Plasticizer Interaction With the Heart Chemicals Used in Plastic Medical Devices Can Interfere With Cardiac Electrophysiology

被引:34
|
作者
Jaimes, Rafael, III [1 ,2 ]
McCullough, Damon [1 ]
Siegel, Bryan [2 ]
Swift, Luther [1 ,2 ]
McInerney, Daniel [1 ]
Hiebert, James [1 ]
Perez-Alday, Erick A. [6 ]
Trenor, Beatriz [5 ]
Sheng, Jiansong [4 ]
Saiz, Javier
Tereshchenko, Larisa G. [2 ,6 ]
Posnack, Nikki Gillum [1 ,3 ]
机构
[1] Childrens Natl Hlth Syst, Sheikh Zayed Inst Pediat Surg Innovat, Washington, DC USA
[2] Childrens Natl Hlth Syst, Childrens Natl Heart Inst, Washington, DC USA
[3] George Washington Univ, Sch Med & Hlth Sci, Dept Pediat & Pharmacol & Physiol, Washington, DC 20052 USA
[4] CiPA Lab LLC, Rockville, MD USA
[5] Ci2B Univ Politecn Valencia, Valencia, Spain
[6] Oregon Hlth & Sci Univ, Knight Cardiovasc Inst, Portland, OR 97201 USA
来源
基金
美国国家卫生研究院;
关键词
action potentials; electrophysiology; heart; plasticizer; plastics; DI-2-ETHYLHEXYL PHTHALATE DEHP; BEAT RATE VARIABILITY; DI(2-ETHYLHEXYL) PHTHALATE; DI-(2-ETHYLHEXYL) PHTHALATE; NEWBORN-INFANTS; BISPHENOL-A; MONO-(2-ETHYLHEXYL) PHTHALATE; MONO(2-ETHYLHEXYL) PHTHALATE; ENDOCRINE DISRUPTORS; FREQUENCY CONTENT;
D O I
10.1161/CIRCEP.119.007294
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Phthalates are used as plasticizers in the manufacturing of flexible, plastic medical products. Patients can be subjected to high phthalate exposure through contact with plastic medical devices. We aimed to investigate the cardiac safety and biocompatibility of mono-2-ethylhexyl phthalate (MEHP), a phthalate with documented exposure in intensive care patients. Methods: Optical mapping of transmembrane voltage and pacing studies were performed on isolated, Langendorff-perfused rat hearts to assess cardiac electrophysiology after MEHP exposure compared with controls. MEHP dose was chosen based on reported blood concentrations after an exchange transfusion procedure. Results: Thirty-minute exposure to MEHP increased the atrioventricular node (147 versus 107 ms) and ventricular (117 versus 77.5 ms) effective refractory periods, compared with controls. Optical mapping revealed prolonged action potential duration at slower pacing cycle lengths, akin to reverse use dependence. The plateau phase of the action potential duration restitution curve steepened and became monophasic in MEHP-exposed hearts (0.18 versus 0.06 slope). Action potential duration lengthening occurred during late-phase repolarization resulting in triangulation (70.3 versus 56.6 ms). MEHP exposure also slowed epicardial conduction velocity (35 versus 60 cm/s), which may be partly explained by inhibition of Na(v)1.5 (874 and 231 mu mol/L half-maximal inhibitory concentration, fast and late sodium current). Conclusions: This study highlights the impact of acute MEHP exposure, using a clinically relevant dose, on cardiac electrophysiology in the intact heart. Heightened clinical exposure to plasticized medical products may have cardiac safety implications-given that action potential triangulation and electrical restitution modifications are a risk factor for early after depolarizations and cardiac arrhythmias.
引用
收藏
页数:13
相关论文
共 37 条
  • [1] Plasticizer Interaction With the Heart: Chemicals Used in Plastic Medical Devices Can Interfere With Cardiac Electrophysiology
    Jaimes, Rafael
    McCullough, Damon
    Siegel, Bryan
    Swift, Luther
    McInerney, Daniel
    Hiebert, James
    Sheng Jiansong
    Posnack, Nikki G.
    CIRCULATION RESEARCH, 2019, 125
  • [2] Collodion Remover Can Degrade Plastic-Containing Medical Devices Commonly Used in the Intensive Care Unit
    Fitzgerald M.P.
    Donnelly M.
    Vala L.
    Allen-Napoli L.
    Abend N.S.
    Neurodiagnostic Journal, 2019, 59 (03) : 163 - 168
  • [3] CAN PLASTIC SEMICONDUCTOR-DEVICES AND MICROCIRCUITS BE USED IN MILITARY EQUIPMENT
    REICH, B
    HAKIM, EB
    PROCEEDINGS ANNUAL RELIABILITY AND MAINTAINABILITY SYMPOSIUM, 1974, 7 (02): : 396 - 402
  • [4] Can Implantable Cardiac Devices Be Used to Lower Risk of Stroke?
    Wasserlauf J.
    Passman R.S.
    Current Cardiovascular Risk Reports, 2017, 11 (10)
  • [5] Interaction of CaMKII and NaV1.8 modulates cardiac electrophysiology in human heart failure
    Tirilomis, P.
    Ahmad, S.
    Bengel, P.
    Pabel, S.
    Maier, L.
    Hasenfuss, G.
    Dybkova, N.
    Sossalla, S. T.
    EUROPEAN HEART JOURNAL, 2019, 40 : 898 - 898
  • [6] IMPLANTABLE MEDICAL DEVICES USED IN THE CARE OF CHILDREN WITH CONGENITAL HEART DISEASE
    Wunnava, Susmitha
    Miller, Timothy
    Bourgeois, Florence
    Nathan, Meena
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 1627 - 1627
  • [7] Cardiac MRI and Electrophysiology Study Can Risk Stratify Patients with Ventricular Tachycardia and Structurally Normal Heart
    Mathuria, Nilesh
    Michowitz, Yoav
    Moriarty, John
    Tung, Roderick
    Buch, Eric
    Bradfield, Jason
    Fujimura, Osamu
    Boyle, Noel
    Mandapati, Ravi
    Finn, J. Paul
    Cheng, Jie
    Shivkumar, Kalyanam
    CIRCULATION, 2012, 126 (21)
  • [8] A Different Aproach of Chronic Obstructive Pulmonary Disease Severity and Plastic Medical Devices Used for Oxygenotherapy
    Tofolean, Doina Ecaterina
    Popescu, Gilda
    Arghir, Ioan Anton
    Frandes, Mirela
    Fildan, Ariadna Petronela
    MATERIALE PLASTICE, 2019, 56 (02) : 295 - 300
  • [9] STUDIES OF THE INTERACTION OF CHEMICALS WITH MICROTUBULE ASSEMBLY INVITRO CAN BE USED AS AN ASSAY FOR DETECTION OF CYTO-TOXIC CHEMICALS AND POSSIBLE INDUCERS OF ANEUPLOIDY
    WALLIN, M
    FRIDEN, B
    BILLGER, M
    MUTATION RESEARCH, 1988, 201 (02): : 303 - 311
  • [10] You Can't Touch This: Potential Perils of Patient Interaction with Clinical Medical Devices
    Noble, Paul
    Blandford, Ann
    HUMAN-COMPUTER INTERACTION - INTERACT 2013, PT II, 2013, 8118 : 395 - 402