An estimate of hopper outlet size and slope for mass flow from the flowability index

被引:5
|
作者
Endo, Y
Alonso, M
机构
[1] Sumitomo Chem Co Ltd, Proc & Prod Technol Ctr, Konohana Ku, Osaka 5548558, Japan
[2] CSIC, Natl Ctr Met Res, Madrid, Spain
来源
关键词
hopper design; mass flow; flowability; powder bed shear test; Jenike yield locus; Carr's method;
D O I
10.1205/026387602760312827
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The opening size of the discharge outlet and the slope of a conical hopper call be determined using the well-known theoretical method of Jenike. This method enables designing the hopper almost so precisely as to permit mass flow powder discharge (without stagnant zone). On the other hand, a flowability index is Customarily used as a measure of the ease of powder flow. From a practical point of view, it should be desirable to predict whether a given powder will form arches or bridges that will prevent its mass flow discharge from the hopper. In order to obtain such a predictive tool, we have studied the relationships, for 90 powders, between (1) the mass flow hopper outlet size and flowability index, and (2) the mass flow hopper slope and flowability index. In both cases, there is a considerable scattering of experimental data, but limiting functional relations have been obtained that allow practical determination of safety values for mass flow hopper outlet size and slope as a function of the flowability index.