Pacemakers and implantable cardioverter-defibrillators in pediatric patients

被引:37
|
作者
Silka, Michael J. [1 ]
Bar-Cohen, Yaniv [1 ]
机构
[1] Univ So Calif, Childrens Hosp Los Angeles, Keck Sch Med, Dept Pediat,Div Cardiol, Los Angeles, CA 90027 USA
关键词
pacemaker; implantable cardioverter-defibrillatorchildren; pediatrics; congenital heart disease;
D O I
10.1016/j.hrthm.2006.02.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of pacemakers and implantable cardioverter-defibrillators (ICDs) in infants, children, and patients with congenital heart disease presents unique challenges and considerations. They include uncommon indications for device implantation, innovative approaches to lead implantation and configuration, and age-dependent and disease-specific aspects of device programming. In this review, the current indications for pacemaker and ICD implantation in young patients are discussed, followed by consideration of the approaches to lead and device placement in very small patients and those with complex congenital heart disease, in whom unique problems may be encountered. The limitations of programmability of current pacemakers and ICDs when used in young patients are discussed, followed by an analysis of long-term device follow-up and potential late complications.
引用
收藏
页码:1360 / 1366
页数:7
相关论文
共 50 条
  • [41] Beam profile disturbances from interactions with implantable pacemakers and implantable cardioverter-defibrillators
    Gossman, Michael S.
    Blohm, Christopher M.
    MEDICAL DOSIMETRY, 2013, 38 (02) : 109 - 109
  • [42] Summary of consesus statement on the management of patients with implantable pacemakers and cardioverter-defibrillators undergoing radiotherapy
    Necasova, Lucie
    Koniarova, Irena
    Kautzner, Josef
    Haman, Ludek
    Wichterle, Dan
    Sediva, Lucie
    Dolezel, Martin
    COR ET VASA, 2021, 63 (04) : 518 - 522
  • [43] Pacemakers and implantable cardioverter defibrillators
    Allen, M.
    ANAESTHESIA, 2006, 61 (09) : 883 - 890
  • [44] Pacemakers and implantable cardioverter defibrillators
    Rozner, M
    CRITICAL CARE MEDICINE, 2004, 32 (08) : 1809 - 1812
  • [45] Are Implantable Cardioverter-Defibrillators Indicated in Pediatric Ventricular Assist Device Patients?
    Bulic, A.
    Ceresnak, S.
    Dykes, J. C.
    Chen, S.
    Motonaga, K.
    Rosenthal, D. N.
    Almond, C. S.
    Kaufman, B. D.
    Hollander, S. A.
    Maeda, K.
    Laroussi, N. A.
    Hanisch, D.
    Trela, A. V.
    Murray, J. M.
    Dubin, A. M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S36 - S36
  • [46] Ventricular arrhythmias and cardiac arrest in atrial fibrillation patients with pacemakers and implantable cardioverter-defibrillators
    Fawzy, Ameenathul M.
    Bisson, Arnaud
    Bentounes, Sid A.
    Bodin, Alexandre
    Herbert, Julien
    Lip, Gregory Y. H.
    Fauchier, Laurent
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2023, 115 : 70 - 78
  • [47] The use of Implantable cardioverter-defibrillators in pediatric patients awaiting heart transplantation
    Dubin, AM
    Berul, CI
    Bevilacqua, LM
    Collins, KK
    Etheridge, SP
    Fenrich, AL
    Friedman, RA
    Hamilton, RM
    Schaffer, MS
    Shah, M
    Silka, MJ
    Van Hare, GF
    Kertesz, NJ
    JOURNAL OF CARDIAC FAILURE, 2003, 9 (05) : 375 - 379
  • [48] Management of recalled pacemakers and implantable cardioverter-defibrillators - A decision analysis model
    Amin, Mitesh S.
    Matchar, David B.
    Wood, Mark A.
    Ellenbogen, Kenneth A.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (04): : 412 - 420
  • [49] Salvage of Pacemakers and Automatic Implantable Cardioverter-Defibrillators Using Dermis Grafts
    Rudolph, Ross
    Smith, Michael R.
    Curtis, Guy P.
    ANNALS OF THORACIC SURGERY, 2011, 91 (02): : 452 - 456
  • [50] Do airport metal detectors interfere with implantable pacemakers or cardioverter-defibrillators?
    Kolb, C
    Schmieder, S
    Lehmann, G
    Zrenner, B
    Karch, MR
    Plewan, A
    Schmitt, C
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (11) : 2054 - 2059