Intra- and interobserver reliability of glenoid fracture classifications by Ideberg, Euler and AO

被引:7
|
作者
Gilbert, F. [1 ]
Eden, L. [1 ]
Meffert, R. [1 ]
Konietschke, F. [2 ]
Lotz, J. [3 ]
Bauer, L. [3 ]
Staab, W. [3 ]
机构
[1] Julius Maximilians Univ Wurzburg, Depr Trauma Hand Plast & Reconstruct Surg, Wurzburg, Germany
[2] Univ Texas Dallas, Dept Math Sci, Richardson, TX 75083 USA
[3] Univ Med Ctr Gottingen, Inst Diagnost & Intervent Radiol, Gottingen, Germany
来源
关键词
Scapula; Glenoid; Fracture; Classification; Diagnosis; Reliability; Comparison; ANTERIOR DISLOCATION; SCAPULAR FRACTURES; FOSSA; SHOULDER;
D O I
10.1186/s12891-018-2016-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Representing 3%-5% of shoulder girdle injuries scapula fractures are rare. Furthermore, approximately 1% of scapula fractures are intraarticularfractures of the glenoid fossa. Because of uncertain fracture morphology and limited experience, the treatment of glenoid fossa fractures is difficult. The glenoid fracture classification by Ideberg (1984) and Euler (1996) is still commonly used in literature. In 2013 a new glenoid fracture classification was introduced by the AO. The purpose of this study was to examine the new AO classification in clinical practice in comparison with the classifications by Ideberg and Euler. Methods: In total CT images of 84 patients with glenoid fossa fractures from 2005 to 2018 were included. Parasagittal, paracoronary and axial reconstructions were examined according to the classifications of Ideberg, Euler and the AO by 3 investigators (orthopedic surgeon, radiologist, student of medicine) at three individual time settings. Inter-and intraobserver reliability of the three classification systems were ascertained by computing Interand Intraclass (ICCs) correlation coefficients using Spearman's rank correlation coefficient, 95%-confidence intervals as well as F-tests for correlation coefficients. Results: Inter-and intraobserver reliability for the AO classification showed a perspicuous coherence (R = 0.74 and R = 0.79). Low to moderate intraobserver reliability for Ideberg (R = 0.46) and Euler classification (R = 0.41) was found. Furthermore, data show a low Interobserver reliability for both Ideberg and Euler classification (R < 0.2). Both the Inter-and Intraclass reliability using AO is significantly higher than those using Ideberg and Euler (p < 0.05). Using the new AO classification, it was possible to find a proper class for every glenoid fossa fracture. On average, according to Euler classification 10 of 84 fractures were not classifiable whereas to Ideberg classification 21 of 84 fractures were not classifiable. Conclusion: The new AO classification system introduced 2013 facilitates reliable grading of glenoid fossa fractures with high inter-and intraobserver reliability in 84 patients using CT images. It should possibly be applied in order to enable a valid, reliable and consistent academic description of glenoid fossa fractures. The established classifications by Euler and Ideberg are not capable of providing a similar reliability.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Intra- and Interobserver Agreement during the Assessment of the Different Stages of Root Development Using 4 Radiographic Classifications
    Plascencia, Hugo
    Diaz, Mariana
    Ordinola-Zapata, Ronald
    Vazquez-Sanchez, Maria Eugenia
    Juarez-Broon, Norberto
    Ruiz-Gutierrez, Aloysia
    Gascon, Gerardo
    Cruz, Alvaro
    [J]. JOURNAL OF ENDODONTICS, 2021, 47 (06) : 906 - 913
  • [32] Three-Dimensional Computed Tomography Reconstructions Do Not Improve the Interobserver Reliability of the AO/Orthopaedic Trauma Association and Young and Burgess Pelvic Fracture Classifications
    Byun, Seong-Eun
    Hwang, Jihyo
    Salameh, Motasem
    Tucker, Nicholas J.
    Hadeed, Michael
    Heare, Austin
    Stacey, Stephen C.
    Mauffrey, Cyril
    Parry, Joshua A.
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (06) : 1018 - 1022
  • [33] Three-Dimensional Computed Tomography Reconstructions Do Not Improve the Interobserver Reliability of the AO/Orthopaedic Trauma Association and Young and Burgess Pelvic Fracture Classifications
    Seong-Eun Byun
    Jihyo Hwang
    Motasem Salameh
    Nicholas J. Tucker
    Michael Hadeed
    Austin Heare
    Stephen C. Stacey
    Cyril Mauffrey
    Joshua A. Parry
    [J]. Indian Journal of Orthopaedics, 2022, 56 : 1018 - 1022
  • [34] Templating in uncemented total hip arthroplasty-on intra- and interobserver reliability and professional experience
    Strom, Nils J.
    Pripp, Are Hugo
    Reikeras, Olav
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5 (03)
  • [35] Evaluating the Endoscopic Reference Score for eosinophilic esophagitis: moderate to substantial intra- and interobserver reliability
    van Rhijn, Bram D.
    Warners, Marijn J.
    Curvers, Wouter L.
    van Lent, Anja U.
    Bekkali, Noor L.
    Takkenberg, R. Bart
    Kloek, Jaap J.
    Bergman, Jacques J. G. H. M.
    Fockens, Paul
    Bredenoord, Albert J.
    [J]. ENDOSCOPY, 2014, 46 (12) : 1049 - 1055
  • [36] Intra- and interobserver reliability in measuring aortic root rotation with cardiac magnetic resonance imaging
    Voortman, Marco
    Fitski, Wouter
    van Es, Jan
    Doggen, Carine J. M.
    Plonek, Tomasz
    von Birgelen, Clemens
    Wagenaar, Lodewijk J.
    [J]. CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2024, 14 (02) : 264 - 271
  • [37] The effect of additional video documentation to photo documentation in wrist arthroscopies on intra- and interobserver reliability
    Steffen Löw
    Thomas Pillukat
    Karl-Josef Prommersberger
    Jörg van Schoonhoven
    [J]. Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 433 - 438
  • [38] The effect of additional video documentation to photo documentation in wrist arthroscopies on intra- and interobserver reliability
    Loew, Steffen
    Pillukat, Thomas
    Prommersberger, Karl-Josef
    van Schoonhoven, Joerg
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (03) : 433 - 438
  • [39] Validity and intra- and interobserver reliability of an indirect volume measurements in patients with upper extremity lymphedema
    Meijer, RS
    Rietman, JS
    Geertzen, JHB
    Bosmans, JC
    Dijkstra, PU
    [J]. LYMPHOLOGY, 2004, 37 (03) : 127 - 133
  • [40] Intra- and Interobserver Reliability of Superb Microvascular Imaging (SMI) Doppler for Assessing Placental Microvasculature
    Garcia-Jimenez, Rocio
    Antonio Garcia-Mejido, Jose
    Valero, Irene
    Fernandez-Palacin, Ana
    Borrero, Carlota
    Antonio Sainz-Bueno, Jose
    [J]. CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2022, 49 (08):