Chondrocyte viability in press-fit cryopreserved osteochondral allografts

被引:37
|
作者
Gole, MD
Poulsen, D
Marzo, JM
Ko, SH
Ziv, I
机构
[1] Vet Adm Western New York Healthcare Syst, Orthopaed Sect, Buffalo, NY 14215 USA
[2] SUNY Buffalo, Dept Physiol & Biophys, Buffalo, NY 14214 USA
[3] Millard Fillmore Hosp, Kaleida Hlth Syst, Buffalo, NY 14209 USA
关键词
articular cartilage; transplantation; press-fit; cryopreservation; viability; load-bearing;
D O I
10.1016/j.orthres.2003.11.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The viability of chondrocytes in press-fit glycerol-preserved osteochondral allografts was compared to that in fresh autografts, after transplantation into load-bearing and non-load-bearing sites in mature sheep stifle joints. We used macroscopic grading, tonometer pen indentation testing, histology, sulfate uptake and viability as determined by confocal-microscopy to assess cartilage condition. Despite there being no statistical differences between macroscopic appearance and tonometer testing of all grafts, confocal microscopy and histology demonstrated a positive effect of load-bearing placement on cryopreserved osteochondral allografts. Allografts transplanted into load-bearing sites demonstrated superior confocal microscopy-measured chondrocyte viability (77% +/- 17%SD) than those transplanted into non-load-bearing sites (25% +/- 2%). Load-bearing effect was not seen in autografts (78% +/- 15%), and was comparable in adjacent cartilage (83% +/- 9%). Similarly, load-bearing allografts demonstrated histological scoring closer to that of autografts and adjacent cartilage, all of which fared significantly better than non-load-bearing allografts. Load-bearing allografts had a greater amount of fibrocartilage than autografts or adjacent cartilage but less fibrocartilage than nonload-bearing allografts. Both autografts and allografts had non-significant increases in metabolism compared to adjacent cartilage as measured by sulfate-uptake. Load-bearing placement improved chondrocyte viability of glycerol cryopreserved osteochondral allograft following a press-fit implantation. Published by Elsevier Ltd. on behalf of orthopaedic Research Society.
引用
收藏
页码:781 / 787
页数:7
相关论文
共 50 条
  • [31] Press-fit hip arthroplasty - A European alternative
    Romagnoli, S
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (04): : 108 - 112
  • [32] PRESS-FIT PIN TECHNOLOGY FOR BELLPAC BACKPLANES
    EDWARDS, WJ
    HUDSON, GD
    [J]. WESTERN ELECTRIC ENGINEER, 1983, 27 (03): : 40 - 47
  • [33] The influence of bone damage on press-fit mechanics
    Bishop, Nicholas E.
    Hoehn, Jan-Christian
    Rothstock, Stephan
    Damm, Niklas B.
    Morlock, Michael M.
    [J]. JOURNAL OF BIOMECHANICS, 2014, 47 (06) : 1472 - 1478
  • [34] Large osteochondral defects of the femoral condyle: press-fit transplantation of the posterior femoral condyle (MEGA-OATS)
    Jens D. Agneskirchner
    Peter Brucker
    Andreas Burkart
    Andreas B. Imhoff
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2002, 10 : 160 - 168
  • [35] Large osteochondral defects of the femoral condyle: press-fit transplantation of the posterior femoral condyle (MEGA-OATS)
    Agneskirchner, JD
    Brucker, P
    Burkart, A
    Imhoff, AB
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (03) : 160 - 168
  • [36] Ultrasonic quality control of press-fit joints
    Budenkov, G. A.
    Ivannikov, V. P.
    Kabakova, A. V.
    Strizhak, V. A.
    [J]. RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2009, 45 (08) : 575 - 581
  • [37] THE PRESS-FIT IMPLANT IMPRESSION COPING TECHNIQUE
    Nissan, Joseph
    Ghelfan, Oded
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (06): : 413 - 414
  • [38] Fluorescent viability stains overestimate chondrocyte viability in osteoarticular allografts
    Lightfoot, Andrew
    Martin, James
    Amendola, Annunziato
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (11): : 1817 - 1823
  • [39] Training the Transmission Capacity of Press-Fit Connections
    Gropp, Herbert
    [J]. WELLE-NABE-VERBINDUNGEN: GESTALTUNG - FERTIGUNG - ANWENDUNGEN MIT FACHAUSSTELLUNG, 2012, 2012, 2176 : 19 - 29
  • [40] Arthroscopic ACL Reconstruction in Press-Fit Technique
    Halder, Andreas M.
    Marx, Axel
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2013, 28 (02) : 141 - 144