Sensorless variable speed operation of doubly-fed reluctance wind generators

被引:4
|
作者
Jovanovic, Milutin [1 ]
Ademi, Sul [2 ]
Binns, Richard [1 ]
机构
[1] Northumbria Univ, Fac Engn & Environm, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Warwick, Warwick Mfg Grp, Coventry, W Midlands, England
关键词
rotors; reluctance generators; machine vector control; angular velocity control; power convertors; brushless machines; machine control; power generation control; wind power plants; wind turbines; asynchronous generators; shafts; comprehensive comparative simulation; sensorless controller; precise speed reference tracking; intrinsically decoupled real power responses; reactive power responses; grid-connected winding; typical variable loading profiles; narrow speed ranges; laboratory emulated wind turbine; sensorless variable speed operation; doubly-fed reluctance wind generators; improved flux vector orientated control scheme; more robust flux vector orientated control scheme; emerging doubly-fed reluctance generator; shaft angular position; computer-simulated; fractional power electronics converter rating; promising medium-speed brushless machine technology; industrial communities; appealing economical solution; compromised reliability; high maintenance requirements; conventional wound rotor doubly-fed induction generators; commercial wind turbines; FED INDUCTION MACHINE; CONTROL SCHEME; DESIGN; TURBINES; PERFORMANCE; DFIG; MRAS;
D O I
10.1049/iet-rpg.2020.0021
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An improved and more robust flux vector orientated control scheme for an emerging doubly-fed reluctance generator without a shaft angular position or velocity sensor has been proposed, computer-simulated, and experimentally verified. Whilst retaining the cost and other advantages of using a fractional power electronics converter rating, this promising medium-speed brushless machine technology has been viewed by research and industrial communities as an appealing economical solution for the compromised reliability and high maintenance requirements associated with the presence of slip rings, brushes, and the failures prone three-stage gearbox of conventional wound rotor doubly-fed induction generators, traditionally deployed for commercial wind turbines. The comprehensive comparative simulation and test results obtained have been shown to agree very well undoubtedly demonstrating the good overall performance of the sensorless controller. A precise speed reference tracking with smooth, intrinsically decoupled real and reactive power responses of the grid-connected winding has been achieved for the typical variable loading profiles and narrow speed ranges (e.g. around $2:1$2:1 or so) of a laboratory emulated wind turbine.
引用
收藏
页码:2810 / 2819
页数:10
相关论文
共 50 条
  • [31] Improved energy conversion for doubly-fed wind generators
    Smith, S
    Todd, R
    Barnes, M
    Tavner, PJ
    CONFERENCE RECORD OF THE 2005 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2005, : 2288 - 2295
  • [32] Sensorless Speed Estimation of Brushless Doubly-Fed Reluctance Generator Using Active Power Based MRAS
    Kumar, Mukesh
    Das, Sukanta
    Kiran, Karuna
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (08) : 7878 - 7886
  • [33] Controller Performance of Variable Speed Wind Driven Doubly-Fed Induction Generator
    Alaboudy, Ali H. Kasem
    Azmy, Ahmed M.
    Abdellatif, Walid S. E.
    2015 SAUDI ARABIA SMART GRID CONFERENCE (SASG), 2015,
  • [34] Parameter Independent Vector Control of Brushless Doubly-Fed Reluctance Generators
    Jovanovic, Milutin
    Busawon, Krishna
    Ademi, Sul
    Jin, Shi
    PROCEEDINGS OF THE 2016 4TH INTERNATIONAL SYMPOSIUM ON ENVIRONMENTAL FRIENDLY ENERGIES AND APPLICATIONS (EFEA), 2016,
  • [35] Variable-speed wind turbines with doubly-fed induction generators Part IV: Uninterrupted operation features at grid faults with converter control coordination
    Akhmatov, Vladislav
    Wind Engineering, 2003, 27 (06) : 519 - 529
  • [36] Application of ADRC in Variable-Speed Constant-Frequency Wind Energy Generation with Doubly-Fed Induction Generators
    Zhou Xuesong
    Li Chao
    Ma Youjie
    Li Ji
    Yu Yang
    PROCEEDINGS OF THE 29TH CHINESE CONTROL CONFERENCE, 2010, : 6061 - 6065
  • [37] Theoretical and Experimental Evaluation of Vector Control for Doubly-Fed Reluctance Generators
    Ademi, Sul
    Jovanovic, Milutin
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2014, : 936 - 942
  • [38] Speed Sensorless Direct Torque Control of Brushless Doubly-Fed Generator for Wind Power Generation
    Jin, Shi
    Zhang, Fengge
    Wang, Xiuping
    2009 INTERNATIONAL CONFERENCE ON APPLIED SUPERCONDUCTIVITY AND ELECTROMAGNETIC DEVICES, 2009, : 300 - 303
  • [39] Design of a Doubly-Fed Reluctance Machine for Wind Energy Generation
    Cao, Wenping
    Huang, Xiaoyan
    French, Ian
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2443 - +
  • [40] Maximum Torque per Inverter Ampere Control of Brushless Doubly-Fed Reluctance Generators for Wind Turbines
    Ademi, Sul
    Jovanovi, Milutin
    2014 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2014, : 883 - 888