Validation of a HPLC/MS method for simultaneous quantification of clonidine, morphine and its metabolites in human plasma

被引:6
|
作者
Tang, Fei [1 ,2 ]
Bada, Henrietta [3 ]
Ng, Chee M. [1 ]
Leggas, Markos [1 ,2 ]
机构
[1] Univ Kentucky, Dept Pharmaceut Sci, Lexington, KY 40536 USA
[2] Univ Kentucky, Ctr Pharmaceut Res & Innovat, Coll Pharm, Lexington, KY 40536 USA
[3] Univ Kentucky, Coll Med, Dept Pediat, Lexington, KY 40536 USA
基金
美国国家卫生研究院;
关键词
clonidine; LC-MS; MS; method validation; morphine; neonatal abstinence syndrome; solid-phase extraction; NEONATAL ABSTINENCE SYNDROME; LC-MS/MS METHOD; UNITED-STATES; LONG-TERM; PHARMACOKINETICS; THERAPY; BIOEQUIVALENCE; HYDROCHLORIDE; PREVENTION; MIDAZOLAM;
D O I
10.1002/bmc.4527
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantification of morphine, morphine's major metabolites morphine-3-glucuronide and morphine-6-glucuronide, and clonidine, to support the pharmacokinetic analysis of an ongoing double-blinded randomized clinical trial that compares the use of morphine and clonidine in infants diagnosed with neonatal abstinence syndrome. Plasma samples were processed by solid-phase extraction and separated on an Inertsil ODS-3 (4 mu m) column using an 0.1% formic acid in water-0.1% formic acid in methanol gradient. Detection of the analytes was conducted in the positive multiple reaction monitoring mode. The range of quantitation was 1-1000 ng/mL for morphine, morphine-3-glucuronide and morphine-6-glucuronide, and 0.25-100 ng/mL for clonidine. Intra-day and inter-day accuracy and precision were <= 15% for all analytes across the quantitation range. Extraction recovery rates were >= 94% for morphine, >= 90% for M3G, >= 87% for M6G and >= 79% for clonidine. Matrix effect ranged from 85-94% for clonidine to 101-106% for M3G. The method fulfilled all predetermined acceptance criteria and required only 100 mu L of starting plasma volume. Furthermore, it was successfully applied to 30 clinical trial plasma samples.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Novel LC-MS/MS method for the quantification of silodosin and its metabolites in human plasma
    Shah, Priyanka A.
    Shrivastav, Pranav S.
    BIOANALYSIS, 2018, 10 (01) : 7 - 10
  • [22] Validation of a HPLC-ESI MS/MS method for the determination of clonidine in human plasma and its application in a bioequivalence study in Chinese healthy volunteers
    Zhuang, Jialang
    Chen, Jiangying
    Wang, Xueding
    Pang, Yin
    Bi, Huichang
    Huang, Lihui
    Zeng, Guixiong
    Liao, Xiaoxing
    Ma, Zhongfu
    Chen, Xiao
    Zhong, Guoping
    Huang, Min
    Zhao, Xianglan
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (10) : 1506 - 1513
  • [23] Development and validation of an HPLC-UV method for the simultaneous quantification of carbamazepine, oxcarbazepine, eslicarbazepine acetate and their main metabolites in human plasma
    Ana Fortuna
    Joana Sousa
    Gilberto Alves
    Amílcar Falcão
    Patrício Soares-da-Silva
    Analytical and Bioanalytical Chemistry, 2010, 397 : 1605 - 1615
  • [24] Development and validation of an HPLC-UV method for the simultaneous quantification of carbamazepine, oxcarbazepine, eslicarbazepine acetate and their main metabolites in human plasma
    Fortuna, Ana
    Sousa, Joana
    Alves, Gilberto
    Falcao, Amilcar
    Soares-da-Silva, Patricio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (04) : 1605 - 1615
  • [25] Development and validation of an enantioselective SFC-MS/MS method for simultaneous separation and quantification of oxcarbazepine and its chiral metabolites in beagle dog plasma
    Yang, Zhichao
    Xu, Xueyu
    Sun, Lingxia
    Zhao, Xue
    Wang, Hao
    Fawcett, John Paul
    Yang, Yan
    Gu, Jingkai
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1020 : 36 - 42
  • [26] Development and validation of an UPLC-ESI-MS/MS method for simultaneous quantification of antineoplastic agents and their metabolites in human plasma after unintentional exposure
    Verscheure, Eline
    Struys, Ilana
    Creta, Matteo
    Poels, Katrien
    Vanoirbeek, Jeroen
    Lenaerts, Liesbeth
    Amant, Frederic
    Ghosh, Manosij
    Godderis, Lode
    ARCHIVES OF TOXICOLOGY, 2025, 99 (01) : 259 - 270
  • [27] Validation of an LC-MS/MS method for the simultaneous quantification of dabigatran, rivaroxaban and apixaban in human plasma
    Baldelli, Sara
    Cattaneo, Dario
    Pignatelli, Pasquale
    Perrone, Valentina
    Pastori, Daniele
    Radice, Sonia
    Violi, Francesco
    Clementi, Emilio
    BIOANALYSIS, 2016, 8 (04) : 275 - 283
  • [28] HPLC-ESI-MS/MS validated method for simultaneous quantification of zopiclone and its metabolites, N-desmethyl zopiclone and zopiclone-N-oxide in human plasma
    Mistri, Hiren N.
    Jangid, Arvind G.
    Pudage, Ashutosh
    Shrivastav, Pranav
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 864 (1-2): : 137 - 148
  • [29] Validation of an LC-MS/MS method for simultaneous quantification of abiraterone, enzalutamide and darolutamide in human plasma
    Buck, Stefan A. J.
    de Bruijn, Peter
    Ghobadi-Moghaddam-Helmantel, Inge M.
    Lam, Mei H.
    de Wit, Ronald
    Koolen, Stijn L. W.
    Mathijssen, Ron H. J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1225
  • [30] Development and validation of an HPLC method, with fluorescence detection, for simultaneous determination of paroxetine and its metabolites in plasma
    Vergi-Athanasiou, Niki
    Atta-Politou, Julia
    Koupparis, Michael
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (9-12) : 1641 - 1655