Effects of seismic isolation bearing with sliding mechanism on the response of bridge

被引:2
|
作者
Park, SK
Han, KB
机构
[1] Department of Civil Engineering, Sungkyunkwan University
关键词
D O I
10.1617/13871
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the seismic analysis and the modelling techniques have been introduced for aseismic performances assessment, when seismic isolation bearings are applied on a bridge. Nonlinear time-history analysis is carried out using finite element analysis program. In this study, El Centro earthquake (1940, N00W), Mexico earthquake (1985, N90W), and artificial earthquake are used as earthquake ground motions. The response of seismic isolated bridge is compared with that of a bridge using conventional POT bearings, after obtaining the displacements of the deck, the deformations of the piers, shear forces and moments of the bottoms of the piers. The results show that seismic isolation bearing could reduce earthquake forces. According to characteristics of input earthquake ground motions or combination method of materials, the effect of seismic isolation bearings becomes different. Especially EDF (Electricite De France) system which is seismic isolation bearing with sliding mechanism, could reduce earthquake forces well.
引用
收藏
页码:412 / 421
页数:10
相关论文
共 50 条
  • [31] Seismic response with collision of skew bridge and curved one supported by rubber bearing
    Ijima, K
    Obiya, H
    Aramaki, G
    STRUCTURAL ENGINEERING AND MECHANICS, VOLS 1 AND 2, 1999, : 777 - 782
  • [32] Mechanism and devices for 3-dimensional seismic isolation bearing in vertical direction
    Li, Xiong-Yan
    Xue, Su-Duo
    Beijing Gongye Daxue Xuebao / Journal of Beijing University of Technology, 2008, 34 (10): : 1043 - 1047
  • [33] Identification of sliding plate bridge bearing malfunction and its effects on bridge structure under service conditions
    Waqas, Hafiz Ahmed
    Su, Di
    Nagayama, Tomonori
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2024, 14 (04) : 947 - 961
  • [34] Identification of sliding plate bridge bearing malfunction and its effects on bridge structure under service conditions
    Hafiz Ahmed Waqas
    Di Su
    Tomonori Nagayama
    Journal of Civil Structural Health Monitoring, 2024, 14 : 947 - 961
  • [35] Seismic isolation of the Jamuna multipurpose bridge
    Castellano, MG
    Cestarollo, A
    EARTHQUAKE RESISTANT ENGINEERING STRUCTURES II, 1999, : 647 - 656
  • [36] Bridge earthquake protection with seismic isolation
    Feng, X.
    Technical Council on Lifeline Earthquake Engineering Monograph, 1999, (16): : 267 - 275
  • [37] Bridge earthquake protection with seismic isolation
    Feng, X
    OPTIMIZING POST-EARTHQUAKE LIFELINE SYSTEM RELIABILITY, 1999, (16): : 267 - 275
  • [38] Development of rocking isolation bearing system (RIBS) to control excessive seismic responses of bridge structures
    He, Xinhao
    Unjoh, Shigeki
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2022, 51 (02): : 369 - 392
  • [39] Effects of the isolation parameters on the seismic response of steel frames
    Deringol, Ahmet H.
    Bilgin, Huseyin
    EARTHQUAKES AND STRUCTURES, 2018, 15 (03) : 319 - 334
  • [40] Reduction of seismic response of mechanical system by base isolation system with friction bearing
    Aoki, Shigeru
    Tominaga, Kazutoshi
    Nishimura, Tadashi
    Kanazawa, Mitsuo
    Nakanishi, Yuji
    Otaka, Takeshi
    Inagaki, Mitsuyoshi
    Kawaguchi, Sumio
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2007, VOL 8: SEISMIC ENGINEERING, 2007, : 177 - 183