A biosensor for Escherichia coli based on a potentiometric alternating biosensing (PAB) transducer

被引:27
|
作者
Ercole, C [1 ]
Del Gallo, M
Pantalone, M
Santucci, S
Mosiello, L
Laconi, C
Lepidi, A
机构
[1] Univ Aquila, Dept Basic & Appl Biol, I-67010 Coppito, Italy
[2] Univ Aquila, Dept Phys, I-67010 Coppito, Italy
[3] Univ Aquila, Unita INFM, I-67010 Coppito, Italy
[4] ENEA Casaccia, I-00060 Rome, Italy
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2002年 / 83卷 / 1-3期
关键词
biosensor; E; coli; water pollution; light addressable potentiometric sensor (LAPS); immunoassay;
D O I
10.1016/S0925-4005(01)01027-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present paper, we describe a biosensor for the detection of bacterial contamination in drinking water based on an immunoassay test. The biological component was made by a rabbit polyclonal antibody obtained utilising an environmental strain of Escherichia coli, DH5alpha. This strain, showed a capsular protein pattern typical of this species. Cells present in water samples were detected by a complete potentiometric alternating biosensor (PAB). The PAB system consists of a measuring chamber, acquisition and driving electronics and the appropriate software: the apparatus is computer controlled in order to obtain on-line acquisitions and recording of data. The transducer principle is based on a light addressable potentiometric sensor (LAPS) technology which, in our case, reveals the production of NH3 by a urease-E. coli antibody conjugate. The proposed system appears to be very sensitive and fast, in comparison with conventional methods: concentrations of 10 cells per ml were detected in an assay time of ca. 1.5 h. No signals were detected from other potential water polluting bacteria, such as Pseudomonas marina and Sphaerotilus natans and also from bacteria such as Klebsiella oxytoca phyletically related to E. coli. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:48 / 52
页数:5
相关论文
共 50 条
  • [21] Chloride sensor based on a new potentiometric transducer
    Dybko, A
    Wróblewski, W
    Brzózka, Z
    OPTOELECTRONIC AND ELECTRONIC SENSORS V, 2002, : 69 - 73
  • [22] A cantilever biosensor based on a gap method for detecting Escherichia coli in real time
    Leahy, Stephane
    Lai, Yongjun
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 246 : 1011 - 1016
  • [23] Whole cell based microcontact imprinted capacitive biosensor for the detection of Escherichia coli
    Idil, Neslihan
    Hedstrom, Martin
    Denizli, Adil
    Mattiasson, Bo
    BIOSENSORS & BIOELECTRONICS, 2017, 87 : 807 - 815
  • [24] Application of Aptamer-Based Biosensor for Rapid Detection of Pathogenic Escherichia coli
    Zhao, Yu-Wen
    Wang, Hai-Xia
    Jia, Guang-Cheng
    Li, Zheng
    SENSORS, 2018, 18 (08)
  • [25] Engineering and modeling of a modular, motility-based biosensor system in Escherichia coli
    Ravichandar, Jayamary Divya
    Bower, Adam
    Julius, Agung
    Collins, Cynthia
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [26] Research progress in fluorescent biosensor technology for detecting Escherichia coli based on PCR
    Guo, Wenjin
    Li, Qian
    Yang, Xinran
    Xu, Pengbo
    Cai, Gaozhe
    Cui, Chuanjin
    SENSOR REVIEW, 2024, 44 (06) : 682 - 695
  • [27] Research on Photonic Crystal-Based Biosensor for Detection of Escherichia coli Colony
    Hao, Jiong-Ju
    Xie, Xun
    Gu, Ke-Da
    Du, Wei-Chen
    Liu, Yu-Jie
    Yang, Hong-Wei
    PLASMONICS, 2019, 14 (06) : 1919 - 1928
  • [28] Development of an Escherichia coli-based electrochemical biosensor for mycotoxin toxicity detection
    Chen, Yafei
    Yang, Yajie
    Wang, Yu
    Peng, Ye
    Nie, Jinmei
    Gao, Guanyue
    Zhi, Jinfang
    BIOELECTROCHEMISTRY, 2020, 133
  • [29] A POTENTIOMETRIC MICROBIAL SENSOR BASED ON IMMOBILIZED ESCHERICHIA-COLI FOR GLUTAMIC-ACID
    HIKUMA, M
    OBANA, H
    YASUDA, T
    KARUBE, I
    SUZUKI, S
    ANALYTICA CHIMICA ACTA, 1980, 116 (01) : 61 - 67
  • [30] Porous silicon based potentiometric triglyceride biosensor
    Reddy, RRK
    Chadha, A
    Bhattacharya, E
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (4-5): : 313 - 317