Study on energy saving possibility of digital variable multiple air conditioning system in three office buildings in Shanghai

被引:20
|
作者
Zhang, Dongliang [1 ]
Zhang, Xu [2 ]
Cai, Ning [1 ]
机构
[1] Nanjing Inst Technol, Coll Energy & Power Engn, Nanjing 211167, Jiangsu, Peoples R China
[2] Tongji Univ, Coll Mech Engn, Shanghai 200092, Peoples R China
关键词
Multi-connected air conditioning system; Operational performance; Energy saving possibility;
D O I
10.1016/j.enbuild.2014.01.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this paper was to study energy saving possibility of DVM air conditioning system compared to all-air system with constant air volume and primary air fan-coil system. Three office buildings are selected to study the impact of outdoor air temperature and air-conditioning load on energy consumption of the above three systems. eQUEST was used to simulate the annual building performance. The simulation results indicate that energy saving potentiality of DVM air conditioning system is significant under part load condition because of its indoor unit independently controlled characteristic and good regulating characteristics; for office building with boundary condition in standard GB 50189-2005, energy saving potentiality of DVM air conditioning system is significant when building area is less than 20,000m(2), or primary air fan-coil system with two sets of water source screw chiller is more available. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 50 条
  • [21] Experimental study of performance of digital variable multiple air conditioning system under part load conditions
    Zhang, Dongliang
    Zhang, Xu
    Liu, Jun
    ENERGY AND BUILDINGS, 2011, 43 (06) : 1175 - 1178
  • [22] Application of Rheology for Energy Saving Air Conditioning System
    Usui, Hiromoto
    Saeko, Takashi
    NIHON REOROJI GAKKAISHI, 2010, 38 (03) : 141 - 147
  • [23] Comparative study of air-conditioning energy use of four office buildings in China and USA
    Zhou, Xin
    Yan, Da
    An, Jingjing
    Hong, Tianzhen
    Shi, Xing
    Jin, Xing
    ENERGY AND BUILDINGS, 2018, 169 : 344 - 352
  • [24] Energy saving of variable chilled water temperature in air conditioning system based on thermal comfort
    Chen Y.
    Liang C.
    Zhang J.
    Zhang X.
    Liang, Caihua (caihualiang@163.com), 1600, Southeast University (50): : 875 - 881
  • [25] Energy-saving studies of variable-frequency air conditioning fans for marine air conditioning
    Han Houde
    Ji Jun
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 871 - +
  • [26] BIOLOGICAL CONTAMINATION IN OFFICE BUILDINGS RELATED TO VENTILATION/AIR CONDITIONING SYSTEM
    Brodka, Karolina
    Sowiak, Malgorzata
    Kozajda, Anna
    Cyprowski, Marcin
    Szadkowska-Stanczyk, Irena
    MEDYCYNA PRACY, 2012, 63 (03) : 303 - 315
  • [27] Design and adaptability of photovoltaic air conditioning system based on office buildings
    Chen, Yingya
    Liu, Yanfeng
    Liu, Jingrui
    Luo, Xi
    Wang, Dengjia
    Wang, Yingying
    Liu, Jiaping
    SOLAR ENERGY, 2020, 202 : 17 - 24
  • [28] The study of energy-saving strategy for direct expansion air conditioning system
    Chiou, C. B.
    Chiou, C. H.
    Chu, C. M.
    Lin, S. L.
    ENERGY AND BUILDINGS, 2008, 40 (09) : 1660 - 1665
  • [29] Study on pressure control and energy saving of cleanroom in purification air conditioning system
    Liu, Jiahui
    Zhang, Lun
    Yang, Jinsong
    Chen, Yao
    Zhang, Xiaosong
    ENERGY AND BUILDINGS, 2021, 253
  • [30] An Energy Efficient Air Conditioning System using Displacement Ventilation and Chilled Ceiling for Modern Office Buildings
    Parameshwaran, R.
    Karunakaran, R.
    Muthumariappan, S.
    Bipasha, S.
    INTERNATIONAL JOURNAL OF VENTILATION, 2010, 9 (01) : 25 - 44