A flow-through potentiometric sensor for an integrated microdialysis system

被引:12
|
作者
Pijanowska, DG
Sprenkels, A
van der Linden, H
Olthuis, W
Bergveld, P
van den Berg, A
机构
[1] Univ Twente, MESA, Res Inst, NL-7500 AE Enschede, Netherlands
[2] Polish Acad Sci, Inst Biocybernet & Biomed Engn, PL-02109 Warsaw, Poland
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 103卷 / 1-2期
关键词
potentiometric sensor; flow-through system; potassium sensor; microdialysis; lab-on-a-chip; mu TAS;
D O I
10.1016/j.snb.2004.04.108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the performance of a flow-through potentiometric sensor based on a semi-permeable dialysis tubing implemented in silicon, is presented. The sensor is designed as part of a lab-on-a-chip system and has been successfully incorporated into an integrated microdialysis system. Results of a potassium sensor, operating stand-alone, and as part of the integrated system are presented. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:350 / 355
页数:6
相关论文
共 50 条
  • [1] A generic design of a flow-through potentiometric sensor array
    Böhm, S
    Olthuis, W
    Bergveld, P
    MIKROCHIMICA ACTA, 2000, 134 (3-4) : 237 - 243
  • [2] Novel design of a planar flow-through potentiometric sensor
    Guagneli, Luca
    Mousavi, Zekra
    Sokalski, Tomasz
    Leito, Ivo
    Bobacka, Johan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 923
  • [3] A novel flow-through microdialysis separation unit with integrated differential potentiometric detection for the determination of chloride in soil samples
    Miró, M
    Frenzel, W
    ANALYST, 2003, 128 (10) : 1291 - 1297
  • [4] On-chip microdialysis system with flow-through sensing components
    Hsieh, Yi-Cheng
    Zahn, Jeffrey D.
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2422 - 2428
  • [5] Flow-through Potentiometric Residual Chlorine Sensor Using Activated Carbon Chamber Sandwiched Filter Electrode System
    Kakitani, Yui
    Iiyama, Masamitsu
    Takayanagi, Toshio
    Mizuguchi, Hitoshi
    BUNSEKI KAGAKU, 2024, 73 (09) : 545 - 551
  • [6] FLOW-THROUGH NAD SENSOR
    MALINAUSKAS, AA
    KULYS, JJ
    BIOTECHNOLOGY AND BIOENGINEERING, 1979, 21 (03) : 513 - 518
  • [7] POTENTIOMETRIC NITRATE ANALYSIS - A FLOW-THROUGH ELECTRODE UNIT
    MILHAM, PJ
    ANALYST, 1970, 95 (1133) : 758 - &
  • [8] DETERMINATION OF COBALT IN WATER USING A FLOW-THROUGH SENSOR SYSTEM
    TRUTNEVA, LM
    SHVOEVA, OP
    SAVVIN, SB
    JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 49 (05) : 426 - 429
  • [9] The value of a flow-through entity in an integrated corporate tax system
    Edwards, Alexander
    Shevlin, Terry
    JOURNAL OF FINANCIAL ECONOMICS, 2011, 101 (02) : 473 - 491
  • [10] A novel flow-through planar solid contact sensor for the determination of lead with potentiometric anionic response
    Kamel, Ayman H.
    ELECTROANALYSIS, 2007, 19 (23) : 2419 - 2427