Diffusion measurements using the nonlinear stimulated echo

被引:17
|
作者
Ardelean, I [1 ]
Kimmich, R [1 ]
机构
[1] Univ Ulm, Sekt Kernresonanzspektroskopie, D-89069 Ulm, Germany
关键词
NMR; diffusion; demagnetizing field; stimulated echo; field gradient;
D O I
10.1006/jmre.1999.1975
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The nonlinear stimulated echo that is generated by a sequence of three radiofrequency pulses, 90 degrees-(T1),-90 degrees-(T2),-45 degrees, in high magnetic fields (or at low temperatures) in the presence of pulsed or steady field gradients can be applied for measurements of the diffusion coefficient. Corresponding test experiments are reported. Steady gradients can be used without knowledge of the relaxation times. Remarkably the attenuation of the nonlinear stimulated echo by diffusion is substantially stronger than in the case of the ordinary stimulated echo. (C) 2000 Academic Press.
引用
收藏
页码:101 / 105
页数:5
相关论文
共 50 条
  • [41] Borehole measurements of adsorbed gas content in coals using stimulated diffusion nuclear magnetic resonance
    O'Neill, T. Keelan
    Birt, Benjamin
    Hopper, Timothy
    INTERNATIONAL JOURNAL OF COAL GEOLOGY, 2021, 247
  • [42] Choice of reference measurements affects quantification of long diffusion time behaviour using stimulated echoes
    Kleinnijenhuis, Michiel
    Mollink, Jeroen
    Lam, Wilfred W.
    Kinchesh, Paul
    Khrapitchev, Alexandre A.
    Smart, Sean C.
    Jbabdi, Saad
    Miller, Karla L.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 952 - 959
  • [43] DIFFUSION IMAGING USING STIMULATED ECHOES
    MERBOLDT, KD
    HANICKE, W
    FRAHM, J
    MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) : 233 - 239
  • [44] GRATING STIMULATED ECHO
    DUBETSKY, B
    BERMAN, PR
    SLEATOR, T
    PHYSICAL REVIEW A, 1992, 46 (05): : R2213 - R2216
  • [45] STIMULATED ECHO IMAGING
    FRAHM, J
    MERBOLDT, KD
    HANICKE, W
    HAASE, A
    JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) : 81 - 93
  • [46] MRI size assessment of cerebral microvasculature using diffusion -time -dependent stimulated -echo acquisition: A feasibility study in rodent
    Lee, D. K.
    Kang, M. S.
    Cho, H.
    NEUROIMAGE, 2020, 215
  • [47] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    Heiland, S
    Dietrich, O
    Sartor, K
    NEURORADIOLOGY, 2001, 43 (06) : 442 - 447
  • [48] Diffusion tensor cardiovascular magnetic resonance with a spiral trajectory: An in vivo comparison of echo planar and spiral stimulated echo sequences
    Gorodezky, Margarita
    Scott, Andrew D.
    Ferreira, Pedro F.
    Nielles-Vallespin, Sonia
    Pennell, Dudley J.
    Firmin, David N.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 648 - 654
  • [49] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    S. Heiland
    O. Dietrich
    K. Sartor
    Neuroradiology, 2001, 43 : 442 - 447
  • [50] ECHO MEASUREMENTS USING INTERGRATED IMPULSE ANSWER
    KUTTRUFF, H
    JUSOFIE, MJ
    ACUSTICA, 1967, 19 (01): : 56 - &