Improved in Vitro Blood Compatibility of Polycaprolactone Nanowire Surfaces

被引:39
|
作者
Leszczak, Victoria [1 ]
Popat, Ketul C. [1 ,2 ]
机构
[1] Colorado State Univ, Dept Mech Engn, Ft Collins, CO 80523 USA
[2] Colorado State Univ, Sch Biomed Engn, Ft Collins, CO 80523 USA
基金
美国国家卫生研究院;
关键词
polycaprolactone nanowire surfaces; hemocompatibility; platelet activation; leukocyte adhesion; hemolysis; CELL FUNCTIONALITY; PROTEIN ADSORPTION; VASCULAR GRAFTS; COLLAGEN; HEMOCOMPATIBILITY; POLYMERS; BIOMATERIALS; COAGULATION; SCAFFOLD; OSTEOBLASTS;
D O I
10.1021/am503508r
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
There are a multitude of polymeric materials currently utilized to prepare a variety of blood-contacting implantable medical devices. These devices include tissue grafts, coronary artery and vascular stents, and orthopedic implants. The thrombogenic nature of such materials can cause serious complications in patients, and ultimately lead to functional failure. To date, there is no truly hemocompatible biomaterial surface. Nanostructured surfaces improve cellular interactions but there is a limited amount of information regarding their blood compatibility. In this study, the in vitro blood compatibility of four different surfaces (control, PCL; nanowire, NW; collagen immobilized control, cPCL; collagen immobilized nanowire, cNW) were investigated for their use as interfaces for blood-contacting implants. The results presented here indicate enhanced in vitro blood compatibility of nanowire surfaces compared control surfaces. Although there were no significant differences in leukocyte adhesion, there was a decrease in platelet adhesion on NW surfaces. Scanning electron microscopy images showed a decrease in platelet/leukocyte complexes on cNW surfaces and no apparent complexes were formed on NW surfaces compared to PCL and cPCL surfaces. The increase in these complexes likely contributed to a higher expression of specific markers for platelet and leukocyte activation on PCL and cPCL surfaces. No significant differences were found in contact and complement activation on any surface. Further, thrombin antithrombin complexes were significantly reduced on NW surfaces. A significant increase in hemolysis and fibrinogen adsorption was identified on PCL surfaces likely caused by its hydrophobic surface. This work shows the improved blood-compatibility of nanostructured surfaces, identifying this specific nanoarchitecture as a potential interface for promoting the long-term success of blood-contacting biomaterials.
引用
收藏
页码:15913 / 15924
页数:12
相关论文
共 50 条
  • [22] In vitro compatibility testing of canine and rabbit blood
    Cutler, Simone M.
    Richardson, Jenna
    Eatwell, Kevin
    Llewellyn, Efa A.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2021, 31 (06) : 742 - 748
  • [23] Blood compatibility of polymers: in vitro and in vivo tests
    Lemm, W.
    Unger, V.
    Buecherl, E.S.
    Medical and Biological Engineering and Computing, 1980, 18 (04): : 521 - 526
  • [24] POLYMER SURFACES COATED WITH HYDROGEL TO IMPROVE BLOOD COMPATIBILITY
    Butruk, B.
    Ciach, T.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 663 - 663
  • [25] A SURFACE ENERGETIC CRITERION OF BLOOD COMPATIBILITY OF FOREIGN SURFACES
    RUCKENSTEIN, E
    GOURISANKAR, SV
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1984, 101 (02) : 436 - 451
  • [26] Relationship between blood compatibility and nonthrombogenic polymer surfaces
    Uchida, K
    Waki, M
    Sakai, K
    Nojiri, C
    Kido, T
    Sugiyama, T
    Ishihara, K
    Nakabayashi, N
    KAGAKU KOGAKU RONBUNSHU, 1998, 24 (02) : 217 - 221
  • [27] BLOOD COMPATIBILITY OF ALBUMIN-HEPARIN TREATED SURFACES
    HENNINK, WE
    DOST, L
    KIM, SW
    FEIJEN, J
    ARTIFICIAL ORGANS, 1984, 8 (01) : 127 - 128
  • [28] CURRENT TECHNIQUES TO IMPROVE THE BLOOD COMPATIBILITY OF BIOMATERIAL SURFACES
    ENGBERS, GH
    FEIJEN, J
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (04): : 199 - 215
  • [29] Improved blood compatibility of DLC coated polymeric material
    Alanazi, A
    Nojiri, C
    Noguchi, T
    Kido, T
    Komatsu, Y
    Hirakuri, K
    Funakubo, A
    Sakai, K
    Fukui, Y
    ASAIO JOURNAL, 2000, 46 (04) : 440 - 443
  • [30] CHEMICAL MODIFICATION OF CELLULOSIC MEMBRANES FOR IMPROVED BLOOD COMPATIBILITY
    RINTELEN, T
    VIENKEN, J
    BAURMEISTER, U
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 198 : 144 - PMSE