A digital ion trap mass spectrometer coupled with atmospheric pressure ion sources

被引:119
|
作者
Ding, L [1 ]
Sudakov, M [1 ]
Brancia, FL [1 ]
Giles, R [1 ]
Kumashiro, S [1 ]
机构
[1] Shimadzu Res Lab Europe Ltd, Manchester M17 1GP, Lancs, England
来源
JOURNAL OF MASS SPECTROMETRY | 2004年 / 39卷 / 05期
关键词
quadrupole ion trap; digital ion trap; resonance ejection; resolution; precursor isolation; tandem mass spectrometry; atmospheric pressure ionization;
D O I
10.1002/jms.637
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In a digital ion trap (DIT), the quadrupole trapping and excitation waveforms are generated by the rapid switching between discrete d.c. voltage levels. As the timing of the switch can be controlled precisely by digital circuitry, the approach provides an opportunity to generate mass spectra by means of a frequency scan in contrast to the conventional voltage scan, thus providing a wider mass range of analysis. An instrument has been constructed which employs a 'non-stretched' ion trap and the field fault around the aperture of the end-cap electrode can be corrected electronically using a field-adjusting electrode. The ion trap was coupled with electrospray ionization (ESI) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) sources to demonstrate the capability of the digital method. AP-MALDI mass spectra of singly charged ions with mass-to-charge ratios upto 17 000 Th were generated using a trapping voltage of only 1000 V. Forward and reverse mass scans at resolutions up to 19 000 and precursor ion isolation at resolutions up to 3500 with subsequent tandem mass spectrometric analysis were demonstrated. The method of generating the digital waveforms and period scan is described. Discussion of the issues of mass range, scan speed, ion trapping efficiency and collision-induced dissociation efficiency are also provided. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:471 / 484
页数:14
相关论文
共 50 条
  • [31] Validation of the ozone plus tetramethylethylene reaction using an atmospheric pressure flow reactor/ion trap mass spectrometer
    Wedian, Fadel Z.
    Atkinson, Dean B.
    JOURNAL OF ATMOSPHERIC CHEMISTRY, 2010, 66 (1-2) : 65 - 80
  • [32] Influence of the coupling between an atmospheric pressure ion mobility spectrometer and the low pressure ion inlet of a mass spectrometer on the mobility measurement
    Gunzer, Frank
    2016 INTERNATIONAL CONFERENCE ON FRONTIERS OF SENSORS TECHNOLOGIES (ICFST 2016), 2016, 59
  • [33] Linear ion trap/Orbitrap mass spectrometer
    Erickson, B
    ANALYTICAL CHEMISTRY, 2006, 78 (07) : 2089 - 2089
  • [34] Control system for an ion trap mass spectrometer
    Hopkins, Derek
    Alexander, Michael
    Swanson, Kenneth
    Buschbach, Michael
    Scientific Computing and Instrumentation, 2004, 21 (05): : 18 - 20
  • [35] A new linear ion trap mass spectrometer
    Hager, JW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) : 512 - 526
  • [36] A hyperboloid mass spectrometer with a monopolar ion trap
    E. V. Mamontov
    D. A. Ivlev
    Instruments and Experimental Techniques, 2000, 43 : 635 - 639
  • [37] Discrimination in mass spectrometer ion sources
    Coggeshall, ND
    JOURNAL OF CHEMICAL PHYSICS, 1942, 12 (01): : 19 - 23
  • [38] Mass spectrometer based on the bounded ion trap
    Mamontov, EV
    Ivlev, DA
    JOURNAL DE PHYSIQUE IV, 2000, 10 (P5): : 223 - 225
  • [39] An electrostatic autoresonant ion trap mass spectrometer
    Ermakov, A. V.
    Hinch, B. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (01):
  • [40] Handheld rectilinear ion trap mass spectrometer
    Gao, Liang
    Song, Qingyu
    Patterson, Garth E.
    Cooks, R. Graham
    Ouyang, Zheng
    ANALYTICAL CHEMISTRY, 2006, 78 (17) : 5994 - 6002