An estimate of hopper outlet size and slope for mass flow from the flowability index

被引:5
|
作者
Endo, Y
Alonso, M
机构
[1] Sumitomo Chem Co Ltd, Proc & Prod Technol Ctr, Konohana Ku, Osaka 5548558, Japan
[2] CSIC, Natl Ctr Met Res, Madrid, Spain
来源
关键词
hopper design; mass flow; flowability; powder bed shear test; Jenike yield locus; Carr's method;
D O I
10.1205/026387602760312827
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The opening size of the discharge outlet and the slope of a conical hopper call be determined using the well-known theoretical method of Jenike. This method enables designing the hopper almost so precisely as to permit mass flow powder discharge (without stagnant zone). On the other hand, a flowability index is Customarily used as a measure of the ease of powder flow. From a practical point of view, it should be desirable to predict whether a given powder will form arches or bridges that will prevent its mass flow discharge from the hopper. In order to obtain such a predictive tool, we have studied the relationships, for 90 powders, between (1) the mass flow hopper outlet size and flowability index, and (2) the mass flow hopper slope and flowability index. In both cases, there is a considerable scattering of experimental data, but limiting functional relations have been obtained that allow practical determination of safety values for mass flow hopper outlet size and slope as a function of the flowability index.
引用
收藏
页码:625 / 630
页数:6
相关论文
共 46 条
  • [1] EFFECT OF EFFLUX TUBE SIZE ON GRAVITY FLOW OF POWDERS FROM A HOPPER
    YAMASHIRO, M
    KUNO, H
    KAGAKU KOGAKU RONBUNSHU, 1989, 15 (04) : 875 - 877
  • [2] CAN THE SIZE-SPECIFIC DOSE ESTIMATE BE DERIVED FROM THE BODY MASS INDEX? A FEASIBILITY STUDY
    Steiniger, Beatrice
    Klippel, Chris
    Teichgraeber, Ulf
    Reichenbach, Juergen R.
    Fiebich, Martin
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (06) : 325 - 333
  • [3] EFFECT OF PARTICLE-SIZE ON THE GRAVITY FLOW OF POWDERS FROM A HOPPER WITH EFFLUX TUBE
    YAMASHIRO, M
    KAGAKU KOGAKU RONBUNSHU, 1988, 14 (01) : 46 - 53
  • [4] Ejection times from a conical mass flow hopper - Coulomb and conical model differences
    Fullard, Luke
    Davies, Clive
    APPLIED MATHEMATICAL MODELLING, 2016, 40 (02) : 1494 - 1505
  • [5] Simulation of mass flow rate of particles discharged from hopper by Particle Element Method
    Kano, J
    Saito, F
    Shimosaka, A
    Hidaka, J
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1998, 31 (06) : 936 - 940
  • [6] THE RATE OF DISCHARGE OF COARSE GRANULAR MATERIAL FROM A WEDGE-SHAPED MASS-FLOW HOPPER
    KAZA, KR
    JACKSON, R
    POWDER TECHNOLOGY, 1982, 33 (02) : 223 - 237
  • [7] A Brief Investigation into Ejection Times from a Conical Mass Flow Hopper - Coulomb and Conical Model Difference
    Fullard, L. A.
    Davies, C. E.
    POWDERS AND GRAINS 2013, 2013, 1542 : 1254 - 1257
  • [8] Gland size estimation and body mass index improve salivary flow rate assessment
    Dawes, C.
    ARCHIVES OF ORAL BIOLOGY, 2007, 52 (05) : 409 - 410
  • [9] Estimate Height Weight and Body Mass Index From Face Image Using Machine Learning
    Kumar, Ashwani
    Deeksha, Kondam
    Pooja, G. Sai
    Reddy, T. Tarun
    Reddy, Tera Akhil
    2022 5TH INTERNATIONAL CONFERENCE ON MULTIMEDIA, SIGNAL PROCESSING AND COMMUNICATION TECHNOLOGIES (IMPACT), 2022,
  • [10] Estimate of prevalent ischemic stroke from triglyceride glucose-body mass index in the general population
    Zhi Du
    Liying Xing
    Min Lin
    Yingxian Sun
    BMC Cardiovascular Disorders, 20