Myocardial Blood Flow and Coronary Flow Reserve During 3 Years Following Bioresorbable Vascular Scaffold Versus Metallic Drug-Eluting Stent Implantation

被引:8
|
作者
Stuijfzand, Wijnand J. [1 ]
Schumacher, Stefan P. [1 ]
Driessen, Roel S. [1 ]
Lammertsma, Adriaan A. [2 ]
Bakker, Amber L. [1 ]
Rijnierse, Mischa T. [1 ]
van Rossum, Albert C. [1 ]
van de Ven, Peter M. [3 ]
Nap, Alexander [1 ]
Appelman, Yolande [1 ]
van Royen, Niels [4 ]
van Leeuwen, Maarten A. [5 ]
Lemkes, Jorrit S. [1 ]
Raijmakers, Pieter G. [2 ]
Knaapen, Paul [1 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Amsterdam UMC, Dept Cardiol, De Boelelaan 1117, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Amsterdam UMC, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Amsterdam UMC, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[4] Radboud Univ Nijmegen, Med Ctr, Dept Cardiol, Nijmegen, Netherlands
[5] Isala Heart Ctr, Dept Cardiol, Zwolle, Netherlands
关键词
OPTICAL COHERENCE TOMOGRAPHY; ABSORB II; OUTCOMES; ANGIOGRAPHY; VASOMOTION; SYSTEM; XIENCE;
D O I
10.1016/j.jcin.2019.03.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The randomized clinical VANISH (Impact of Vascular Reparative Therapy on Vasomotor Function and Myocardial Perfusion: A Randomized [15O] H2O PET/ CT Study) trial was conducted to assess quantitative myocardial blood flow (MBF) during resting, hyperemia, and cold pressor testing (CPT) with positron emission tomographic perfusion imaging after the implantation of a bioresorbable everolimus-eluting scaffold compared with a drug-eluting stent. BACKGROUND Long-term resorption of the bioresorbable everolimus-eluting scaffold reinstates normal vessel geometry, allowing natural regeneration of the newly formed endothelium with revival of vasomotor function. METHODS Sixty patients (18 to 65 years of age) with single-vessel disease and type A or B1 lesions were randomized in a 1-to-1 fashion. Approximately 1 month, 1 year, and 3 years after device implantation, patients underwent [15O] H2O cardiac positron emission tomography. The primary endpoint was the interaction of device type and evolution over time of hyperemic MBF, coronary flow reserve, or CPT reserve. At 3-year follow-up, control invasive coronary angiography with optical coherence tomography was performed. RESULTS Fifty-nine (98%), 56 (93%), and 51 (85%) patients successfully completed 1-month, 1-year, and 3-year follow-up positron emission tomography, respectively, and no culprit vessel events were registered during follow-up time. The primary study endpoint (i. e., interaction between device type and time) was nonsignificant for hyperemic MBF, CPT reserve, and coronary flow reserve (p > 0.05 for all). In all patients, hyperemic MBF decreased from 1 to 3 years (p 1/4 0.02), while coronary flow reserve was lower at 3-year follow-up compared with 1-month and 1-year follow-up (p 1/4 0.03 for both). After 3 years, percentage area stenosis measured with optical coherence tomography was higher within the bioresorbable everolimus-eluting scaffold compared with the drug-eluting stent (p 1/4 0.03). CONCLUSIONS The hypothesized beneficial effects of scaffold resorption did not translate to improved MBF during maximal hyperemia or endothelium-dependent vasodilation by CPT. (J Am Coll Cardiol Intv 2019; 12: 967-79) (c) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:967 / 979
页数:13
相关论文
共 50 条
  • [31] Two-year outcomes of bioresorbable vascular scaffold versus drug-eluting stents in coronary artery disease: a meta-analysis
    Nairooz, Ramez
    Saad, Marwan
    Sardar, Partha
    Aronow, Wilbert S.
    HEART, 2017, 103 (14) : 1096 - 1103
  • [32] Vascular Response Following Drug-Eluting Stent Implantation in Calcified Coronary Lesions: 2 Major Clinical Questions Emerged
    Kitabata, Hironori
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 41 : 61 - 62
  • [33] Real-World Bioresorbable Vascular Scaffold Experience Compared With Second-Generation Metallic Drug-Eluting Stents in Complex Coronary Lesions
    Okamoto, Naotaka
    Ueda, Hiroshi
    Yoshimura, Takahiro
    Chamaria, Surbhi
    Bhatheja, Samit
    Vengrenyuk, Yuliya
    Rabid, Samaria
    Barrientos, Yonandy
    Kapur, Vishal
    Barman, Nitin
    Sweeny, Joseph
    Baber, Usman
    Mehran, Roxana
    Sharma, Samin K.
    Kini, Annapoorna S.
    JOURNAL OF INVASIVE CARDIOLOGY, 2018, 30 (07): : 251 - 255
  • [34] Comparison of diagnostic accuracy of immediate angiography derived residual quantitative flow ratio after bioresorbable scaffold and drug eluting stent implantation
    Li, Zhengwei
    Zhan, Jiachen
    Han, Jia
    Fu, Guosheng
    Jin, Chongying
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2022, 23 (02)
  • [35] Effect of the Endothelial Shear Stress Patterns on Neointimal Proliferation Following Drug-Eluting Bioresorbable Vascular Scaffold Implantation An Optical Coherence Tomography Study
    Bourantas, Christos V.
    Papafaklis, Michail I.
    Kotsia, Anna
    Farooq, Vasim
    Muramatsu, Takashi
    Gomez-Lara, Josep
    Zhang, Yao-Jun
    Iqbal, Javaid
    Kalatzis, Fanis G.
    Naka, Katerina K.
    Fotiadis, Dimitrios I.
    Dorange, Cecile
    Wang, Jin
    Rapoza, Richard
    Garcia-Garcia, Hector M.
    Onuma, Yoshinobu
    Michalis, Lampros K.
    Serruys, Patrick W.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (03) : 315 - 324
  • [36] Implications of the local hemodynamic forces on vessel wall responses following drug-eluting bioresorbable vascular scaffold implantation: an optical coherence tomography analysis
    Bourantas, Christos
    Papafaklis, Michail I.
    Anna, Kotsia
    Farooq, Vasim
    Dorange, Cecile
    Fotiadis, Dimitrios I.
    Gomez Lara, Josep
    Michalis, Lampros
    Muramatsu, Takashi
    Naka, Katerina K.
    Onuma, Yoshinobu
    Rapoza, Richard
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B170 - B170
  • [37] The effects of bare metal versus drug-eluting stent implantation on circulating endothelial cells following percutaneous coronary intervention
    Jazi, Seyed Mohammad Hashemi
    Shafiei, Saeed
    Zarkesh-Esfahani, Seyed Hamid
    Vareki, Saman Maleki
    Javanmard, Shaghayegh Haghjooy
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2011, 16 (05): : 605 - 610
  • [38] Clinical Assessment of Myocardial Perfusion Imaging for the Patients with Insufficient Fractional Flow Reserve after Drug Eluting Stent Implantation
    Fukuzawa, S.
    Ikeda, A.
    Okino, S.
    Maekawa, J.
    Ichikawa, S.
    Uchiyama, T.
    Kuroiwa, N.
    Inagaki, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S199 - S199
  • [39] The elusive role of myocardial perfusion imaging for the patients with insufficient fractional flow reserve after drug eluting stent implantation
    Fukuzawa, S.
    Okino, S.
    Iwata, Y.
    Kuroiwa, N.
    Uchiyama, T.
    Inagaki, M.
    EUROPEAN HEART JOURNAL, 2018, 39 : 976 - 977
  • [40] Magnesium bioresorbable scaffold (Magmaris) versus polymer biodegradable ultrathin drug-eluting stent (Ultimaster) in acute coronary syndrome. Mid-term outcomes (2 years)
    Wlodarczak, Adrian
    Rola, Piotr
    Wlodarczak, Szymon
    Szudrowicz, Marek
    Jaroszewska-Pozorska, Joanna
    Barycki, Mateusz
    Furtan, Lukasz
    Kedzierska, Michalina
    Doroszko, Adrian
    Lesiak, Maciej
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2024, 20 (01): : 67 - 75