A new method using flow cytometry to measure the effects of drugs on gastric emptying and gastrointestinal transit in mice

被引:1
|
作者
Inada, T [1 ]
Asai, T [1 ]
Yamada, M [1 ]
Shingu, K [1 ]
机构
[1] Kansai Med Univ Hosp, Dept Anesthesiol, Moriguchi, Osaka 5708507, Japan
来源
ARZNEIMITTELFORSCHUNG-DRUG RESEARCH | 2004年 / 54卷 / 09期
关键词
CAS; 52-26-6; 113775-47-6; dexmedetomidine; flow cytometry; gastric emptying; effect of drugs; gastrointestinal transit; morphine;
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The use of radiolabelled markers is considered to be a gold standard for assessing gastric emptying and gastrointestinal transit in mice and rats, but their use has increasingly been restricted due to health concern. Therefore, a new method using fluorescent polystyrene microbeads and flow cytometry was devised. Saline containing fluorescent markers (together with non-fluorescent microbeads) was infused into the stomach of each mouse and gastric emptying and gastrointestinal transit were calculated by measuring the quantity of the fluorescent microbeads in the gastrointestinal tract using flow cytometer. The effects of saline (as a control), morphine (CAS 52-26-6) and dexmedetomidine (CAS 113775-47-6) were tested. Both gastric emptying and gastrointestinal transit measured with this method (after i.p. injection of saline) were similar to those reported previously using the conventional radiolabelled methods. Morphine significantly inhibited both gastric emptying and gastrointestinal transit in a dose-dependent manner. Dexmedetomidine did not significantly inhibit gastric emptying but inhibited gastrointestinal transit. These results were also similar to those obtained using the conventional radiolabelled method. The method using fluorescent microbeads and flow cytometry may be a reliable alternative to the methods using radioisotope for studying the effects of drugs on gastric emptying and gastrointestinal transit.
引用
收藏
页码:557 / 562
页数:6
相关论文
共 50 条
  • [41] A NEW METHOD FOR CHARACTERIZATION AND IDENTIFICATION OF GASTROINTESTINAL TUMOR-CELLS BY FLOW-CYTOMETRY DETERMINATION OF CEA AND EMA
    WIRSCHING, R
    RUSSMANN, L
    VALET, G
    KOLLER, J
    ORMEROD, M
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1983, 361 : 931 - 931
  • [42] EVALUATION OF THE GASTRIC ABSORPTION AND EMPTYING OF DRUGS UNDER VARIOUS PH CONDITIONS USING A SIMPLE INTUBATION METHOD - APPLICATION TO DICLOFENAC
    VIDON, N
    PFEIFFER, A
    GODBILLON, J
    RONGIER, M
    GAURON, S
    HIRTZ, J
    BERNIER, JJ
    DUBOIS, JP
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1989, 28 (01) : 121 - 124
  • [43] A new analytical method for the detection of anti-tumor promoters using flow cytometry
    Zaizen, Y
    Tokuda, H
    Ueda, H
    Nishino, H
    Ishikawa, C
    Takeshita, M
    ANTICANCER RESEARCH, 1999, 19 (6B) : 5207 - 5209
  • [44] Optimization of FDA-PI method using flow cytometry to measure metabolic activity of the cyanobacteria, Microcystis aeruginosa
    Xiao Xi
    Han Zhi-ying
    Chen Ying-xu
    Liang Xin-qiang
    Li Hua
    Qian Yi-chao
    PHYSICS AND CHEMISTRY OF THE EARTH, 2011, 36 (9-11) : 424 - 429
  • [45] THE MEASUREMENT OF GASTRIC TRANSIT-TIME IN OBESE SUBJECTS USING NA-24 AND THE EFFECTS OF ENERGY CONTENT AND GUAR GUM ON GASTRIC-EMPTYING AND SATIETY
    WILMSHURST, P
    CRAWLEY, JCW
    BRITISH JOURNAL OF NUTRITION, 1980, 44 (01) : 1 - 6
  • [46] A non-invasive method for measurement of gastric emptying in mice: effects of altering fat content and CCK A receptor blockade
    Whited, KL
    Hornof, WJ
    Garcia, T
    Bohan, DC
    Larson, RF
    Raybould, HE
    NEUROGASTROENTEROLOGY AND MOTILITY, 2004, 16 (04): : 421 - 427
  • [47] EFFECTS OF MEALS ON GASTRIC-EMPTYING AND SMALL INTESTINAL TRANSIT TIMES OF A SUSPENSION IN THE BEAGLE DOG ASSESSED USING ACETAMINOPHEN AND SALICYLAZOSULFAPYRIDINE AS MARKERS
    MIZUTA, H
    KAWAZOE, Y
    HAGA, K
    OGAWA, K
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1990, 38 (08) : 2224 - 2227
  • [48] INTERGROUP AGGRESSION IN MICE - NEW METHOD FOR TESTING EFFECTS OF CENTRALLY ACTIVE DRUGS
    ZWIRNER, PP
    PORSOLT, RD
    LOEW, DM
    PSYCHOPHARMACOLOGIA, 1975, 45 (02): : 133 - 138
  • [49] Monitoring of new therapeutical anti-GPIIb/IIa using a quantitative flow cytometry method
    Besson, I
    Hezard, N
    Metz, D
    Daliphard, S
    Maes, D
    Simon, G
    Potron, G
    THROMBOSIS AND HAEMOSTASIS, 1997, : OC27 - OC27
  • [50] A NEW METHOD FOR EVALUATING EXPERIMENTAL CRYPTOSPORIDIAL PARASITE LOADS USING IMMUNOFLUORESCENT FLOW-CYTOMETRY
    ARROWOOD, MJ
    HURD, MR
    MEAD, JR
    JOURNAL OF PARASITOLOGY, 1995, 81 (03) : 404 - 409