ClearPEM is a rotating, dual planar detector PET system dedicated to breast and axilla imaging that needs data corrections in order to improve quantification and lesion detectability. Since the scanner does not have CT nor transmission sources, we are implementing data corrections that use emission-only data. Also, since in this work we are using an iterative list-mode reconstruction algorithm that projects the data directly through a 3D grid of points, all the corrections are applied in image space. We describe the current implementation and validation of image-based corrections for normalization, scatter, attenuation and randoms. Normalization correction uses sensitivity images generated by backprojecting data from a planar source. Energy-based scatter correction is applied using the Estimation of Trues Method because this method does not require information about attenuating media and takes into account the activity outside the FOV. Attenuation correction is calculated from the segmentation of the breast in the emission images. Randoms correction is performed by subtraction of a smoothed image obtained from the backprojection of the delayed coincidences. The implementation of other corrections is also being pursued in order to obtain fully quantitative images in breast imaging.
引用
收藏
页码:3040 / 3043
页数:4
相关论文
共 50 条
  • [1] Image enhancement in positron emission mammography
    Slavine, Nikolai V.
    Seiler, Stephen
    McColl, Roderick W.
    Lenkinski, Robert E.
    [J]. MEDICAL IMAGING 2017: IMAGE PROCESSING, 2017, 10133
  • [2] Image improvement method for positron emission mammography
    Slavine, Nikolai V.
    Seiler, Stephen J.
    McColl, Roderick W.
    Lenkinski, Robert E.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 : 164 - 173
  • [3] Targeted Image Reconstruction in Positron Emission Mammography
    Picado, G.
    Matela, N.
    Oliveira, N.
    Almeida, P.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5, 2009, 25 : 358 - 361
  • [4] Positron emission tomography data corrections and calibrations
    Levin, CS
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2074 - 2074
  • [5] Positron Emission Mammography Image Interpretation for Reduced Image Count Levels
    MacDonald, Lawrence R.
    Hippe, Daniel S.
    Bender, Leila C.
    Cotter, Elizabeth W.
    Voria, Pooja R.
    Hallam, Paula S.
    Wang, Carolyn L.
    Haseley, David R.
    Kelly, Mary M.
    Parikh, Jay R.
    Beatty, J. David
    Rogers, James V.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (03) : 348 - 354
  • [6] An Image Quality Assurance Phantom for Positron Emission Mammography (PEM)
    Luo, W.
    Disher, N.
    Lu, X.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Image-based atmospheric corrections revisited and improved
    Chavez, PS
    [J]. PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1996, 62 (09): : 1025 - 1036
  • [8] Data acquisition electronics for positron emission mammography (PEM) detectors
    Martínez, JD
    Sebastiá, A
    Cerdá, J
    Esteve, R
    Mora, FJ
    Toledo, JF
    Benlloch, JM
    Giménez, N
    Giménez, M
    Lerche, CW
    Pavón, N
    Sánchez, F
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2): : 335 - 338
  • [9] Positron emission mammography (PEM)
    Garcia-Gomez, Jaime I.
    Villasenor-Navarro, Yolanda
    [J]. GACETA MEXICANA DE ONCOLOGIA, 2012, 11 (04): : 281 - 287
  • [10] Applications for positron emission mammography
    Weinberg, Irving N.
    [J]. PHYSICA MEDICA, 2006, 21 : 132 - 137