Novel design of a planar flow-through potentiometric sensor

被引:3
|
作者
Guagneli, Luca [1 ]
Mousavi, Zekra [1 ]
Sokalski, Tomasz [1 ]
Leito, Ivo [2 ]
Bobacka, Johan [1 ]
机构
[1] Abo Akad Univ, Johan Gadolin Proc Chem Ctr, Lab Mol Sci & Engn, Henriksgatan 2, Turku 20500, Finland
[2] Univ Tartu, Inst Chem, Ravila 14a, EE-50411 Tartu, Estonia
关键词
Potentiometric sensor; Solid-contact; Planar electrode; Potassium ion-selective electrode; Flow-through design; ION-SELECTIVE ELECTRODES; SODIUM;
D O I
10.1016/j.jelechem.2022.116785
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel planar electrode for flow-through potentiometric sensing is presented in this work. Planar and concen-tric potassium solid-contact ion-selective electrodes (K+-SCISEs) were designed and studied using potentiom-etry and electrochemical impedance spectroscopy (EIS). The K+-SCISE consisted of a neutral carrier PVC-based ion-selective membrane with valinomycin as ionophore, carbon cloth as ion-to-electron transducer, and a gold wire as electronic conductor, all incased in a polycarbonate support. The prepared electrodes showed a stable and reproducible potentiometric response. The average slopes for three identical flow-through K+-SCISEs, cal-ibrated once per day during five days (n = 15), was 57.2 mV/decade (SD = 0.9 mV/decade). The correspond-ing standard potential of the electrodes during five days (n = 15) was 417 mV (SD = 3.6 mV). The water-layer test showed that the ion-selective membrane/carbon cloth interface was not subject to the formation of a water layer. The electrodes had selectivity coefficients comparable to the values obtained from the literature. The resistance of the ion-selective membrane, determined by EIS, was in the range of 45-250 M omega for the planar electrode geometries studied in this work.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A generic design of a flow-through potentiometric sensor array
    Böhm, S
    Olthuis, W
    Bergveld, P
    MIKROCHIMICA ACTA, 2000, 134 (3-4) : 237 - 243
  • [2] A novel flow-through planar solid contact sensor for the determination of lead with potentiometric anionic response
    Kamel, Ayman H.
    ELECTROANALYSIS, 2007, 19 (23) : 2419 - 2427
  • [3] A flow-through potentiometric sensor for an integrated microdialysis system
    Pijanowska, DG
    Sprenkels, A
    van der Linden, H
    Olthuis, W
    Bergveld, P
    van den Berg, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 103 (1-2): : 350 - 355
  • [4] A novel chemiluminescence flow-through sensor for the determination of analgin
    Yu-Ming Huang
    Chao Zhang
    Xin-Rong Zhang
    Zhu-Jun Zhang
    Fresenius' Journal of Analytical Chemistry, 1999, 365 : 381 - 383
  • [5] A novel chemiluminescence flow-through sensor for the determination of analgin
    Huang, YM
    Zhang, C
    Zhang, XR
    Zhang, ZJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (04): : 381 - 383
  • [6] FLOW-THROUGH NAD SENSOR
    MALINAUSKAS, AA
    KULYS, JJ
    BIOTECHNOLOGY AND BIOENGINEERING, 1979, 21 (03) : 513 - 518
  • [7] POTENTIOMETRIC NITRATE ANALYSIS - A FLOW-THROUGH ELECTRODE UNIT
    MILHAM, PJ
    ANALYST, 1970, 95 (1133) : 758 - &
  • [8] Novel micro flow-through cell pH-ISFET integrated sensor
    Ding, Xinfang
    Dian Zi Qi Jian/Journal of Electron Devices, 1996, 19 (03):
  • [9] A novel planar miniaturized potentiometric sensor for flow injection analysis of nitrates in wastewaters, fertilizers and pharmaceuticals
    Hassan, Saad S. M.
    Sayour, H. E. M.
    Al-Mehrezi, Saeed S.
    ANALYTICA CHIMICA ACTA, 2007, 581 (01) : 13 - 18
  • [10] FLUOROMETRIC FLOW-THROUGH SENSOR FOR THE DETERMINATION OF PYRIDOXAL
    CHEN, DH
    DECASTRO, MDL
    VALCARCEL, M
    MICROCHEMICAL JOURNAL, 1991, 44 (02) : 215 - 221