Diffusion measurements using the nonlinear stimulated echo

被引:17
|
作者
Ardelean, I [1 ]
Kimmich, R [1 ]
机构
[1] Univ Ulm, Sekt Kernresonanzspektroskopie, D-89069 Ulm, Germany
关键词
NMR; diffusion; demagnetizing field; stimulated echo; field gradient;
D O I
10.1006/jmre.1999.1975
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The nonlinear stimulated echo that is generated by a sequence of three radiofrequency pulses, 90 degrees-(T1),-90 degrees-(T2),-45 degrees, in high magnetic fields (or at low temperatures) in the presence of pulsed or steady field gradients can be applied for measurements of the diffusion coefficient. Corresponding test experiments are reported. Steady gradients can be used without knowledge of the relaxation times. Remarkably the attenuation of the nonlinear stimulated echo by diffusion is substantially stronger than in the case of the ordinary stimulated echo. (C) 2000 Academic Press.
引用
收藏
页码:101 / 105
页数:5
相关论文
共 50 条
  • [1] Diffusion measurements using the second echo
    Fabich, Hilary T.
    Nandi, Partha
    Thomann, Hans
    Conradi, Mark S.
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2018, 47A (02)
  • [2] The Nonlinear Stimulated Echo
    Department of Physics, Technical University, 3400 Cluj-Napoca, Romania
    不详
    J. Magn. Reson., 2 (506-508):
  • [3] The nonlinear stimulated echo
    Ardelean, I
    Stapf, S
    Demco, DE
    Kimmich, R
    JOURNAL OF MAGNETIC RESONANCE, 1997, 124 (02) : 506 - 508
  • [4] A stimulated-echo method for diffusion measurements in heterogeneous media using pulsed field gradients
    Sorland, GH
    Hafskjold, B
    Herstad, O
    JOURNAL OF MAGNETIC RESONANCE, 1997, 124 (01) : 172 - 176
  • [5] Diffusion measurements with the pulsed gradient nonlinear spin echo method
    Ardelean, I
    Kimmich, R
    JOURNAL OF CHEMICAL PHYSICS, 2000, 112 (12): : 5275 - 5280
  • [6] Accelerated radial diffusion spectrum imaging using a multi-echo stimulated echo diffusion sequence
    Baete, Steven H.
    Boada, Fernando E.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 306 - 316
  • [7] DIFFUSION MEASUREMENTS USING STIMULATED ROTARY ECHOES
    DUPEYRE, R
    DEVOULON, P
    BOURGEOIS, D
    DECORPS, M
    JOURNAL OF MAGNETIC RESONANCE, 1991, 95 (03): : 589 - 596
  • [8] PULSED FIELD GRADIENT STIMULATED ECHO METHODS FOR IMPROVED NMR DIFFUSION MEASUREMENTS IN HETEROGENEOUS SYSTEMS
    COTTS, RM
    HOCH, MJR
    SUN, T
    MARKERT, JT
    JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (02): : 252 - 266
  • [9] ON DOUBLING THE SIGNAL IN LOCALIZED STIMULATED ECHO MEASUREMENTS
    PAYNE, GS
    LEACH, MO
    MAGNETIC RESONANCE IMAGING, 1995, 13 (04) : 629 - 632
  • [10] The nonlinear stimulated echo in the presence of inequivalent spins
    Ardelean, I
    Kimmich, R
    Stapf, S
    Demco, DE
    JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) : 138 - 143