Coronal reformations of the chest on 64-row multi-detector row CT: Evaluation of image quality in comparison with 16-, 8-and 4-row multi-detector row CT

被引:13
|
作者
Nishino, Mizuki [1 ]
Kubo, Takeshi [1 ]
Kataoka, Milliam L. [1 ]
Raptopoulos, Vassilios [1 ]
Hatabu, Hiroto [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
chest; multi-detector row CT; coronal reformations; MPR; thorax;
D O I
10.1016/j.ejrad.2006.02.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate image quality of coronal reformations of chest performed on 64-row MDCT in comparison with 16-, 8- and 4-row MDCT. Materials and methods: Consecutive patients who underwent pulmonary CT angiography using four different MDCT scanners were retrospectively studied with IRB approval: (1) n = 30,64-row MDCT; (2) n = 30,16-row MDCT; (3) n = 30, 8-row MDCT; (4) n = 30,4-row MDCT. Coronal reformatted images (2 mm thickness and 2 mm intervals for 64-row MDCT; 5 mm thickness and 5 mm intervals for 16-, 8- and 4-row MDCT) were evaluated by consensus reading of two board-certified radiologists who were blinded to scanner type. The image quality of overall chest appearance and individual thoracic structures including heart, aorta and pulmonary arteries was graded using five-point scale. Grades from four different scanners were compared using Kruskal-Wallis test. A second evaluation was performed in 48 randomly selected patients (12 patients for each scanner). Reproducibility was assessed using weighted-kappa analysis. Result: Significant reproducibility was observed between the first and second evaluations in 48 patients both for image quality of overall chest (weighted kappa = 0.826) and each thoracic structure (mean weighted kappa = 0.803; range, 0.729-0.858). Image quality of overall chest and individual thoracic structures differed significantly among four different MDCT groups, with 64-row MDCT having the highest grades, followed by 16-, 8- and 4-row MDCT (mean grades for overall chest in each scanner: 3.9, 3.0, 2.4 and 1.9, respectively) (P < 0.0001 for overall chest and each thoracic structure). Conclusion: When comparing coronal reformations of chest using four different MDCT scanners, the 64-row MDCT had the highest image quality for overall chest appearance and individual thoracic structures, followed by 16-, 8- and finally 4-row MDCT. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [21] Application of multi-detector row helical scanning to postmyelographic CT
    Kazuhiro Tsuchiya
    Shichiro Katase
    Chinatsu Aoki
    Junichi Hachiya
    European Radiology, 2003, 13 : 1438 - 1443
  • [22] Multi-Detector Row CT Angiography of the Neck in Blunt Trauma
    Munera, Felipe
    Foley, Mark
    Chokshi, Falgun H.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2012, 50 (01) : 59 - +
  • [23] Acute aortic syndromes: Role of multi-detector row CT
    Salvolini, Luca
    Renda, Pietro
    Fiore, Davide
    Scaglione, Mariano
    Piccoli, GianPiero
    Giovagnoni, Andrea
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (03) : 350 - 358
  • [24] Orthopedic hardware complications diagnosed with multi-detector row CT
    Ohashi, K
    El-Khoury, GY
    Bennett, DL
    Restrepo, JM
    Berbaum, KS
    RADIOLOGY, 2005, 237 (02) : 570 - 577
  • [25] Virtual endoscopy of dogs using multi-detector row CT
    Yamada, Kazutaka
    Morimoto, Manabu
    Kishimoto, Miori
    Wisner, Erik R.
    VETERINARY RADIOLOGY & ULTRASOUND, 2007, 48 (04) : 318 - 322
  • [26] Multi-detector row CT angiography in patients with abdominal angina
    Cademartiri, F
    Raaijmakers, RHJM
    Kuiper, JW
    van Dijk, LC
    Pattynama, PMT
    Krestin, GP
    RADIOGRAPHICS, 2004, 24 (04) : 969 - 984
  • [27] Multi-detector row CT of pancreatic islet cell tumors
    Horton, Karen M.
    Hruban, Ralph H.
    Yeo, Charles
    Fishman, Elliot K.
    RADIOGRAPHICS, 2006, 26 (02) : 453 - U10
  • [28] Multi-detector row CT: Principles and practice for abdominal applications
    Saini, S
    RADIOLOGY, 2004, 233 (02) : 323 - 327
  • [29] Recent Technologic Advances in Multi-Detector Row Cardiac CT
    Halliburton, Sandra Simon
    CARDIOLOGY CLINICS, 2009, 27 (04) : 655 - +
  • [30] Application of multi-detector row helical scanning to postmyelographic CT
    Tsuchiya, K
    Katase, S
    Aoki, C
    Hachiya, J
    EUROPEAN RADIOLOGY, 2003, 13 (06) : 1438 - 1443