Plasticizer Interaction With the Heart Chemicals Used in Plastic Medical Devices Can Interfere With Cardiac Electrophysiology

被引:34
|
作者
Jaimes, Rafael, III [1 ,2 ]
McCullough, Damon [1 ]
Siegel, Bryan [2 ]
Swift, Luther [1 ,2 ]
McInerney, Daniel [1 ]
Hiebert, James [1 ]
Perez-Alday, Erick A. [6 ]
Trenor, Beatriz [5 ]
Sheng, Jiansong [4 ]
Saiz, Javier
Tereshchenko, Larisa G. [2 ,6 ]
Posnack, Nikki Gillum [1 ,3 ]
机构
[1] Childrens Natl Hlth Syst, Sheikh Zayed Inst Pediat Surg Innovat, Washington, DC USA
[2] Childrens Natl Hlth Syst, Childrens Natl Heart Inst, Washington, DC USA
[3] George Washington Univ, Sch Med & Hlth Sci, Dept Pediat & Pharmacol & Physiol, Washington, DC 20052 USA
[4] CiPA Lab LLC, Rockville, MD USA
[5] Ci2B Univ Politecn Valencia, Valencia, Spain
[6] Oregon Hlth & Sci Univ, Knight Cardiovasc Inst, Portland, OR 97201 USA
来源
基金
美国国家卫生研究院;
关键词
action potentials; electrophysiology; heart; plasticizer; plastics; DI-2-ETHYLHEXYL PHTHALATE DEHP; BEAT RATE VARIABILITY; DI(2-ETHYLHEXYL) PHTHALATE; DI-(2-ETHYLHEXYL) PHTHALATE; NEWBORN-INFANTS; BISPHENOL-A; MONO-(2-ETHYLHEXYL) PHTHALATE; MONO(2-ETHYLHEXYL) PHTHALATE; ENDOCRINE DISRUPTORS; FREQUENCY CONTENT;
D O I
10.1161/CIRCEP.119.007294
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Phthalates are used as plasticizers in the manufacturing of flexible, plastic medical products. Patients can be subjected to high phthalate exposure through contact with plastic medical devices. We aimed to investigate the cardiac safety and biocompatibility of mono-2-ethylhexyl phthalate (MEHP), a phthalate with documented exposure in intensive care patients. Methods: Optical mapping of transmembrane voltage and pacing studies were performed on isolated, Langendorff-perfused rat hearts to assess cardiac electrophysiology after MEHP exposure compared with controls. MEHP dose was chosen based on reported blood concentrations after an exchange transfusion procedure. Results: Thirty-minute exposure to MEHP increased the atrioventricular node (147 versus 107 ms) and ventricular (117 versus 77.5 ms) effective refractory periods, compared with controls. Optical mapping revealed prolonged action potential duration at slower pacing cycle lengths, akin to reverse use dependence. The plateau phase of the action potential duration restitution curve steepened and became monophasic in MEHP-exposed hearts (0.18 versus 0.06 slope). Action potential duration lengthening occurred during late-phase repolarization resulting in triangulation (70.3 versus 56.6 ms). MEHP exposure also slowed epicardial conduction velocity (35 versus 60 cm/s), which may be partly explained by inhibition of Na(v)1.5 (874 and 231 mu mol/L half-maximal inhibitory concentration, fast and late sodium current). Conclusions: This study highlights the impact of acute MEHP exposure, using a clinically relevant dose, on cardiac electrophysiology in the intact heart. Heightened clinical exposure to plasticized medical products may have cardiac safety implications-given that action potential triangulation and electrical restitution modifications are a risk factor for early after depolarizations and cardiac arrhythmias.
引用
收藏
页数:13
相关论文
共 37 条
  • [21] Medical devices used in interventional neuroradiology: can we reach a clinical consensus to rationalize the number of references purchased in a French hospital group?
    Beaussier, H.
    Fare, S.
    Junot, H.
    Degrassat-Theas, A.
    Naud, C.
    Faure, P.
    Sinegre, M.
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACY, 2012, 34 (01) : 162 - 162
  • [22] Can troponin-I be used as an independent predictor of cardiac dysfunction after supraventricular tachycardia in children with structurally normal heart?
    Simovic, Aleksandra M.
    Tanaskovic-Nestorovic, Jelena M.
    Knezevic, Sanja M.
    Vuletic, Biljana P.
    Stojkovic, Andjelka K.
    Jeremic, Dejan M.
    Milan, Jovanovic
    Vulovic, Maja
    VOJNOSANITETSKI PREGLED, 2019, 76 (01) : 76 - 80
  • [23] Use of cardiac allografts with mild and moderate left ventricular hypertrophy can be safely used in heart transplantation to expand the donor pool
    Goland, Sorel
    Czer, Lawrence S. C.
    Kass, Robert M.
    Siegel, Robert J.
    Mirocha, James
    De Robertis, Michele A.
    Lee, Jason
    Raissi, Sharo
    Cheng, Wen
    Fontana, Gregory
    Trento, Alfredo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (12) : 1214 - 1220
  • [24] Can dilution methods be used to assess cardiac performance in patients with complex congenital heart disease? Cardiac output and shunt calculation following a fenestrated Fontan operation
    Harmon, William
    Dwyer-Matzky, Keely
    Schulenberg, Adam
    Rubenstein, Jeffrey
    CRITICAL CARE MEDICINE, 2007, 35 (12) : A287 - A287
  • [25] Fluid-Structure Interaction Simulation of Cardiac Leads in the Heart: Developing a Computational Model for Use in Medical Device Design
    Runesha, Hakizumwami Birali
    Tanasoiu, Bogdan Florin
    Subashki, Georgi
    Erdman, Arthur G.
    Keefe, Daniel F.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (03):
  • [26] Methicillin-resistant Staphylococcus aureus spreading through medical devices used in nursing care: what can we learn from Portugal?
    Costa, P.
    Graveto, J.
    Santos, C.
    Fernandes, E.
    Albano, H.
    Osorio, N.
    Alarico, S.
    Oliveira, V.
    Ferreira, S.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2018, 73 : 292 - 293
  • [27] A COLLABORATIVE APPROACH TO REMOTE HOME MONITORING OF CARDIAC IMPLANTABLE ELECTRONIC DEVICES WITH HEART FAILURE DIAGNOSTICS IS USED TO DETECT SIGNS OF HEART FAILURE EXACERBATION RELATED TO A DECREASE IN BIVENTRICULAR PACING
    Miller, Alanna
    Friedman, Mary
    Leotta, Kimberly
    Shanks, Margaret C.
    Mathelier, Hansie Marie
    D'Souza, Benjamin Anthony
    Mendelson, Todd
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 2974 - 2974
  • [28] CircSLC8A1 and circNFIX can be used as auxiliary diagnostic markers for sudden cardiac death caused by acute ischemic heart disease
    Meihui Tian
    Jiajia Xue
    Cuiyun Dai
    Enzhu Jiang
    Baoli Zhu
    Hao Pang
    Scientific Reports, 11
  • [29] Non-invasive External Counter Pulsation (EECP) Can Even Be Used in theTreatment of Patients with Severely Depressed Cardiac Function and Heart Failure
    Avci, Gunsel
    Ozinci, Ayse Piskin
    Mollaahmet, Sefika
    Sinanoglu, Suna
    Avci, Cenk
    CARDIOVASCULAR THERAPEUTICS, 2012, 30 : 32 - 32
  • [30] CircSLC8A1 and circNFIX can be used as auxiliary diagnostic markers for sudden cardiac death caused by acute ischemic heart disease
    Tian, Meihui
    Xue, Jiajia
    Dai, Cuiyun
    Jiang, Enzhu
    Zhu, Baoli
    Pang, Hao
    SCIENTIFIC REPORTS, 2021, 11 (01)