, Arnaud
    Al Hamoud, Raphael
    Popescu, Elena
    Auquier, Nathanael
    Viart, Guillaume
    Mirolo, Adrian
    Eltchanioff, Helena
    Anselme, Frederic
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2024, 117 (8-9) : 505 - 513
  • [8] An alternative to His bundle pacing after atrioventricular junctional ablation
    Chen, Peng-Sheng
    HEART RHYTHM, 2007, 4 (07) : 988 - 988
  • [9] COMPARISON OF CRYOABLATION OF THE ATRIOVENTRICULAR NODE VERSUS CATHETER ABLATION OF THE HIS-BUNDLE
    GERMAN, LD
    PRESSLEY, J
    SMITH, MS
    OCALLAGHAN, WG
    ELLENBOGEN, KA
    CIRCULATION, 1984, 70 (04) : 412 - 412
  • [10] Comparison between his-bundle pacing and left bundle branch pacing in patients with atrioventricular block
    Hu, Yiran
    Li, Hui
    Gu, Min
    Hua, Wei
    Niu, Hongxia
    Zhang, Nixiao
    Liu, Xi
    Chen, Xuhua
    Hou, Cuihong
    Zhou, Xiaohong
    Zhang, Shu
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 63 - 73