Catheter-Based Closure of Atrial Septal Defects in the Oval Fossa With the Amplatzer® Device in Patients in Their First or Second Year of Life

被引:12
|
作者
Fischer, G. [1 ]
Smevik, B. [2 ]
Kramer, H. H. [1 ]
Bjornstad, P. G. [3 ]
机构
[1] Univ Med Ctr Schleswig Holstein, Dept Pediat Cardiol, D-24105 Kiel, Germany
[2] Aker Univ Hosp, Rikshosp, Sect Pediat Radiol, Div Med Imaging & Intervent, Oslo, Norway
[3] Aker Univ Hosp, Rikshosp, Pediat Clin, Dept Pediat Cardiol, Oslo, Norway
关键词
catheterization; infants; therapy; TRANSCATHETER CLOSURE; INTERVENTIONAL CLOSURE; SYMPTOMATIC CHILDREN; HEART-FAILURE; FOLLOW-UP; EXPERIENCE; OCCLUDER; IMPROVEMENT; ADULTS;
D O I
10.1002/ccd.21866
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To assess feasibility, safety, and efficacy of the use of Amplatzer (R) occluders in closure of atrial septal defects (ASD) in children in the first 2 years of life. Background: Although scattered reports on such closure have been published, no agreement consists on the policy. Methods: In 654 patients of all ages, closure was achieved in 632 (96.6%). Data were analyzed retrospectively in all 71 children where an attempt had been made to close the ASD before their second birthday. Results: Median age and body weight were 17.2 months (range 3.9-23.8) and 10.0 kg (range 3.8-14.5), respectively. Median fluoroscopy time was 13.6 min and median device size 15 mm. Successful closure was achieved in 68 children (95.8%). Three times the procedure was aborted: in one, the device repeatedly straddled the septum; in the other two, a small left atrium restricted the movement of the left-sided disc. One device embolized and was reimplanted after retrieval. One infant with multiple disorders died 6 days after closure from acute sepsis probably unrelated to the procedure. No other complications occurred. Only trivial shunts closing with time were registered during follow-up. Symptomatic patients profited markedly from closure. Conclusion: The results and complications of ASD closure with the Amplatzer (R) device in patients in their first 2 years of life compare favorably with procedures in older patients, provided that the size of the septum and the dimensions in the left atrium are taken into consideration when selecting the size of the device. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:949 / 955
页数:7
相关论文
共 50 条
  • [21] Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder
    Divekar, A
    Gaamangwe, T
    Shaikh, N
    Raabe, M
    Ducas, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (08) : 1213 - 1218
  • [22] Transcatheter closure of atrial septal defects in the oval fossa: is the method applicable in small children?
    Bjornstad, PG
    Holmstrom, H
    Smevik, B
    Tonnessen, TI
    Fosse, E
    CARDIOLOGY IN THE YOUNG, 2002, 12 (04) : 352 - 356
  • [23] Catheter-based closure of an atrial septal defect in scimitar syndrome
    Odland, Hans H.
    Smevik, Bjarne
    Bjornstad, Per G.
    PEDIATRIC CARDIOLOGY, 2006, 27 (04) : 500 - 502
  • [24] Catheter-Based Closure of an Atrial Septal Defect in Scimitar Syndrome
    Hans H. Odland
    Bjarne Smevik
    Per G. Bjørnstad
    Pediatric Cardiology, 2006, 27 : 500 - 502
  • [25] Platelet activation is increased in patients with atrial septal defects suitable for transcatheter closure with the amplatzer device
    Mackie, E
    Dawson, M
    McKenzie, A
    Hillis, WS
    EUROPEAN HEART JOURNAL, 2003, 24 : 96 - 96
  • [26] Predictors of residual defects following closure of defects in the oval fossa using the Amplatzer device: echocardiography recapitulates morphometry
    Balaguru, D
    Anderson, RH
    Rosenthal, GL
    Cook, AC
    Radtke, WAK
    Shirali, GS
    CARDIOLOGY IN THE YOUNG, 2003, 13 (04) : 352 - 360
  • [27] Platelet activation is increased in patients with atrial septal defects suitable for transcatheter closure with the amplatzer device
    Mackie, E
    Dawson, M
    McKenzie, A
    Hillis, WS
    HEART, 2003, 89 : A12 - A13
  • [28] A Novel Method of Hybrid Intraoperative Catheter-Based Closure of Ventricular Septal Defects Using the Amplatzer® PDA Occluder
    Neukamm, Christian
    Bjornstad, Per G.
    Fischer, Gunther
    Smevik, Bjarne
    Lindberg, Harald L.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (04) : 557 - 563
  • [29] Left atrial hybrid closure of muscular ventricular septal defects with the Amplatzer device
    Baird, Christopher W.
    Stern, Herbert
    Watts, Larry
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (03): : 779 - 780
  • [30] Comparison of results and complications of surgical and amplatzer device closure of atrial septal defects
    Berger, F
    Vogel, M
    Alexi-Meskishvili, V
    Lange, PE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (04): : 674 - 678